Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Radiol Med ; 127(11): 1254-1269, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36114929

RESUMO

PURPOSE: Our purpose is to assess Multiparametric Ultrasound (MPUS) efficacy for evaluation of carotid plaque vulnerability and carotid stenosis degree in comparison with Computed Tomography angiography (CTA) and histology. MATERIAL AND METHODS: 3D-Arterial Analysis is a 3D ultrasound software that automatically provides the degree of carotid stenosis and a colorimetric map of carotid plaque vulnerability. We enrolled 106 patients who were candidates for carotid endarterectomy. Prior to undergoing surgery, all carotid artery plaques were evaluated with Color-Doppler-US (CDUS), Contrast-Enhanced Ultrasound (CEUS), and 3D Arterial analysis (3DAA) US along with Computerized Tomographic Angiography (CTA) to assess the carotid artery stenosis degree. Post-surgery, the carotid specimens were fixed with 10% neutral buffered formalin solution, embedded in paraffin and used for light microscopic examination to assess plaque vulnerability morphological features. RESULTS: The results of the CTA examinations revealed 91 patients with severe carotid stenoses with a resultant diagnostic accuracy of 82.3% for CDUS, 94.5% for CEUS, 98.4% for 3DAA, respectively. The histopathological examination showed 71 vulnerable plaques with diagnostic accuracy values of 85.8% for CDUS, 93.4% for CEUS, 90.3% for 3DAA, 92% for CTA, respectively. CONCLUSIONS: The combination of CEUS and 3D Arterial Analysis may provide a powerful new clinical tool to identify and stratify "at-risk" patients with atherosclerotic carotid artery disease, identifying vulnerable plaques. These applications may also help in the postoperative assessment of treatment options to manage cardiovascular risks.


Assuntos
Estenose das Carótidas , Placa Aterosclerótica , Humanos , Placa Aterosclerótica/diagnóstico por imagem , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/cirurgia , Angiografia por Tomografia Computadorizada , Parafina , Meios de Contraste , Ultrassonografia Doppler em Cores/métodos , Artérias Carótidas/diagnóstico por imagem , Ultrassonografia/métodos , Angiografia , Software , Formaldeído
2.
Radiol Med ; 126(9): 1236-1248, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34160775

RESUMO

In the past 20 years, Cardiac Computed Tomography (CCT) has become a pivotal technique for the noninvasive diagnostic work-up of coronary and cardiac diseases. Continuous technical and methodological improvements, combined with fast growing scientific evidence, have progressively expanded the clinical role of CCT. Recent large multicenter randomized clinical trials documented the high prognostic value of CCT and its capability to increase the cost-effectiveness of the management of patients with suspected CAD. In the meantime, CCT, initially perceived as a simple non-invasive technique for studying coronary anatomy, has transformed into a multiparametric "one-stop-shop" approach able to investigate the heart in a comprehensive way, including functional, structural and pathophysiological biomarkers. In this complex and revolutionary scenario, it is urgently needed to provide an updated guide for the appropriate use of CCT in different clinical settings. This manuscript, endorsed by the Italian Society of Medical and Interventional Radiology (SIRM) and by the Italian Society of Cardiology (SIC), represents the first of two consensus documents collecting the expert opinion of Radiologists and Cardiologists about current appropriate use of CCT.


Assuntos
Técnicas de Imagem Cardíaca , Angiografia por Tomografia Computadorizada , Doença das Coronárias/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico por imagem , Coração/diagnóstico por imagem , Cuidados Pré-Operatórios , Calcinose/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico , Humanos , Prevenção Primária
3.
Clin Rheumatol ; 39(5): 1537-1542, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31940114

RESUMO

Interstitial lung disease (ILD) remains a major cause of morbidity and mortality in systemic sclerosis (SSc). Study aim is to characterize and quantify SSc-ILD by using Computer-Aided Lung Informatics for Pathology Evaluation and Rating (CALIPER). Secondly, our objective is to evaluate which radiological pattern is predictive of lung function decline at 12 months follow-up. In the prospective study (IRB 5435), 66 SSc patients underwent high-resolution computerized tomography (HRCT) at baseline. HRCT was performed according to standard protocol using a CT 64GE light speed VCT power scanner. CALIPER classified lung parenchyma on volume units. Every volume unit was classified into radiological parenchymal patterns (honeycombing, reticular and ground glass). Pulmonary function tests (PFTs) were performed at baseline and after 12 months of follow-up. Cigarette smoking and other lung diseases unrelated to SSc are exclusion criteria. CALIPER analysis showed normal lung parenchyma 87.4 ± 9.8%, ground glass 2.8 ± 5.3%, reticular 4 ± 5.7%, and honeycombing 1 ± 1%. In multiple regression analysis, FEV1 (p < 0.0001), FVC (p = 0.001), and DLCO (p < 0.0001) measurements at baseline showed a negative correlation with the reticular pattern percentage. At follow-up, DLCO reduction showed a positive correlation (p < 0.001) with the percentage of ground glass pattern (r = 0.33, beta coefficient = 0.51). In the ROC curve analysis, ground glass score is a good predictor (0.75, p = 0.009; 95% CI 0.59-0.91) of DLCO worsening, defined as a decrease of more than 10% of DLCO. Using a cutoff ≥ 4.5 for ground glass score, the RR for DLCO worsening is 6.8 (p < 0.01; 95% CI 1.6-29.2). The results of this study show that CALIPER is useful not only for quantifying lung damage but also for assessing worsening PFTs, but larger studies are needed to confirm these preliminary data.Key Points• At baseline reticular pattern showed negative correlation with PFTs• At follow-up ground glass pattern predicts worsening of DLCO• CALIPER is a useful to quantify lung damage.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Doenças Pulmonares Intersticiais/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Escleroderma Sistêmico/complicações , Software , Adulto , Idoso , Algoritmos , Feminino , Humanos , Pulmão/fisiopatologia , Doenças Pulmonares Intersticiais/etiologia , Doenças Pulmonares Intersticiais/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Análise de Regressão , Testes de Função Respiratória , Tomografia Computadorizada por Raios X/métodos
4.
AJR Am J Roentgenol ; 212(5): 1044-1053, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30835518

RESUMO

OBJECTIVE. The objective of our study was to perform a systematic review and meta-analysis to evaluate the diagnostic accuracy of dual-energy CT (DECT) for renal mass evaluation. MATERIALS AND METHODS. In March 2018, we searched MEDLINE, Cochrane Database of Systematic Reviews, Embase, and Web of Science databases. Analytic methods were based on Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). Pooled estimates for sensitivity, specificity, and diagnostic odds ratios were calculated for DECT-based virtual monochromatic imaging (VMI) and iodine quantification techniques as well as for conventional attenuation measurements from renal mass CT protocols. I2 was used to evaluate heterogeneity. The methodologic quality of the included studies and potential bias were assessed using items from the Quality Assessment Tool for Diagnostic Accuracy Studies 2 (QUADAS-2). RESULTS. Of the 1043 articles initially identified, 13 were selected for inclusion (969 patients, 1193 renal masses). Cumulative data of sensitivity, specificity, and summary diagnostic odds ratio for VMI were 87% (95% CI, 80-92%; I2, 92.0%), 93% (95% CI, 90-96%; I2, 18.0%), and 183.4 (95% CI, 30.7-1093.4; I2, 61.6%), respectively. Cumulative data of sensitivity, specificity, and summary diagnostic odds ratio for iodine quantification were 99% (95% CI, 97-100%; I2, 17.6%), 91% (95% CI, 89-94%; I2, 84.2%), and 511.5 (95% CI, 217-1201; I2, 0%). No significant differences in AUCs were found when comparing iodine quantification to conventional attenuation measurements (p = 0.79). CONCLUSION. DECT yields high accuracy for renal mass evaluation. Determination of iodine content with the iodine quantification technique shows diagnostic accuracy similar to conventional attenuation measurements from renal mass CT protocols. The iodine quantification technique may be used to characterize incidental renal masses when a dedicated renal mass protocol is not available.

5.
Eur Heart J Cardiovasc Imaging ; 14(11): 1041-8, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23793878

RESUMO

AIMS: Previous studies have shown that prodromal angina (PA) occurs frequently in acute myocardial infarction (MI) patients. However, the potential benefits of PA on ischaemic myocardial damage remain unknown. METHODS AND RESULTS: One-hundred and fifty-four patients with acute ST-segment elevation MI successfully treated with primary percutaneous coronary intervention (PPCI) were prospectively evaluated for new-onset PA in the week preceding infarction and other factors known to influence myocardial salvage. Cardiovascular magnetic resonance was performed 8 ± 3 days after MI for the assessment of area-at-risk (AAR), MI size, myocardial haemorrhage (MH), microvascular obstruction (MO), and myocardial salvage index (MSI). Patients with PA (n = 60) compared with those without PA (n = 94) showed similar AAR but significantly smaller MI size leading to larger MSI (0.53 ± 0.27 vs. 0.32 ± 0.26, P < 0.001). Additionally, patients with PA had lower incidence of MH (18 vs. 33%) and MO (22 vs. 46%) than non-PA patients (both P < 0.05). At univariate analysis, higher MSI was associated with new-onset PA, lower myocardial oxygen consumption before PPCI, shorter time-to-PPCI, and higher post-procedural TIMI flow-grade. Neither collateral circulation nor medications administered before PPCI were associated to MSI. After correction for other covariates by multivariate analysis, new-onset PA remained significantly associated with MSI (ß-value: 0.352, P < 0.001). CONCLUSION: In acute MI patients, new-onset PA is associated with higher MSI independent of others factors known to influence jeopardized myocardium, as well as with less microvascular damage.


Assuntos
Angina Pectoris/diagnóstico , Angina Pectoris/terapia , Imagem Cinética por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/terapia , Sintomas Prodrômicos , Terapia de Salvação , Idoso , Análise de Variância , Angina Pectoris/mortalidade , Angioplastia Coronária com Balão/métodos , Estudos de Coortes , Comorbidade , Angiografia Coronária/métodos , Circulação Coronária/fisiologia , Eletrocardiografia/métodos , Feminino , Seguimentos , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Infarto do Miocárdio/mortalidade , Estudos Prospectivos , Medição de Risco , Índice de Gravidade de Doença , Estatísticas não Paramétricas , Taxa de Sobrevida , Fatores de Tempo , Resultado do Tratamento
7.
J Comput Assist Tomogr ; 32(5): 668-78, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18830094

RESUMO

OBJECTIVE: To evaluate dose reduction and image quality in coronary 64-slice multidetector computed tomography using an automatic exposure control system (AECs). METHODS: A total of 101 patients were divided into 4 groups. Tube current was 600 and 800 mAs in groups A and B and adapted at 600 and 800 quality-reference mAs using an AECs in groups C and D. Effective dose and organ-equivalent dose were evaluated. Image noise was quantified as standard deviation of air-space attenuation. Two observers assessed technical adequacy and image quality using a 4-point scale. RESULTS: Effective dose ranged from 8.6 mSv (group C) to 15 mSv (group B) with significant dose reduction for examinations performed at 600 mAs (21.7%) and 800 mAs (29.4%). Contribution of organ-equivalent doses showed higher exposure for lungs (42%) and breast (22%). Noise was significantly higher in groups studied with AECs. Larger coronary segments resulted in higher image quality scores without differences between groups. CONCLUSION: Automatic exposure control systems provides images of diagnostic quality with substantial dose reduction.


Assuntos
Angiografia Coronária/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia Coronária/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos
8.
Eur Radiol ; 16(1): 15-24, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16402255

RESUMO

Our objective was to retrospectively evaluate the ability of multidetector-row computed tomography (MDCT) to detect previous myocardial infarctions (MIs) and to correlate necrosis with the status of coronary arteries supplying the infarcted territory. After having clinically evaluated 187 patients referred for ECG-gated MDCT of the coronary arteries, 30 previous MIs were identified in 29 patients (9 recent and 21 chronic). MDCT data were evaluated qualitatively and quantitatively by measuring attenuation values and wall thickness within the infarcted region and normal adjacent myocardium. Each MI was also assigned to the distribution territory of a coronary vessel, and morphological data were combined with MDCT angiographic findings. MDCT was able to detect 25/30 MIs showing an overall sensitivity and specificity of 83 and 91%, respectively. Quantitative analysis revealed a statistically significant difference in attenuation values between normal and infarcted regions (38.9+/-14 HU vs. 104.0+/-16 HU). Regional wall thinning was observed in chronic MIs (4.1+/-2 mm vs. 10.5+/-3.8 mm), and not in patients with recent event (7.9+/-1.6 mm vs 9.1+/-4 mm). In 22/25 cases, MDCT angiographic findings showed the presence of suspicious critical lumen narrowing (n=3), previous coronary stenting (n=14) and surgical revascularization (n=5) in the infarct-related coronary. During a single examination, MDCT might provide comprehensive imaging of MI offering a combined morphological and angiographic assessment.


Assuntos
Angiografia Coronária/métodos , Eletrocardiografia/métodos , Infarto do Miocárdio/diagnóstico , Tomografia Computadorizada Espiral/métodos , Adulto , Idoso , Algoritmos , Humanos , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Necrose/etiologia , Variações Dependentes do Observador , Estudos Retrospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA