Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Analyst ; 148(9): 2133-2140, 2023 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-37039548

RESUMO

An auto titrator system was developed to accurately and precisely detect colorimetric endpoints for spectrochemical titrations. This system was constructed using inexpensive components such as a Raspberry Pi® single-board computer, 3D-printed components, and a commercially available spectral sensor. The auto titrator was evaluated by performing a standard method for determination of water hardness. Regardless of analyst experience, the auto titrator performed better than the traditional titration approach that involves manual dosing of titrant and visual detection of the endpoint. Inter-day, intra-day, inter-instrumental, and intra-instrumental validation studies were performed to establish the accuracy and precision of endpoint detection. The auto titrator eliminates the subjective bias in color perception and produces accurate and precise endpoint results.


Assuntos
Colorimetria , Água , Colorimetria/métodos , Titulometria/métodos
2.
J Cardiovasc Magn Reson ; 12: 44, 2010 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-20663157

RESUMO

BACKGROUND: Many adult patients with secundum-type atrial septal defects (ASDs) are able to have these defects fixed percutaneously. Traditionally, this has involved an assessment of ASD size, geometry and atrial septal margins by transoesophageal echocardiography (TOE) prior to percutaneous closure. This is a semi-invasive technique, and all of the information obtained could potentially be obtained by non-invasive cardiovascular magnetic resonance (CMR). We compared the assessment of ASDs in consecutive patients being considered for percutaneous ASD closure using CMR and TOE. METHODS: Consecutive patients with ASDs diagnosed on transthoracic echocardiography (TTE) were invited to undergo both CMR and TOE. Assessment of atrial septal margins, maximal and minimal defect dimensions was performed with both techniques. Analyses between CMR and TOE were made using simple linear regression and Bland Altman Analyses. RESULTS: Total CMR scan time was 20 minutes, and comparable to the TOE examination time. A total of 20 patients (M:F = 5:15, mean age 42.8 years +/- 15.7) were included in the analyses. There was an excellent agreement between CMR and TOE for estimation of maximum defect size (R = 0.87). The anterior inferior, anterior superior and posterior inferior margins could be assessed in all patients with CMR. The posterior superior margin could not be assessed in only one patient. Furthermore, in 1 patient in whom TOE was unable to be performed, CMR was used to successfully direct percutaneous ASD closure. CONCLUSIONS: CMR agrees with TOE assessment of ASDs in the work-up for percutaneous closure. Potentially CMR could be used instead of TOE for this purpose.


Assuntos
Ecocardiografia Transesofagiana , Comunicação Interatrial/diagnóstico , Imageamento por Ressonância Magnética/métodos , Adulto , Feminino , Comunicação Interatrial/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade
3.
Heart Lung Circ ; 17(4): 313-7, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18314390

RESUMO

Cardiac magnetic resonance imaging (MRI) is being utilised increasingly for the purposes of cardiovascular imaging. Limited data suggest a high degree of reproducibility for parameters such as left ventricular (LV) ejection fraction (EF), mass, end-diastolic and end-systolic volumes (EDV and ESV). We sought to investigate reproducibility and establish means for these parameters in a selected normal non-Aboriginal Australian population, using cardiac MRI. Sixty normal volunteers underwent cardiac MRI investigation using a 1.5 T MRI system. Steady state free precession imaging was performed with short axis cine images through the left ventricle obtained. All images were acquired with cardiac gating. Two independent observers then analysed the data set. Data were collected for assessment of left ventricular EF, EDV, ESV, mass and right ventricular volumes. Data are presented as mean+/-S.D. Total imaging time was approximately 15 min. All patients were able to complete the full protocol. Left ventricular parameters: EF 58.5+/-8.0%, LV mass 114.2+/-40.6g, EDV 117.3+/-33.4 mls and ESV 50.0+/-22.2 mls. Right ventricular parameters: EF 45.6+/-11.6%, EDV 163.5+/-52.2 mls and ESV 89.5+/-34.3 mls. Intraclass correlation coefficients for LV: EF 0.84, LV mass 0.84, EDV 0.85 and ESV 0.89. Cardiac MRI provides high quality information about cardiac function with a high level of reproducibility. Cardiac MRI parameters in a normal non-Aboriginal Australian population are provided.


Assuntos
Imageamento por Ressonância Magnética , Função Ventricular Esquerda/fisiologia , Função Ventricular Direita/fisiologia , Adulto , Austrália , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA