Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Neurophotonics ; 11(1): 015004, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38282721

RESUMO

Significance: The non-invasive measurement of cerebral blood flow based on diffuse optical techniques has seen increased interest as a research tool for cerebral perfusion monitoring in critical care and functional brain imaging. Diffuse correlation spectroscopy (DCS) and speckle contrast optical spectroscopy (SCOS) are two such techniques that measure complementary aspects of the fluctuating intensity signal, with DCS quantifying the temporal fluctuations of the signal and SCOS quantifying the spatial blurring of a speckle pattern. With the increasing interest in the use of these techniques, a thorough comparison would inform new adopters of the benefits of each technique. Aim: We systematically evaluate the performance of DCS and SCOS for the measurement of cerebral blood flow. Approach: Monte Carlo simulations of dynamic light scattering in an MRI-derived head model were performed. For both DCS and SCOS, estimates of sensitivity to cerebral blood flow changes, coefficient of variation of the measured blood flow, and the contrast-to-noise ratio of the measurement to the cerebral perfusion signal were calculated. By varying complementary aspects of data collection between the two methods, we investigated the performance benefits of different measurement strategies, including altering the number of modes per optical detector, the integration time/fitting time of the speckle measurement, and the laser source delivery strategy. Results: Through comparison across these metrics with simulated detectors having realistic noise properties, we determine several guiding principles for the optimization of these techniques and report the performance comparison between the two over a range of measurement properties and tissue geometries. We find that SCOS outperforms DCS in terms of contrast-to-noise ratio for the cerebral blood flow signal in the ideal case simulated here but note that SCOS requires careful experimental calibrations to ensure accurate measurements of cerebral blood flow. Conclusion: We provide design principles by which to evaluate the development of DCS and SCOS systems for their use in the measurement of cerebral blood flow.

2.
J Biomed Opt ; 28(10): 100501, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37811478

RESUMO

Significance: Monte Carlo (MC) simulations are currently the gold standard in the near-infrared and diffuse correlation spectroscopy (NIRS/DCS) communities for generating light transport paths through tissue. However, realistic and diverse models that capture complex tissue layers are not easily available to all; moreover, manually placing optodes on such models can be tedious and time consuming. Such limitations may hinder the adoption of representative models for basic simulations and the use of these models for large-scale simulations, e.g., for training machine learning algorithms. Aim: We aim to provide the NIRS/DCS communities with an open-source, user-friendly database of morphologically and optically realistic head models, as well as a succinct software pipeline to prepare these models for mesh-based Monte Carlo simulations of light transport. Approach: Sixteen anatomical models were created from segmented T1-weighted magnetic resonance imaging (MRI) head scans and converted to tetrahedral mesh volumes. Approximately 800 companion scalp surface locations were distributed on each model, comprising full head coverage. A pipeline was created to place custom source and optical detectors at each location, and guidance is provided on how to use these parameters to set up MC simulations. Results: The models, head surface locations, and all associated code are freely available under the scatterBrains project on Github. Conclusions: The NIRS/DCS community benefits from having shared resources for conducting MC simulations on realistic head geometries. We hope this will make MRI-based head models and virtual optode placement easily accessible to all. Contributions to the database are welcome and encouraged.


Assuntos
Simulação por Computador , Cabeça , Imagens de Fantasmas , Software , Humanos , Algoritmos , Método de Monte Carlo , Fótons
3.
Neuroimage ; 256: 119216, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35452803

RESUMO

Currently, there is great interest in making neuroimaging widely accessible and thus expanding the sampling population for better understanding and preventing diseases. The use of wearable health devices has skyrocketed in recent years, allowing continuous assessment of physiological parameters in patients and research cohorts. While most health wearables monitor the heart, lungs and skeletal muscles, devices targeting the brain are currently lacking. To promote brain health in the general population, we developed a novel, low-cost wireless cerebral oximeter called FlexNIRS. The device has 4 LEDs and 3 photodiode detectors arranged in a symmetric geometry, which allows for a self-calibrated multi-distance method to recover cerebral hemoglobin oxygenation (SO2) at a rate of 100 Hz. The device is powered by a rechargeable battery and uses Bluetooth Low Energy (BLE) for wireless communication. We developed an Android application for portable data collection and real-time analysis and display. Characterization tests in phantoms and human participants show very low noise (noise-equivalent power <70 fW/√Hz) and robustness of SO2 quantification in vivo. The estimated cost is on the order of $50/unit for 1000 units, and our goal is to share the device with the research community following an open-source model. The low cost, ease-of-use, smart-phone readiness, accurate SO2 quantification, real time data quality feedback, and long battery life make prolonged monitoring feasible in low resource settings, including typically medically underserved communities, and enable new community and telehealth applications.


Assuntos
Encéfalo/fisiologia , Oximetria/métodos , Dispositivos Eletrônicos Vestíveis , Tecnologia sem Fio , Cabeça , Hemoglobinas/análise , Humanos , Oximetria/economia , Oximetria/instrumentação , Imagens de Fantasmas , Dispositivos Eletrônicos Vestíveis/economia , Tecnologia sem Fio/economia
5.
Neurophotonics ; 8(1): 015001, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33437846

RESUMO

Significance: Contamination of diffuse correlation spectroscopy (DCS) measurements of cerebral blood flow (CBF) due to systemic physiology remains a significant challenge in the clinical translation of DCS for neuromonitoring. Tunable, multi-layer Monte Carlo-based (MC) light transport models have the potential to remove extracerebral flow cross-talk in cerebral blood flow index ( CBF i ) estimates. Aim: We explore the effectiveness of MC DCS models in recovering accurate CBF i changes in the presence of strong systemic physiology variations during a hypercapnia maneuver. Approach: Multi-layer slab and head-like realistic (curved) geometries were used to run MC simulations of photon propagation through the head. The simulation data were post-processed into models with variable extracerebral thicknesses and used to fit DCS multi-distance intensity autocorrelation measurements to estimate CBF i timecourses. The results of the MC CBF i values from a set of human subject hypercapnia sessions were compared with CBF i values estimated using a semi-infinite analytical model, as commonly used in the field. Results: Group averages indicate a gradual systemic increase in blood flow following a different temporal profile versus the expected rapid CBF response. Optimized MC models, guided by several intrinsic criteria and a pressure modulation maneuver, were able to more effectively separate CBF i changes from scalp blood flow influence than the analytical fitting, which assumed a homogeneous medium. Three-layer models performed better than two-layer ones; slab and curved models achieved largely similar results, though curved geometries were closer to physiological layer thicknesses. Conclusion: Three-layer, adjustable MC models can be useful in separating distinct changes in scalp and brain blood flow. Pressure modulation, along with reasonable estimates of physiological parameters, can help direct the choice of appropriate layer thicknesses in MC models.

6.
J Biomed Opt ; 22(12): 121604, 2017 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-29389104

RESUMO

We present a framework for characterizing the performance of an experimental imaging technology, diffuse optical spectroscopic imaging (DOSI), in a 2-year multicenter American College of Radiology Imaging Network (ACRIN) breast cancer study (ACRIN-6691). DOSI instruments combine broadband frequency-domain photon migration with time-independent near-infrared (650 to 1000 nm) spectroscopy to measure tissue absorption and reduced scattering spectra and tissue hemoglobin, water, and lipid composition. The goal of ACRIN-6691 was to test the effectiveness of optically derived imaging endpoints in predicting the final pathologic response of neoadjuvant chemotherapy (NAC). Sixty patients were enrolled over a 2-year period at participating sites and received multiple DOSI scans prior to and during 3- to 6-month NAC. The impact of three sources of error on accuracy and precision, including different operators, instruments, and calibration standards, was evaluated using a broadband reflectance standard and two different solid tissue-simulating optical phantoms. Instruments showed <0.0010 mm−1 (10.3%) and 0.06 mm−1 (4.7%) deviation in broadband absorption and reduced scattering, respectively, over the 2-year duration of ACRIN-6691. These variations establish a useful performance criterion for assessing instrument stability. The proposed procedures and tests are not limited to DOSI; rather, they are intended to provide methods to characterize performance of any instrument used in translational optical imaging.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Imagem Óptica/métodos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Neoplasias da Mama/tratamento farmacológico , Quimioterapia Adjuvante , Ensaios Clínicos como Assunto , Monitoramento de Medicamentos/instrumentação , Monitoramento de Medicamentos/métodos , Desenho de Equipamento , Feminino , Humanos , Imagem Óptica/instrumentação , Imagens de Fantasmas , Espectroscopia de Luz Próxima ao Infravermelho/instrumentação
7.
J Cereb Blood Flow Metab ; 32(3): 481-8, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22027937

RESUMO

Little is known about cerebral blood flow, cerebral blood volume (CBV), oxygenation, and oxygen consumption in the premature newborn brain. We combined quantitative frequency-domain near-infrared spectroscopy measures of cerebral hemoglobin oxygenation (SO(2)) and CBV with diffusion correlation spectroscopy measures of cerebral blood flow index (BF(ix)) to determine the relationship between these measures, gestational age at birth (GA), and chronological age. We followed 56 neonates of various GA once a week during their hospital stay. We provide absolute values of SO(2) and CBV, relative values of BF(ix), and relative cerebral metabolic rate of oxygen (rCMRO(2)) as a function of postmenstrual age (PMA) and chronological age for four GA groups. SO(2) correlates with chronological age (r=-0.54, P value ≤0.001) but not with PMA (r=-0.07), whereas BF(ix) and rCMRO(2) correlate better with PMA (r=0.37 and 0.43, respectively, P value ≤0.001). Relative CMRO2 during the first month of life is lower when GA is lower. Blood flow index and rCMRO(2) are more accurate biomarkers of the brain development than SO(2) in the premature newborns.


Assuntos
Encéfalo/metabolismo , Recém-Nascido Prematuro/crescimento & desenvolvimento , Recém-Nascido Prematuro/metabolismo , Oxigênio/metabolismo , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Encéfalo/irrigação sanguínea , Encéfalo/crescimento & desenvolvimento , Circulação Cerebrovascular , Processamento Eletrônico de Dados , Feminino , Idade Gestacional , Hemoglobinas/análise , Humanos , Lactente , Recém-Nascido , Recém-Nascido Prematuro/sangue , Modelos Lineares , Masculino , Espectroscopia de Luz Próxima ao Infravermelho/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA