Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Cancers (Basel) ; 15(4)2023 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-36831368

RESUMO

Early assessment of neoadjuvant systemic therapy (NAST) response for triple-negative breast cancer (TNBC) is critical for patient care in order to avoid the unnecessary toxicity of an ineffective treatment. We assessed functional tumor volumes (FTVs) from dynamic contrast-enhanced (DCE) MRI after 2 cycles (C2) and 4 cycles (C4) of NAST as predictors of response in TNBC. A group of 100 patients with stage I-III TNBC who underwent DCE MRI at baseline, C2, and C4 were included in this study. Tumors were segmented on DCE images of 1 min and 2.5 min post-injection. FTVs were measured using the optimized percentage enhancement (PE) and signal enhancement ratio (SER) thresholds. The Mann-Whitney test was used to compare the performance of the FTVs at C2 and C4. Of the 100 patients, 49 (49%) had a pathologic complete response (pCR) and 51 (51%) had a non-pCR. The maximum area under the receiving operating characteristic curve (AUC) for predicting the treatment response was 0.84 (p < 0.001) for FTV at C4 followed by FTV at C2 (AUC = 0.82, p < 0.001). The FTV measured at baseline was not able to discriminate pCR from non-pCR. FTVs measured on DCE MRI at C2, as well as at C4, of NAST can potentially predict pCR and non-pCR in TNBC patients.

2.
Ann Surg Oncol ; 25(7): 1953-1960, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29667115

RESUMO

PURPOSE: This study was designed to present the secondary imaging endpoints of the trial for evaluating mammogram (MMG), ultrasound (US) and image guided biopsy (IGBx) assessment of pathologic complete response (pCR) in breast cancer (BC) patients undergoing neoadjuvant chemotherapy (NAC). METHODS: Patients with T1-3, N0-3, M0 triple-negative or HER2-positive BC who received NAC were enrolled in an Institutional Review Board-approved prospective, clinical trial. Patients underwent US and MMG at baseline and after NAC. Images were evaluated for residual abnormality and to determine modality for IGBx [US-guided (USG) or stereotactic guided (SG)]. Fine-needle aspiration and 9-G, vacuum-assisted core biopsy (VACBx) of tumor bed was performed after NAC and was compared with histopathology at surgery. RESULTS: Forty patients were enrolled. Median age was 50.5 (range 26-76) years; median baseline tumor size was 2.4 cm (range 0.8-6.3) and 1 cm (range 0-5.5) after NAC. Nineteen patients had pCR: 6 (32%) had residual Ca2+ presurgery, 5 (26%) residual mass, 1 (5%) mass with calcifications, and 7 (37%) no residual imaging abnormality. Sensitivity, specificity, and accuracy of US, MMG, and IGBx for pCR were 47/95/73%, 53/90/73%, and 100/95/98%, respectively. Twenty-five (63%) patients had SGBx and 15 (37%) had US-guided biopsy (USGBx). Median number of cores was higher with SGBx (12, range 6-14) than with USGBx (8, range 4-12), p < 0.002. Positive predictive value for pCR was significantly higher for SG VACBx than for USG VACBx (100 vs. 60%, p < 0.05). CONCLUSIONS: SG VACBx is the preferred IGBx modality for identifying patients with pCR for trials testing the safety of eliminating surgery.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Biópsia Guiada por Imagem/métodos , Mamografia/métodos , Terapia Neoadjuvante , Ultrassonografia Mamária/métodos , Adulto , Idoso , Biópsia por Agulha Fina , Neoplasias da Mama/tratamento farmacológico , Quimioterapia Adjuvante , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos
3.
Br J Radiol ; 89(1065): 20160401, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27384241

RESUMO

OBJECTIVE: To compare the incremental cancer detection rate (ICDR) using bilateral whole-breast ultrasonography (BWBUS) vs dynamic contrast-enhanced MRI in patients with primary breast cancer. METHODS: A retrospective database search in a single institution identified 259 patients with breast cancer diagnosed from January 2011 to August 2014 who underwent mammography, BWBUS and MRI before surgery. Patient characteristics, tumour characteristics and lesions seen on each imaging modality were recorded. The sensitivity, specificity and accuracy for each modality were calculated. ICDRs according to index tumour histology and receptor status were also evaluated. The effect of additional cancer detection on surgical planning was obtained from the medical records. RESULTS: A total of 266 additional lesions beyond 273 index malignancies were seen on at least 1 modality, of which 121 (45%) lesions were malignant and 145 (55%) lesions were benign. MRI was significantly more sensitive than BWBUS (p = 0.01), while BWBUS was significantly more accurate and specific than MRI (p < 0.0001). Compared with mammography, the ICDRs using BWBUS and MRI were significantly higher for oestrogen receptor-positive and triple-negative cancers, but not for human epidermal growth factor receptor 2-positive cancers. 22 additional malignant lesions in 18 patients were seen on MRI only. Surgical planning remained unchanged in 8 (44%) of those 18 patients. CONCLUSION: MRI was more sensitive than BWBUS, while BWBUS was more accurate and specific than MRI. MRI-detected additional malignant lesions did not change surgical planning in almost half of these patients. ADVANCES IN KNOWLEDGE: BWBUS may be a cost-effective and practical tool in breast cancer staging.


Assuntos
Neoplasias da Mama/diagnóstico , Biópsia por Agulha/economia , Biópsia por Agulha/normas , Neoplasias da Mama/economia , Análise Custo-Benefício , Detecção Precoce de Câncer , Feminino , Humanos , Biópsia Guiada por Imagem/economia , Biópsia Guiada por Imagem/normas , Imageamento por Ressonância Magnética/economia , Imageamento por Ressonância Magnética/normas , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Cuidados Pré-Operatórios , Estudos Retrospectivos , Sensibilidade e Especificidade , Ultrassonografia Mamária/economia , Ultrassonografia Mamária/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA