JAMA Netw Open ; 7(4): e246548, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38639939

RESUMO

Importance: Unintended tumor-positive resection margins occur frequently during minimally invasive surgery for colorectal liver metastases and potentially negatively influence oncologic outcomes. Objective: To assess whether indocyanine green (ICG)-fluorescence-guided surgery is associated with achieving a higher radical resection rate in minimally invasive colorectal liver metastasis surgery and to assess the accuracy of ICG fluorescence for predicting the resection margin status. Design, Setting, and Participants: The MIMIC (Minimally Invasive, Indocyanine-Guided Metastasectomy in Patients With Colorectal Liver Metastases) trial was designed as a prospective single-arm multicenter cohort study in 8 Dutch liver surgery centers. Patients were scheduled to undergo minimally invasive (laparoscopic or robot-assisted) resections of colorectal liver metastases between September 1, 2018, and June 30, 2021. Exposures: All patients received a single intravenous bolus of 10 mg of ICG 24 hours prior to surgery. During surgery, ICG-fluorescence imaging was used as an adjunct to ultrasonography and regular laparoscopy to guide and assess the resection margin in real time. The ICG-fluorescence imaging was performed during and after liver parenchymal transection to enable real-time assessment of the tumor margin. Absence of ICG fluorescence was favorable both during transection and in the tumor bed directly after resection. Main Outcomes and Measures: The primary outcome measure was the radical (R0) resection rate, defined by the percentage of colorectal liver metastases resected with at least a 1 mm distance between the tumor and resection plane. Secondary outcomes were the accuracy of ICG fluorescence in detecting margin-positive (R1; <1 mm margin) resections and the change in surgical management. Results: In total, 225 patients were enrolled, of whom 201 (116 [57.7%] male; median age, 65 [IQR, 57-72] years) with 316 histologically proven colorectal liver metastases were included in the final analysis. The overall R0 resection rate was 92.4%. Re-resection of ICG-fluorescent tissue in the resection cavity was associated with a 5.0% increase in the R0 percentage (from 87.4% to 92.4%; P < .001). The sensitivity and specificity for real-time resection margin assessment were 60% and 90%, respectively (area under the receiver operating characteristic curve, 0.751; 95% CI, 0.668-0.833), with a positive predictive value of 54% and a negative predictive value of 92%. After training and proctoring of the first procedures, participating centers that were new to the technique had a comparable false-positive rate for predicting R1 resections during the first 10 procedures (odds ratio, 1.36; 95% CI, 0.44-4.24). The ICG-fluorescence imaging was associated with changes in intraoperative surgical management in 56 (27.9%) of the patients. Conclusions and Relevance: In this multicenter prospective cohort study, ICG-fluorescence imaging was associated with an increased rate of tumor margin-negative resection and changes in surgical management in more than one-quarter of the patients. The absence of ICG fluorescence during liver parenchymal transection predicted an R0 resection with 92% accuracy. These results suggest that use of ICG fluorescence may provide real-time feedback of the tumor margin and a higher rate of complete oncologic resection.


Assuntos
Neoplasias Colorretais , Neoplasias Hepáticas , Idoso , Feminino , Humanos , Masculino , Estudos de Coortes , Neoplasias Colorretais/cirurgia , Neoplasias Colorretais/patologia , Verde de Indocianina , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/patologia , Margens de Excisão , Imagem Óptica/métodos , Estudos Prospectivos , Pessoa de Meia-Idade
2.
Surg Endosc ; 37(9): 6824-6833, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37286750

RESUMO

BACKGROUND: Indocyanine green near-infrared fluorescence bowel perfusion assessment has shown its potential benefit in preventing anastomotic leakage. However, the surgeon's subjective visual interpretation of the fluorescence signal limits the validity and reproducibility of the technique. Therefore, this study aimed to identify objective quantified bowel perfusion patterns in patients undergoing colorectal surgery using a standardized imaging protocol. METHOD: A standardized fluorescence video was recorded. Postoperatively, the fluorescence videos were quantified by drawing contiguous region of interests (ROIs) on the bowel. For each ROI, a time-intensity curve was plotted from which perfusion parameters (n = 10) were derived and analyzed. Furthermore, the inter-observer agreement of the surgeon's subjective interpretation of the fluorescence signal was assessed. RESULTS: Twenty patients who underwent colorectal surgery were included in the study. Based on the quantified time-intensity curves, three different perfusion patterns were identified. Similar for both the ileum and colon, perfusion pattern 1 had a steep inflow that reached its peak fluorescence intensity rapidly, followed by a steep outflow. Perfusion pattern 2 had a relatively flat outflow slope immediately followed by its plateau phase. Perfusion pattern 3 only reached its peak fluorescence intensity after 3 min with a slow inflow gradient preceding it. The inter-observer agreement was poor-moderate (Intraclass Correlation Coefficient (ICC): 0.378, 95% CI 0.210-0.579). CONCLUSION: This study showed that quantification of bowel perfusion is a feasible method to differentiate between different perfusion patterns. In addition, the poor-moderate inter-observer agreement of the subjective interpretation of the fluorescence signal between surgeons emphasizes the need for objective quantification.


Assuntos
Neoplasias Colorretais , Cirurgia Colorretal , Humanos , Verde de Indocianina , Neoplasias Colorretais/cirurgia , Anastomose Cirúrgica/métodos , Cirurgia Colorretal/métodos , Reprodutibilidade dos Testes , Fístula Anastomótica/prevenção & controle , Perfusão
3.
Toxicol Res (Camb) ; 11(3): 511-519, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35782644

RESUMO

A follow-up study was performed in 12 healthy women to evaluate systemic exposure to aluminium following topical application of a representative antiperspirant formulation under real-life use conditions (part A) and to assess the local fate of topically applied aluminium by taking additional tape strips and skin biopsies (Part B). A simple roll-on formulation, containing the maximal possible radioactive dose, was prepared with [26Al] aluminium-labeled chlorohydrate (ACH). The microtracer of [26Al] was used to distinguish aluminium from the natural background, using accelerator mass spectrometry. [26Al] aluminiumcitrate was administered intravenously to estimate the dermal fraction absorbed. Despite the 25-fold increase of the topical dose compared with the previous study, only 12 blood samples gave results above the lower limit of quantitation (0.118 fg/mL). The most reliable estimates of the dermal fraction absorbed are derived from noncompartmental analysis with the urine data. By using the intravenous dose to normalize the urinary excretion to 100% bioavailability, the best estimate of the fraction absorbed of [26Al] from a topical application of [26Al]-aluminium-labeled chlorohydrate in an antiperspirant formulation was 0.00052%. Part B of the study demonstrated that the majority of the aluminium in the formulation remained associated with the external layers of the skin without penetration through the skin.

4.
Clin Cancer Res ; 26(15): 3990-3998, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32345649

RESUMO

PURPOSE: Incomplete oncologic resections and damage to vital structures during colorectal cancer surgery increases morbidity and mortality. Moreover, neoadjuvant chemoradiotherapy has become the standard treatment modality for locally advanced rectal cancer, where subsequent downstaging can make identification of the primary tumor more challenging during surgery. Near-infrared (NIR) fluorescence imaging can aid surgeons by providing real-time visualization of tumors and vital structures during surgery. EXPERIMENTAL DESIGN: We present the first-in-human clinical experience of a novel NIR fluorescent peptide, cRGD-ZW800-1, for the detection of colon cancer. cRGD-ZW800-1 was engineered to have an overall zwitterionic chemical structure and neutral charge to lower nonspecific uptake and thus background fluorescent signal. We performed a phase I study in 11 healthy volunteer as well as a phase II feasibility study in 12 patients undergoing an elective colon resection, assessing 0.005, 0.015, and 0.05 mg/kg cRGD-ZW800-1 for the intraoperative visualization of colon cancer. RESULTS: cRGD-ZW800-1 appears safe, and exhibited rapid elimination into urine after a single low intravenous dose. Minimal invasive intraoperative visualization of colon cancer through full-thickness bowel wall was possible after an intravenous bolus injection of 0.05 mg/kg at least 2 hours prior to surgery. Longer intervals between injection and imaging improved the tumor-to-background ratio. CONCLUSIONS: cRGD-ZW800-1 enabled fluorescence imaging of colon cancer in both open and minimal invasive surgeries. Further development of cRGD-ZW800-1 for widespread use in cancer surgery may be warranted given the ubiquitous overexpression of various integrins on different types of tumors and their vasculature.


Assuntos
Carcinoma/diagnóstico , Colo/diagnóstico por imagem , Neoplasias do Colo/diagnóstico , Corantes Fluorescentes/administração & dosagem , Imagem Óptica/métodos , Idoso , Idoso de 80 Anos ou mais , Animais , Carcinoma/patologia , Carcinoma/terapia , Quimiorradioterapia Adjuvante , Colectomia/métodos , Colo/patologia , Colo/cirurgia , Neoplasias do Colo/patologia , Neoplasias do Colo/terapia , Estudos de Viabilidade , Feminino , Corantes Fluorescentes/efeitos adversos , Corantes Fluorescentes/química , Corantes Fluorescentes/farmacocinética , Voluntários Saudáveis , Humanos , Integrinas/metabolismo , Masculino , Camundongos , Pessoa de Meia-Idade , Terapia Neoadjuvante , Imagem Óptica/efeitos adversos , Peptídeos Cíclicos/administração & dosagem , Peptídeos Cíclicos/efeitos adversos , Peptídeos Cíclicos/química , Peptídeos Cíclicos/farmacocinética , Compostos de Amônio Quaternário/administração & dosagem , Compostos de Amônio Quaternário/efeitos adversos , Compostos de Amônio Quaternário/química , Compostos de Amônio Quaternário/farmacocinética , Ratos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Ácidos Sulfônicos/administração & dosagem , Ácidos Sulfônicos/efeitos adversos , Ácidos Sulfônicos/química , Ácidos Sulfônicos/farmacocinética , Testes de Toxicidade Aguda
5.
Clin Transl Sci ; 11(6): 573-581, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30052317

RESUMO

A clinical pharmacokinetic study was performed in 12 healthy women to evaluate systemic exposure to aluminum following topical application of a representative antiperspirant formulation under real-life use conditions. A simple roll-on formulation containing an extremely rare isotope of aluminum (26 Al) chlorohydrate (ACH) was prepared to commercial specifications. A 26 Al radio-microtracer was used to distinguish dosed aluminum from natural background, using accelerated mass spectroscopy. The 26 Al citrate was administered intravenously (i.v.) to estimate fraction absorbed (Fabs ) following topical delivery. In blood samples after i.v. administration, 26 Al was readily detected (mean area under the curve (AUC) = 1,273 ± 466 hours×fg/mL). Conversely, all blood samples following topical application were below the lower limit of quantitation (LLOQ; 0.12 fg/mL), except two samples (0.13 and 0.14 fg/mL); a maximal AUC was based on LLOQs. The aluminum was above the LLOQ (61 ag/mL) in 31% of urine samples. From the urinary excretion data, a conservative estimated range for dermal Fabs of 0.002-0.06% was calculated, with a mean estimate of 0.0094%.


Assuntos
Alumínio/farmacocinética , Antiperspirantes/efeitos adversos , Radioisótopos/farmacocinética , Absorção Cutânea , Administração Cutânea , Administração Intravenosa , Adulto , Alumínio/administração & dosagem , Alumínio/efeitos adversos , Antiperspirantes/química , Área Sob a Curva , Qualidade de Produtos para o Consumidor , Feminino , Voluntários Saudáveis , Humanos , Parestesia/induzido quimicamente , Parestesia/epidemiologia , Prurido/induzido quimicamente , Prurido/epidemiologia , Radioisótopos/administração & dosagem , Radioisótopos/efeitos adversos , Eliminação Renal , Adulto Jovem
6.
Eur J Pharm Sci ; 84: 9-17, 2016 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-26747019

RESUMO

Exposure-response analyses of sugammadex on activated partial thromboplastin time (APTT) and prothrombin time international normalized ratio (PT(INR)) were performed using data from two clinical trials in which subjects were co-treated with anti-coagulants, providing a framework to predict these responses in surgical patients on thromboprophylactic doses of low molecular weight or unfractionated heparin. Sugammadex-mediated increases in APTT and PT(INR) were described with a direct effect model, and this relationship was similar in the presence or absence of anti-coagulant therapy in either healthy volunteers or surgical patients. In surgical patients on thromboprophylactic therapy, model-based predictions showed 13.1% and 22.3% increases in respectively APTT and PT(INR) within 30min after administration of 16mg/kg sugammadex. These increases remain below thresholds seen following treatment with standard anti-coagulant therapy and were predicted to be short-lived paralleling the rapid decline in sugammadex plasma concentrations.


Assuntos
Anticoagulantes/farmacologia , Coagulação Sanguínea/efeitos dos fármacos , Heparina/farmacologia , Modelos Biológicos , gama-Ciclodextrinas/farmacologia , gama-Ciclodextrinas/farmacocinética , Adolescente , Adulto , Idoso , Anticoagulantes/uso terapêutico , Estudos Cross-Over , Método Duplo-Cego , Interações Medicamentosas , Feminino , Heparina/uso terapêutico , Humanos , Masculino , Pessoa de Meia-Idade , Tempo de Tromboplastina Parcial , Tempo de Protrombina , Sugammadex , Trombose/prevenção & controle , Adulto Jovem , gama-Ciclodextrinas/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA