The cerebral pressure reactivity index (PRx), through intracranial pressure (ICP) measurements, informs clinicians about the cerebral autoregulation (CA) status in adult-sedated patients with traumatic brain injury (TBI). Using PRx in clinical practice is currently limited by variability over shorter monitoring periods. We applied an innovative method to reduce the PRx variability by ventilator-induced slow (1/min) positive end-expiratory pressure (PEEP) oscillations. We hypothesized that, as seen in a previous animal model, the PRx variability would be reduced by inducing slow arterial blood pressure (ABP) and ICP oscillations without other clinically relevant physiological changes. Patients with TBI were ventilated with a static PEEP for 30 min (PRx period) followed by a 30-min period of slow [1/min (0.0167 Hz)] +5 cmH2O PEEP oscillations (induced (iPRx period). Ten patients with TBI were included. No clinical monitoring was discontinued and no additional interventions were required during the iPRx period. The PRx variability [measured as the standard deviation (SD) of PRx] decreased significantly during the iPRx period from 0.25 (0.22-0.30) to 0.14 (0.09-0.17) (P = 0.006). There was a power increase around the induced frequency (1/min) for both ABP and ICP (P = 0.002). In conclusion, 1/min PEEP-induced oscillations reduced the PRx variability in patients with TBI with ICP levels <22 mmHg. No other clinically relevant physiological changes were observed. Reduced PRx variability might improve CA-guided perfusion management by reducing the time to find "optimal" perfusion pressure targets. Larger studies with prolonged periods of PEEP-induced oscillations are required to take it to routine use.NEW & NOTEWORTHY Cerebral autoregulation assessment requires sufficient slow arterial blood pressure (ABP) waves. However, spontaneous ABP waves may be insufficient for reliable cerebral autoregulation estimations. Therefore, we applied a ventilator "sigh-function" to generate positive end-expiratory pressure oscillations that induce slow ABP waves. This method demonstrated a reduced variability of the pressure reactivity index, commonly used as continuous cerebral autoregulation measure in a traumatic brain injury population.


Assuntos
Lesões Encefálicas Traumáticas , Lesões Encefálicas , Animais , Pressão Arterial/fisiologia , Circulação Cerebrovascular/fisiologia , Pressão Intracraniana/fisiologia , Respiração com Pressão Positiva
2.
J Cereb Blood Flow Metab ; 35(2): 248-56, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25407266

RESUMO

The impulse response (IR)-based autoregulation index (ARI) allows for continuous monitoring of cerebral autoregulation using spontaneous fluctuations of arterial blood pressure (ABP) and cerebral flow velocity (FV). We compared three methods of autoregulation assessment in 288 traumatic brain injury (TBI) patients managed in the Neurocritical Care Unit: (1) IR-based ARI; (2) transfer function (TF) phase, gain, and coherence; and (3) mean flow index (Mx). Autoregulation index was calculated using the TF estimation (Welch method) and classified according to the original Tiecks' model. Mx was calculated as a correlation coefficient between 10-second averages of ABP and FV using a moving 300-second data window. Transfer function phase, gain, and coherence were extracted in the very low frequency (VLF, 0 to 0.05 Hz) and low frequency (LF, 0.05 to 0.15 Hz) bandwidths. We studied the relationship between these parameters and also compared them with patients' Glasgow outcome score. The calculations were performed using both cerebral perfusion pressure (CPP; suffix 'c') as input and ABP (suffix 'a'). The result showed a significant relationship between ARI and Mx when using either ABP (r=-0.38, P<0.001) or CPP (r=-0.404, P<0.001) as input. Transfer function phase and coherence_a were significantly correlated with ARI_a and ARI_c (P<0.05). Only ARI_a, ARI_c, Mx_a, Mx_c, and phase_c were significantly correlated with patients' outcome, with Mx_c showing the strongest association.


Assuntos
Pressão Sanguínea , Lesões Encefálicas , Circulação Cerebrovascular , Homeostase , Modelos Cardiovasculares , Adolescente , Adulto , Velocidade do Fluxo Sanguíneo , Lesões Encefálicas/diagnóstico por imagem , Lesões Encefálicas/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Ultrassonografia Doppler Transcraniana