Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(9)2023 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-37177650

RESUMO

Three-dimensional force plates are important tools for biomechanics discovery and sports performance practice. However, currently, available 3D force plates lack portability and are often cost-prohibitive. To address this, a recently discovered 3D force sensor technology was used in the fabrication of a prototype force plate. Thirteen participants performed bodyweight and weighted lunges and squats on the prototype force plate and a standard 3D force plate positioned in series to compare forces measured by both force plates and validate the technology. For the lunges, there was excellent agreement between the experimental force plate and the standard force plate in the X-, Y-, and Z-axes (r = 0.950-0.999, p < 0.001). For the squats, there was excellent agreement between the force plates in the Z-axis (r = 0.996, p < 0.001). Across axes and movements, root mean square error (RMSE) ranged from 1.17% to 5.36% between force plates. Although the current prototype force plate is limited in sampling rate, the low RMSEs and extremely high agreement in peak forces provide confidence the novel force sensors have utility in constructing cost-effective and versatile use-case 3D force plates.


Assuntos
Fenômenos Mecânicos , Movimento , Humanos , Análise Custo-Benefício , Fenômenos Biomecânicos , Postura
2.
Sports (Basel) ; 11(4)2023 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-37104166

RESUMO

With rapid technological development over recent years, the use of wearable athlete monitoring devices has substantially gained popularity. Thus, the purpose of the present study was to examine the impact of the anatomical placement of an accelerometer on biomechanical characteristics of countermovement vertical jump with and without an arm swing when compared to the force plate as a criterion measure. Seventeen recreationally active individuals (ten males and seven females) volunteered to participate in the present study. Four identical accelerometers sampling at 100 Hz were placed at the following anatomical locations: upper-back (UB), chest (CH), abdomen (AB), and hip (HP). While standing on a uni-axial force plate system sampling at 1000 Hz, each participant completed three non-sequential maximal countermovement vertical jumps with and without an arm swing. All devices recorded the data simultaneously. The following variables of interest were obtained from ground reaction force curves: peak concentric force (PCF), peak landing force (PLF), and vertical jump height (VJH). The findings of the present study reveal that the most appropriate anatomical locations to place the accelerometer device when attempting to estimate PCF, PLF, and VJH during a countermovement vertical jump with no arm swing are CH, AB, and UB, and during a countermovement vertical jump with an arm swing are UB, HP, and UB, respectively. Overall, these findings may help strength and conditioning professionals and sports scientists to select appropriate anatomical locations when using innovative accelerometer technology to monitor vertical jump performance characteristics.

3.
Life (Basel) ; 13(1)2023 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-36676138

RESUMO

The purpose of the present study was (i) to explore the reliability of the most commonly used countermovement jump (CMJ) metrics, and (ii) to reduce a large pool of metrics with acceptable levels of reliability via principal component analysis to the significant factors capable of providing distinctive aspects of CMJ performance. Seventy-nine physically active participants (thirty-seven females and forty-two males) performed three maximal CMJs while standing on a force platform. Each participant visited the laboratory on two occasions, separated by 24-48 h. The most reliable variables were performance variables (CV = 4.2-11.1%), followed by kinetic variables (CV = 1.6-93.4%), and finally kinematic variables (CV = 1.9-37.4%). From the 45 CMJ computed metrics, only 24 demonstrated acceptable levels of reliability (CV ≤ 10%). These variables were included in the principal component analysis and loaded a total of four factors, explaining 91% of the CMJ variance: performance component (variables responsible for overall jump performance), eccentric component (variables related to the breaking phase), concentric component (variables related to the upward phase), and jump strategy component (variables influencing the jumping style). Overall, the findings revealed important implications for sports scientists and practitioners regarding the CMJ-derived metrics that should be considered to gain a comprehensive insight into the biomechanical parameters related to CMJ performance.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA