Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur Heart J Suppl ; 26(Suppl 1): i23-i28, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38867874

RESUMO

The identification of ventricular premature complexes during a cardiological evaluation necessitates the implementation of diagnostic processes aimed at discerning the clinical context that may predispose individuals to a high risk of sudden cardiac death. Epidemiological studies reveal that ventricular premature beats occur in approximately 75% of healthy (or seemingly healthy) individuals, as long as there is no evidence of underlying structural heart disease, such as benign idiopathic ventricular extrasystole originating from the right and left ventricular outflow tracts. In the real world, however, ventricular ectopic beats with morphologies very similar to seemingly benign occurrences are not uncommon. They are notable in subjects exhibiting rapid and complex repetitive forms during exercise testing and Holter electrocardiogram. Additionally, these subjects may display more or less extensive scarring signs on cardiac magnetic resonance and may have a family history of cardiomyopathy and/or sudden cardiac death. Therefore, the purpose of this review is to critically analyse the process of evaluating premature ventricular complexes, which is crucial for accurate risk stratification. The latter cannot overlook some inevitable elements, including morphology, origin, complexity, and the associated clinical setting (absence or presence of structural heart disease).

2.
medRxiv ; 2023 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-38106113

RESUMO

Background: Studies have reported that female sex predicts superior cardiac resynchronization therapy (CRT) response. One theory is that this association is related to smaller female heart size, thus increased "relative dyssynchrony" at given QRS durations (QRSd). Objective: To investigate the mechanisms of sex-specific CRT response relating to heart size, relative dyssynchrony, cardiomyopathy type, QRS morphology, and other patient characteristics. Methods: A post-hoc analysis of the MORE-CRT MPP trial (n=3739, 28% female), with a sub-group analysis of patients with non-ischaemic cardiomyopathy (NICM) and left bundle branch block (LBBB) (n=1308, 41% female) to control for confounding characteristics. A multivariable analysis examined predictors of response to 6 months of conventional CRT, including sex and relative dyssynchrony, measured by QRSd/LVEDV (left ventricular end-diastolic volume). Results: Females had a higher CRT response rate than males (70.1% vs. 56.8%, p<0.0001). Subgroup analysis: Regression analysis of the NICM LBBB subgroup identified QRSd/LVEDV, but not sex, as a modifier of CRT response (p<0.0039). QRSd/LVEDV was significantly higher in females (0.919) versus males (0.708, p<0.001). CRT response was 78% for female patients with QRSd/LVEDV>median value, compared to 68% < median value (p=0.012). Association between CRT response and QRSd/LVEDV was strongest at QRSd<150ms. Conclusions: In the NICM LBBB population, increased relative dyssynchrony in females, who have smaller heart sizes than their male counterparts, is a driver of sex-specific CRT response, particularly at QRSd <150ms. Females may benefit from CRT at a QRSd <130ms, opening the debate on whether sex-specific QRSd cut-offs or QRS/LVEDV measurement should be incorporated into clinical guidelines.

3.
Eur Heart J Suppl ; 25(Suppl C): C331-C336, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37125308

RESUMO

Heart failure (HF) is a major and still growing medical problem and is characterized by episodes of acute decompensation that are associated with a negative prognosis and a significant burden on the patients, doctors, and healthcare resources. Early detection of incipient HF may allow outpatient treatment before patients severely decompensate, thus reducing HF hospitalizations and related costs. The HeartLogic™ algorithm is an automatic, remotely managed system combining data directly related to HF pathophysiology into a single score, the HeartLogic™ index. This index proved to be effective in predicting the risk of incipient HF decompensation, allowing to redistribute resources from low-risk to high-risk patients in a timely and cost-saving manner. The alert-based remote management system seems more efficient than the one based on scheduled remote transmission in terms of caregivers' workload and alert detection timing. The widespread application of the HeartLogic™ algorithm requires the resolution of logistical and financial issues and the adoption of a pre-defined, functional workflow. In this paper, we reviewed general aspects of remote monitoring in HF patients, the functioning and pathophysiological basis of the HeartLogic index, its efficiency in the management of HF patients, and the economic effects and the organizational revolution associated with its use.

4.
Int J Cardiol Heart Vasc ; 29: 100573, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32685659

RESUMO

We designed a placebo controlled, double-blind, randomized, dose-finding phase II study on OMT-28 in the maintenance of sinus rhythm after electrical cardioversion (DCC) in patients with persistent atrial fibrillation (PROMISE-AF). OMT-28 is a first-in-class, synthetic analog of 17,18-epoxyeicosatetetraenoic acid, a bioactive lipid mediator generated by cytochrome P450 enzymes from the omega-3 fatty acid eicosapentaenoic acid. OMT-28 improves Ca2+-handling and mitochondrial function in cardiomyocytes and reduces pro-inflammatory signaling. This unique mode of action may provide a novel approach to target key mechanism contributing to AF pathophysiology. In a recent phase I study, OMT-28 was safe and well tolerated and showed favorable pharmacokinetics. The PROMISE-AF study (NCT03906799) is designed to assess the efficacy (primary objective), safety, and population pharmacokinetics (secondary objectives) of three different doses of OMT-28, administered once daily, versus placebo until the end of the follow-up period. Recruitment started in March 2019 and the study will include a total of 120 patients. The primary efficacy endpoint is the AF burden (% time with any AF), evaluated over a 13-week treatment period after DCC. AF burden is calculated based on continuous ECG monitoring using an insertable cardiac monitor (ICM). The primary efficacy analysis will be conducted on the modified intention-to-treat (mITT) population, whereas the safety analysis will be done on the safety population. Although ICMs have been used in other interventional studies to assess arrhythmia, PROMISE-AF will be the first study to assess antiarrhythmic efficacy and safety of a novel rhythm-stabilizing drug after DCC by using ICMs.

5.
J Cardiovasc Electrophysiol ; 31(5): 1166-1174, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32141116

RESUMO

INTRODUCTION: Early evidence suggests that multipoint left ventricular pacing (MPP) may improve response to cardiac resynchronization therapy (CRT). It is unknown whether this benefit is sustained and cost-effective. We used real-world data to evaluate long-term impact of MPP-ON clinical status, heart failure hospitalizations (HFH) and costs. METHODS: The Italian registry on multipoint left ventricular pacing is a prospective, multicenter registry of patients implanted with MPP-enabled CRT devices. For this analysis, clinical and echocardiographic data were collected through 24 months and compared between patients with (MPP-ON) or without (MPP-OFF) early MPP activation at implant. The total cost of each HFH was estimated with national Italian reimbursement rates. RESULTS: The study included 190 MPP-OFF and 128 MPP-ON patients with similar baseline characteristics. At 1 and 2 years, the MPP-ON group had lower rates of HFH vs MPP-OFF (1-year hazard ratio [HR]: 0.14, P = .0014; 2-year HR: 0.38, P = .009). The finding persisted in a subgroup of patients with consistent MPP activation through follow-up (1-year HR: 0.19; P = .0061; 2-year HR: 0.39, P = .022). Total HFH per-patient costs were lower in the MPP-ON vs the MPP-OFF group at 1 year (€101 ± 50 vs €698 ± 195, P < .001) and 2 years (€366 ± 149 vs €801 ± 203, P = .038). More MPP-ON patients had ≥5% improvement in ejection fraction (76.8% vs 65.4%, P = .025) and clinical composite score (66.7% vs 47.5%, P = .01). CONCLUSIONS: In this multicenter clinical study, early MPP activation was associated with a significant reduction in cumulative HFH and related costs after 1 and 2 years of follow-up.


Assuntos
Terapia de Ressincronização Cardíaca/economia , Custos de Cuidados de Saúde , Insuficiência Cardíaca/economia , Insuficiência Cardíaca/terapia , Idoso , Idoso de 80 Anos ou mais , Terapia de Ressincronização Cardíaca/efeitos adversos , Redução de Custos , Análise Custo-Benefício , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Custos Hospitalares , Hospitalização/economia , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recuperação de Função Fisiológica , Sistema de Registros , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
6.
J Cardiovasc Electrophysiol ; 25(11): 1216-23, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24964380

RESUMO

BACKGROUND: This study aimed to assess manpower and resource consumption of the HomeGuide workflow model for remote monitoring (Biotronik Home Monitoring [HM], Biotronik SE & Co. KG, Berlin, Germany) of cardiac implantable electronic devices in daily clinical practice. METHODS: The model established a cooperative interaction between a reference nurse (RN) for ordinary management, and a responsible physician (RP) for medical decisions in each outpatient clinic. RN reviewed remote transmissions and alerts, addressing critical cases to the RP. RESULTS: A total of 1,650 patients were enrolled in 75 sites: 25% pacemakers (PM), 22% dual-, 27% single-chamber implantable defibrillators (ICD), 2% PM with cardiac resynchronization therapy (CRT), and 24% ICD-CRT. During a median follow-up of 18 (10-31) months, 3,364 HM sessions were performed (74% by the RN, 26% by the RP) to complete 18,478 remote follow-ups. Median duration of remote follow-ups was 1.2 (0.6-2.0) minutes, corresponding to a manpower of 43.3 (4.2-94.8) minutes/month every 100 patients for nurses and 10.2 (0.1-31.1) for physicians (P < 0.0001). RN submitted 15% of remote transmissions to RP, who decided unscheduled follow-ups in 12% of the cases. The median manpower for phone calls was 1.9 (0.8-16.5) minutes/month every 100 contacted patients. There were 2.84 in-hospital visits/patient, 0.46 of which triggered by HM findings. A cumulative per-patient HM follow-up time of 15.4 minutes (20% of total follow-up time) allowed remote detection of 73% of actionable events. CONCLUSIONS: HM implemented in the HomeGuide workflow model required <1 hour/month every 100 patients to detect the majority of actionable events with limited administrative workload.


Assuntos
Bases de Dados Factuais , Desfibriladores Implantáveis , Mão de Obra em Saúde , Monitorização Ambulatorial/métodos , Sistema de Registros , Carga de Trabalho , Idoso , Idoso de 80 Anos ou mais , Instituições de Assistência Ambulatorial/tendências , Bases de Dados Factuais/tendências , Desfibriladores Implantáveis/tendências , Feminino , Seguimentos , Mão de Obra em Saúde/tendências , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Ambulatorial/instrumentação , Monitorização Ambulatorial/tendências , Tecnologia de Sensoriamento Remoto/instrumentação , Tecnologia de Sensoriamento Remoto/métodos , Tecnologia de Sensoriamento Remoto/tendências
7.
J Interv Card Electrophysiol ; 37(1): 69-78, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23515883

RESUMO

INTRODUCTION: Few data are available on actual follow-up costs of remote monitoring (RM) of implantable defibrillators (ICD). Our study aimed at assessing current direct costs of 1-year ICD follow-up based on RM compared with conventional quarterly in-hospital follow-ups. METHODS AND RESULTS: Patients (N = 233) with indications for ICD were consecutively recruited and randomized at implant to be followed up for 1 year with standard quarterly in-hospital visits or by RM with one in-hospital visit at 12 months, unless additional in-hospital visits were required due to specific patient conditions or RM alarms. Costs were calculated distinguishing between provider and patient costs, excluding RM device and service cost. The frequency of scheduled in-hospital visits was lower in the RM group than in the control arm. Follow-up required 47 min per patient/year in the RM arm versus 86 min in the control arm (p = 0.03) for involved physicians, generating cost estimates for the provider of USD 45 and USD 83 per patient/year, respectively. Costs for nurses were comparable. Overall, the costs associated with RM and standard follow-up were USD 103 ± 27 and 154 ± 21 per patient/year, respectively (p = 0.01). RM was cost-saving for the patients: USD 97 ± 121 per patient/year in the RM group versus 287 ± 160 per patient/year (p = 0.0001). CONCLUSION: The time spent by the hospital staff was significantly reduced in the RM group. If the costs for the device and service are not charged to patients or the provider, patients could save about USD 190 per patient/year while the hospital could save USD 51 per patient/year.


Assuntos
Desfibriladores Implantáveis/economia , Análise de Falha de Equipamento/economia , Custos de Cuidados de Saúde/estatística & dados numéricos , Insuficiência Cardíaca/economia , Insuficiência Cardíaca/prevenção & controle , Hospitalização/economia , Telemedicina/economia , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise Custo-Benefício/métodos , Feminino , Seguimentos , Gastos em Saúde/estatística & dados numéricos , Insuficiência Cardíaca/epidemiologia , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Prevalência
8.
J Cardiovasc Med (Hagerstown) ; 9(12): 1280-1, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19001940

RESUMO

The present case report is of a 36-year-old man who had been symptomatic for frequent palpitations for 4 years after a prolonged febrile episode. The electrocardiogram on admission revealed an iterative supraventricular tachycardia at rate of 110 bpm, with ventriculoatrial interval of 180 ms and superior P-wave axis. Electroanatomic mapping showed substantially normal values in the right atrium other than an area along the posteroseptal region of the tricuspid annulus, with a low-voltage region that correlated with the area of earliest activation.


Assuntos
Mapeamento Potencial de Superfície Corporal , Taquicardia Atrial Ectópica/etiologia , Adulto , Eletrocardiografia , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA