RESUMO
OBJECTIVES: Quantification of 24 h-proteinuria is the gold standard for diagnosing, staging, and monitoring of patients with renal AL amyloidosis. However, 24 h-urine collection is cumbersome and may result in preanalytical error. In this prospective study, we investigated the role of urinary albumin/creatinine ratio (UACR) (cut-off: 300 mg/g) identifying renal involvement, evaluated a UACR-based staging system (UACR cut-off: 3,600 mg/g) and assessed whether UACR response (UACR decrease >30% without worsening in eGFR >25%) predicts renal outcome in 531 patients with newly-diagnosed AL amyloidosis. METHODS: From October 2013 paired 24 h-proteinuria and UACR (on first morning void) were measured in all newly-diagnosed patients with AL amyloidosis. Correlation between 24 h-proteinuria and UACR at baseline was assessed by Pearson's r test. Impact of UACR response on renal outcome was assessed in randomly created testing (n=354) and validation (n=177) cohorts. RESULTS: A strong linear correlation was found between 24 h-proteinuria and UACR at baseline (r=0.90; p<0.001). After a median follow-up of 31 months, 57 (11%) patients required dialysis. A UACR-based renal staging system identified three stages with significantly higher dialysis rate at 36 months comparing stage I with stage II and stage II with stage III. Achieving a renal response, according to a UACR-based criterion, resulted in lower dialysis rate in both testing and validation cohorts. CONCLUSIONS: UACR is a reliable marker for diagnosis, prognosis, and organ response assessment in renal AL amyloidosis and can reliably replace 24 h-proteinuria in clinical trials and individual patients' management.
Assuntos
Amiloidose de Cadeia Leve de Imunoglobulina , Albuminas , Albuminúria/diagnóstico , Albuminúria/urina , Creatinina/urina , Humanos , Amiloidose de Cadeia Leve de Imunoglobulina/diagnóstico , Testes de Função Renal , Estudos ProspectivosRESUMO
BACKGROUND: The measurement of circulating free light chain (FLC) is essential in the diagnosis, prognostic stratification and evaluation of response to therapy in light chain (AL) amyloidosis. For more than 10 years, this has been done with an immunonephelometric assay based on polyclonal antibodies (Freelite), and cutoffs for staging and response assessment have been validated with this method. Recently, a new assay based on monoclonal antibodies (N latex FLC) has been marketed in Europe. METHODS: We evaluated and compared the clinical performance of the two assays in 426 patients with newly diagnosed AL amyloidosis. RESULTS: We found suboptimal agreement between the two methods, with differences between values obtained with the Freelite and N latex FLC assays increasing with the concentration of clonal FLC. The diagnostic sensitivity of the Freelite (82%) and N latex FLC (84%) assays was similar, and both improved to 98% in combination with serum and urine immunofixation. The concentration of FLC measured with both methods had prognostic significance. Less pronounced decreases in FLC best predicted improved survival with the N latex FLC assay (33% vs. 50%), and there was poor concordance (84%) in discrimination of responders. CONCLUSIONS: The two assays have similar diagnostic and prognostic performance. However, they are not interchangeable, and follow-up should be done with either one. New response criteria are needed for the N latex FLC assay.