Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Invest Radiol ; 57(4): 212-221, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-34711766

RESUMO

OBJECTIVES: The aim of this study is to compare the image quality of in vivo coronary stents between an energy integrating detectors dual-layer computed tomography (EID-DLCT) and a clinical prototype of spectral photon counting computed tomography (SPCCT). MATERIALS AND METHODS: In January to June 2021, consecutive patients with coronary stents were prospectively enrolled to undergo a coronary computed tomography (CT) with an EID-DLCT (IQon, Philips) and an SPCCT (Philips). The study was approved by the local ethical committee and patients signed an informed consent. A retrospectively electrocardiogram-gated acquisition was performed with optimized matching parameters on the 2 scanners (EID-DLCT: collimation, 64 × 0.625 mm; kVp, 120, automatic exposure control with target current at 255 mAs; rotation time, 0.27 seconds; SPCCT: collimation, 64 × 0.275 mm; kVp, 120; mAs, 255; rotation time, 0.33 seconds). The injection protocol was the same on both scanners: 65 to 75 mL of Iomeron (Bracco) at 5 mL/s. Images were reconstructed with slice thickness of 0.67 mm, 512 matrix, XCB (Xres cardiac standard) and XCD (Xres cardiac detailed) kernel, iDose 3 for EID-DLCT and 0.25-mm slice thickness, 1024 matrix, Detailed 2 and Sharp kernel, and iDose 6 for SPCCT. Two experienced observers measured the proximal and distal external and internal diameters of the stents to quantify blooming artifacts. Regions of interest were drawn in the lumen of the stent and of the upstream coronary artery. The difference (Δ S-C) between the respective attenuation values was calculated as a quantification of stent-induced artifacts on intrastent image quality. For subjective image quality, 3 experienced observers graded with a 4-point scale the image quality of different parameters: coronary wall before the stent, stent lumen, stent structure, calcifications surrounding the stent, and beam-hardening artifacts. RESULTS: Eight patients (age, 68 years [interquartile range, 8]; all men; body mass index, 26.2 kg/m2 [interquartile range, 4.2]) with 16 stents were scanned. Five stents were not evaluable owing to motion artifacts on the SPCCT. Of the remaining, all were drug eluting stents, of which 6 were platinum-chromium, 3 were cobalt-platinum-iridium, and 1 was stainless steel. For 1 stent, no information could be retrieved. Radiation dose was lower with the SPCCT (fixed CT dose index of 25.7 mGy for SPCCT vs median CT dose index of 35.7 [IQ = 13.6] mGy; P = 0.02). For 1 stent, the internal diameter was not assessable on EID-DLCT. External diameters were smaller and internal diameters were larger with SPCCT (all P < 0.05). Consequently, blooming artifacts were reduced on SPCCT (P < 0.05). Whereas Hounsfield unit values within the coronary arteries on the 2 scanners were similar, the Δ S-C was lower for SPCCT-Sharp as compared with EID-DLCT-XCD and SPCCT-Detailed 2 (P < 0.05). The SPCCT received higher subjective scores than EID-DLCT for stent lumen, stent structure, surrounding calcifications and beam-hardening for both Detailed 2 and Sharp (all P ≤ 0.05). The SPCCT-Sharp was judged better for stent structure and beam-hardening assessment as compared with SPCCT-Detailed 2. CONCLUSION: Spectral photon counting CT demonstrated improved objective and subjective image quality as compared with EID-DLCT for the evaluation of coronary stents even with a reduced radiation dose.


Assuntos
Angiografia por Tomografia Computadorizada , Platina , Idoso , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Humanos , Masculino , Imagens de Fantasmas , Fótons , Estudos Retrospectivos , Stents , Tomografia Computadorizada por Raios X/métodos
2.
Diagnostics (Basel) ; 11(12)2021 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-34943611

RESUMO

AIMS: To evaluate spectral photon-counting CT's (SPCCT) objective image quality characteristics in vitro, compared with standard-of-care energy-integrating-detector (EID) CT. METHODS: We scanned a thorax phantom with a coronary artery module at 10 mGy on a prototype SPCCT and a clinical dual-layer EID-CT under various conditions of simulated patient size (small, medium, and large). We used filtered back-projection with a soft-tissue kernel. We assessed noise and contrast-dependent spatial resolution with noise power spectra (NPS) and target transfer functions (TTF), respectively. Detectability indices (d') of simulated non-calcified and lipid-rich atherosclerotic plaques were computed using the non-pre-whitening with eye filter model observer. RESULTS: SPCCT provided lower noise magnitude (9-38% lower NPS amplitude) and higher noise frequency peaks (sharper noise texture). Furthermore, SPCCT provided consistently higher spatial resolution (30-33% better TTF10). In the detectability analysis, SPCCT outperformed EID-CT in all investigated conditions, providing superior d'. SPCCT reached almost perfect detectability (AUC ≈ 95%) for simulated 0.5-mm-thick non-calcified plaques (for large-sized patients), whereas EID-CT had lower d' (AUC ≈ 75%). For lipid-rich atherosclerotic plaques, SPCCT achieved 85% AUC vs. 77.5% with EID-CT. CONCLUSIONS: SPCCT outperformed EID-CT in detecting simulated coronary atherosclerosis and might enhance diagnostic accuracy by providing lower noise magnitude, markedly improved spatial resolution, and superior lipid core detectability.

3.
Respir Res ; 22(1): 162, 2021 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-34030695

RESUMO

BACKGROUND: There is a paucity of data on the epidemiology, survival estimates and healthcare resource utilisation and associated costs of patients with progressive fibrosing interstitial lung disease (PF-ILD) in France. An algorithm for extracting claims data was developed to indirectly identify and describe patients with PF-ILD in the French national administrative healthcare database. METHODS: The French healthcare database, the Système National des Données de Santé (SNDS), includes data related to ambulatory care, hospitalisations and death for 98.8% of the population. In this study, algorithms based on age, diagnosis and healthcare consumption were created to identify adult patients with PF-ILD other than idiopathic pulmonary fibrosis between 2010 and 2017. Incidence, prevalence, survival estimates, clinical features and healthcare resource usage and costs were described among patients with PF-ILD. RESULTS: We identified a total of 14,413 patients with PF-ILD. Almost half of them (48.1%) were female and the mean (± standard deviation) age was 68.4 (± 15.0) years. Between 2010 and 2017, the estimated incidence of PF-ILD ranged from 4.0 to 4.7/100,000 person-years and the estimated prevalence from 6.6 to 19.4/100,000 persons. The main diagnostic categories represented were exposure-related ILD other than hypersensitivity pneumonitis (n = 3486; 24.2%), idiopathic interstitial pneumonia (n = 3113; 21.6%) and rheumatoid arthritis-associated ILD (n = 2521; 17.5%). Median overall survival using Kaplan-Meier estimation was 3.7 years from the start of progression. During the study, 95.2% of patients had ≥ 1 hospitalisation for respiratory care and 34.3% were hospitalised in an intensive care unit. The median (interquartile range) total specific cost per patient during the follow-up period was €25,613 (10,622-54,287) and the median annual cost per patient was €18,362 (6856-52,026), of which €11,784 (3003-42,097) was related to hospitalisations. Limitations included the retrospective design and identification of cases through an algorithm in the absence of chest high-resolution computed tomography scans and pulmonary function tests. CONCLUSIONS: This large, real-world, longitudinal study provides important insights into the characteristics, epidemiology and healthcare resource utilisation and costs associated with PF-ILD in France using a comprehensive and exhaustive database, and provides vital evidence that PF-ILD represents a high burden on both patients and healthcare services. Trial registration ClinicalTrials.gov, NCT03858842. ISRCTN, ISRCTN12345678. Registered 3 January 2019-Retrospectively registered, https://clinicaltrials.gov/ct2/show/NCT03858842.


Assuntos
Doenças Pulmonares Intersticiais/epidemiologia , Fibrose Pulmonar/epidemiologia , Demandas Administrativas em Assistência à Saúde , Idoso , Idoso de 80 Anos ou mais , Causas de Morte , Efeitos Psicossociais da Doença , Bases de Dados Factuais , Progressão da Doença , Feminino , França/epidemiologia , Custos Hospitalares , Humanos , Incidência , Estudos Longitudinais , Doenças Pulmonares Intersticiais/diagnóstico , Doenças Pulmonares Intersticiais/mortalidade , Doenças Pulmonares Intersticiais/terapia , Masculino , Pessoa de Meia-Idade , Prevalência , Prognóstico , Fibrose Pulmonar/diagnóstico , Fibrose Pulmonar/mortalidade , Fibrose Pulmonar/terapia , Estudos Retrospectivos , Fatores de Tempo
4.
Eur Radiol ; 30(1): 425-431, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31332557

RESUMO

OBJECTIVES: To assess the capability of a newly developed material decomposition method from contrast-enhanced dual-energy CT images, aiming to better visualize the aortic wall and aortic intramural hematoma (IMH), compared with true non-contrast (TNC) CT. MATERIALS AND METHODS: Twenty-two patients (11 women; mean age, 61 ± 20 years) with acute chest pain underwent 25 dual-layer non-contrast and contrast-enhanced CT. CT-angiography images were retrospectively processed using two-material decomposition analysis, where we defined the first material as the content of a region of interest placed in the ascending aorta for each patient, and the second material as water. Two independent radiologists assessed the images from the second material termed "dark-blood" images and the TNC images regarding contrast-to-noise ratio (CNR) between the wall and the lumen, diagnostic quality regarding the presence of aortic wall thickening, and the inner/outer vessel wall conspicuity. RESULTS: Diagnostic quality scores in normal aortic segments were 0.9 ± 0.3 and 2.7 ± 0.6 (p < 0.001) and wall conspicuity scores were 0.7 ± 0.5 and 1.8 ± 0.3 (p < 0.001) on TNC and dark-blood images, respectively. In aortic segments with IMH, diagnostic quality scores were 1.7 ± 0.5 and 2.4 ± 0.6 (p < 0.001) and wall conspicuity scores were 0.7 ± 0.7 and 1.8 ± 0.3 (p < 0.001) on TNC and dark-blood images, respectively. In normal aortic segments, CNRs were 0.3 ± 0.2 and 2.8 ± 0.9 on TNC and dark-blood images, respectively (p < 0.001). In aortic segments with IMH, CNRs were 0.3 ± 0.2 and 4.0 ± 1.0 on TNC and dark-blood images, respectively (p < 0.001). CONCLUSIONS: Compared with true non-contrast CT, dark-blood material decomposition maps enhance quantitative and qualitative image quality for the assessment of normal aortic wall and IMH. KEY POINTS: • Current dual-energy CT-angiography provides virtual non-contrast and bright-blood images. • Dark-blood images represent a new way to assess the vascular wall structure with dual-energy CT and can improve the lumen-to-wall contrast compared with true non-contrast CT. • This dual-energy CT material decomposition method is likely to improve contrast resolution in other applications as well, taking advantage of the high spatial resolution of CT.


Assuntos
Aorta Torácica/diagnóstico por imagem , Doenças da Aorta/diagnóstico por imagem , Hematoma/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
6.
Magn Reson Imaging ; 30(10): 1424-31, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22835940

RESUMO

PURPOSE: To assess the sensitivity and specificity of intra-plaque hemorrhage (IPH), large lipid-rich necrotic core (LR-NC) and ulceration or cap rupture (UCR) for symptomatic carotid plaque characterization and to evaluate a new imaging score [Hemorrhage, Ulceration or cap rupture, Lipid-rich necrotic Core (HULC) score based on the sum of presence/absence of IPH, UCR and LR-NC; range 0-3] for assessment of recently symptomatic carotid plaques. MATERIAL AND METHODS: Twenty-seven recently symptomatic (<8 weeks) and 36 asymptomatic patients with a carotid plaque thicker than 2 mm were prospectively imaged on a 3-T magnetic resonance (MR) system using high-resolution, multi-contrast MR sequences. Prior to analysis, all images were reviewed to assess image quality of each sequence. Sensitivity and specificity of IPH, LR-NC, UCR and HULC scores were calculated. RESULTS: Fifty-one patients were analyzed (26 symptomatic carotids and 67 asymptomatic carotids) after exclusion of studies with poor image quality. Sensitivity and specificity for symptomatic carotid plaque was, respectively, 46.1% and 97% for IPH, 84.6% and 73.1% for UCR and 80.7% and 76.1% for LR-NC. A HULC score of 2 or more showed a sensitivity of 73% and a specificity of 92.5%. CONCLUSION: At 3 T, intra-plaque hemorrhage is the most specific criterion to characterize symptomatic carotid plaque. The HULC score offers the best compromise between sensitivity and specificity.


Assuntos
Estenose das Carótidas/patologia , Imageamento por Ressonância Magnética/métodos , Placa Aterosclerótica/diagnóstico , Placa Aterosclerótica/patologia , Idoso , Aterosclerose/patologia , Índice de Massa Corporal , Feminino , Hemorragia/metabolismo , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Necrose , Sensibilidade e Especificidade
7.
J Magn Reson Imaging ; 32(5): 1110-6, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21031516

RESUMO

PURPOSE: To assess the capability of four-dimensional (4D) time-resolved magnetic resonance angiography (MRA) to assess pulmonary arteriovenous malformations (PAVMs) patency by analyzing pulmonary arterial and venous enhancement kinetics. MATERIALS AND METHODS: Seven patients with eight documented patent PAVMs underwent a 4D-MRA with keyhole and viewsharing compression at 3T with the following parameters: spatial resolution 0.87 × 0.87 × 1.4 mm(3); field of view 500 × 350 × 238 mm(3); dynamic scan time (temporal resolution) 1.2 seconds; total acquisition time 18.1 seconds for six dynamic datasets (6 × 1.2 sec + reference scan: 10.9 sec). All images were reviewed by two experienced radiologists. Image quality was rated on a qualitative 5-point scale (1: not assessable to 5: excellent). Signal value was measured on cross-sectional planes for the afferent arteries and efferent veins of the PAVM, and for normal reference healthy arteries and veins. The difference in time to peak for each coupled artery/vein (dTTPav) was calculated and compared with a Mann-Whitney test between PAVMs and reference vessels. RESULTS: Mean image quality was 3.2 ± 0.9. dTTPav was significantly smaller in PAVMs (0.15 ± 0.76 sec) than in reference vessels (3.75 ± 1.62 sec), P < 0.001. CONCLUSION: 4D-MRA is a promising tool for noninvasive assessment of PAVM patency.


Assuntos
Malformações Arteriovenosas/diagnóstico , Angiografia por Ressonância Magnética/métodos , Artéria Pulmonar/anormalidades , Veias Pulmonares/anormalidades , Idoso , Malformações Arteriovenosas/terapia , Embolização Terapêutica , Humanos , Pessoa de Meia-Idade , Telangiectasia Hemorrágica Hereditária/complicações , Grau de Desobstrução Vascular , Adulto Jovem
8.
Arch Cardiovasc Dis ; 102(8-9): 607-15, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19786264

RESUMO

BACKGROUND: There is a need to identify diabetic patients at risk of cardiovascular events before symptom onset. AIMS: To evaluate the prevalence and characteristics of coronary atherosclerotic plaques in asymptomatic type 2 diabetic patients with coronary risk factors but without known coronary artery disease, using multidetector computed tomography. METHODS: High-resolution 40-slice coronary computed tomography was performed prospectively in 42 consecutive type 2 diabetic patients (mean age 62 years; range 50-77 years; 28 men) with over one or more carotid atherosclerotic plaque and no coronary artery disease symptoms. Computed tomography data were evaluated for calcium score and the presence of coronary plaques. Plaque type, distribution, extensive character and obstructive nature were determined per patient for each segment. RESULTS: No plaques were detected in 11 (26.2%) patients. Atherosclerotic plaques were detected in 31 (73.8%) patients. A total of 147 coronary segments with plaque were identified, of which 11 (7.5%) contained hypodense plaques, 28 (19%) mixed plaques and 108 (73.5%) calcified plaques. Hypodense plaques were noted in 4/15 (26.7%) patients without coronary calcifications. Most calcified and hypodense plaques resulted in lumen narrowing of less than 50%; most mixed plaques resulted in lumen narrowing greater than 50%. Obstructive disease was detected in 9/11 patients with a high calcium score (>400). CONCLUSION: This preliminary study demonstrates that a high proportion of asymptomatic type 2 diabetic patients present without coronary plaques detectable by multidetector computed tomography, despite concomitant carotid atherosclerotic lesions. Computed tomography seems to detect a high proportion of plaques compared with conventional angiography in these specific patients.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Diabetes Mellitus Tipo 2/diagnóstico por imagem , Angiopatias Diabéticas/diagnóstico por imagem , Tomografia Computadorizada Espiral , Idoso , Calcinose/diagnóstico por imagem , Calcinose/etiologia , Doenças das Artérias Carótidas/diagnóstico por imagem , Doenças das Artérias Carótidas/etiologia , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/etiologia , Estudos Transversais , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/epidemiologia , Angiopatias Diabéticas/epidemiologia , Angiopatias Diabéticas/etiologia , Humanos , Pessoa de Meia-Idade , Projetos Piloto , Valor Preditivo dos Testes , Prevalência , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador , Medição de Risco , Índice de Gravidade de Doença
9.
Invest Radiol ; 43(11): 773-81, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18923256

RESUMO

OBJECTIVES: (1) To determine the accuracy of delayed enhancement multidetector computed tomography (MDCT) in measuring the extent of acute myocardial infarct and no-reflow areas using cardiac magnetic resonance imaging (MRI) as standard of reference and (2) to define the optimum timing between injection and MDCT image acquisition to characterize infarcted myocardium and no-reflow areas after reperfusion therapy. MATERIALS AND METHODS: Nineteen patients were prospectively included after acute myocardial infarction and revascularization. Each patient had an MDCT acquisition before and 5 and 10 minutes after injection of 1.5 mL/kg iodinated contrast medium, and a contrast-enhanced MRI at 5 and 10 minutes after injection of 0.2 mmol/kg gadolinium chelate. We assessed image quality and infarct extent using MDCT and MRI, and we measured parameters related to iodinated contrast media kinetics (DeltaHU and DeltaHU ratio). RESULTS: The areas of hyperenhanced myocardium located on the MDCT corresponded to the occluded vessel located on the coronary angiogram (kappa = 0.9). There were strong correlations between the extent of hyperenhanced infarcted myocardium on MDCT and MRI at 5 minutes (20.4% +/- 2.7% of left ventricle (LV) and 20.9% +/- 2.4%, respectively, R = 0.85; P < 0.0001) and 10 minutes after injection (21.0% +/- 2.9% of LV and 19.4% +/- 2.5%, respectively, R = 0.80; P < 0.0001). However, the correlation between the area of hypoenhanced myocardium measured using MDCT and CMR 5 minutes after injection (R = 0.86; P < 0.0001) was better than the measurement obtained 10 minutes after injection (R = 0.64; P = 0.002). On contrast-enhanced MDCT, 5 minutes after injection, the signal-to-noise ratio was significantly higher than at 10 minutes after injection in LV blood (28 +/- 1 to 21 +/- 1, respectively; P = 0.0007), normal myocardium (18 +/- 1 to 15 +/- 1; P = 0.0009), and hyperenhanced infarcted myocardium (24 +/- 1 to 20 +/- 1; P = 0.004). MDCT image quality was significantly better at 5 minutes (3.2 +/- 0.1) than at 10 minutes (2.8 +/- 0.2, P = 0.01, kappa = 0.4). The DeltaHU ratio increased slightly but significantly between 5 minutes (0.83 +/- 0.01) and 10 minutes (0.93 +/- 0.01; P = 0.01), suggesting a slow wash-in and wash-out of contrast medium in infarcted myocardium. CONCLUSION: In ST segment elevation myocardial infarction patients contrast-enhanced MDCT is an accurate method for characterizing and sizing myocardial infarct and no-reflow. Contrast-enhanced MDCT performed 5 minutes after injection yields a higher signal-to-noise ratio and image quality than the 10 minutes time point with no difference in the extent of infarct measurement.


Assuntos
Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/terapia , Reperfusão/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fenômeno de não Refluxo/diagnóstico , Fenômeno de não Refluxo/prevenção & controle , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
10.
AJR Am J Roentgenol ; 191(2): 441-7, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18647915

RESUMO

OBJECTIVE: Imaging to determine myocardial infarct size is difficult in the emergency setting because the current gold standards, MRI and nuclear medicine techniques, are difficult to perform in unstable patients. Delayed enhanced MDCT has recently been proposed as a technique to study contrast uptake in infarcted myocardium. In this study, we compared the extent of acute myocardial infarction as measured by delayed enhanced MDCT performed immediately after percutaneous coronary intervention (PCI) without an additional iodine injection with that measured by delayed gadolinium-enhanced MRI. SUBJECTS AND METHODS: Nineteen consecutive patients presenting with primary acute myocardial infarction underwent delayed enhanced MDCT immediately after coronary angioplasty and underwent delayed enhanced MRI within 8 days of angioplasty. Only patients with a thrombolysis in myocardial infarction (TIMI) score of 0 or 1 of the culprit coronary artery before endovascular angioplasty and TIMI score of 2 or 3 after angioplasty were selected. Comparison of delayed enhanced MDCT and delayed enhanced MRI was performed by three observers and focused on identifying the involved segments and determining the transmural extent of enhancement and infarct size. RESULTS: The mean signal intensity was significantly higher in the involved territory than in healthy myocardium: 197 +/- 81 H versus 71 +/- 20 H, respectively (p < 0.0001). We found significant agreement between delayed enhanced MDCT and delayed enhanced MRI for the number of involved segments, transmural extent of enhancement, and infarct size (r(2) = 0.74, 0.76, and 0.67, respectively; p < 0.0001) with good interobserver reproducibility (kappa = 0.8). CONCLUSION: The results of our study show that delayed enhanced MDCT allows accurate visualization of early myocardial contrast uptake compared with delayed enhanced MRI and does not require an additional contrast injection after PCI.


Assuntos
Angioplastia com Balão , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/patologia , Infarto do Miocárdio/terapia , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Meios de Contraste , Feminino , Compostos Heterocíclicos , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos , Reprodutibilidade dos Testes , Resultado do Tratamento
11.
Eur J Cardiothorac Surg ; 33(1): 53-7, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18054246

RESUMO

PURPOSE: It is essential to evaluate new stent designs before in vivo testing. The purpose of this study was to develop and validate a controlled and reproducible patient-derived process to produce a life-size in vitro model of aortic arch aneurysm for endovascular procedure simulation. METHODS: A three-dimensional magnetic resonance angiography (3D MRA) image derived from a 60-year-old patient with aortic arch aneurysm was segmented using a home-made software package which allows one-click automatic segmentation of the aorta, meshing, and conversion to standard tessellation language (STL) format. A rapid prototyping technique established a stereolithographic model to produce a replica of the whole aorta, including the arch aneurysm and supra-aortic arteries. RESULTS: The final model was made by pouring silicone rubber to obtain a sturdy, life-size, soft, transparent, plastic cast, accurately reproducing both the internal and external anatomy of the aortic aneurysm. This model was used under perfusion by an extracorporeal circulation pump, to test ex vivo stent deployment. CONCLUSION: The combination of easy segmentation and conversion to the STL format with industrial stereolithography techniques enabled a realistic silicon vascular phantom to be created for endovascular procedure simulation, image modality calibration, and new stent design.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/educação , Angiografia por Ressonância Magnética/métodos , Modelos Anatômicos , Simulação por Computador , Humanos , Angiografia por Ressonância Magnética/normas , Desenho de Prótese/normas , Elastômeros de Silicone
12.
J Digit Imaging ; 20(2): 122-30, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17333414

RESUMO

DicomWorks is freeware software for reading and working on medical images [digital imaging and communication in medicine (DICOM)]. It was jointly developed by two research laboratories, with the feedback of more than 35,000 registered users throughout the world who provided information to guide its development. We detail their occupations (50% radiologists, 20% engineers, 9% medical physicists, 7% cardiologists, 6% neurologists, and 8% others), geographic origins, and main interests in the software. The viewer's interface is similar to that of a picture archiving and communication system viewing station. It provides basic but efficient tools for opening DICOM images and reviewing and exporting them to teaching files or digital presentations. E-mail, FTP, or DICOM protocols are supported for transmitting images through a local network or the Internet. Thanks to its wide compatibility, a localized (15 languages) and user-friendly interface, and its opened architecture, DicomWorks helps quick development of non proprietary, low-cost image review or teleradiology solutions in developed and emerging countries.


Assuntos
Diagnóstico por Imagem , Sistemas de Informação em Radiologia , Software , Telerradiologia , Sistemas Computacionais , Apresentação de Dados , Sistemas de Gerenciamento de Base de Dados , Correio Eletrônico , Humanos , Processamento de Imagem Assistida por Computador , Armazenamento e Recuperação da Informação , Internet , Redes Locais , Sistemas de Informação em Radiologia/economia , Design de Software , Telerradiologia/economia , Interface Usuário-Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA