1.
JAMA Cardiol ; 8(12): 1165-1173, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37851461

RESUMO

Importance: Complete hardware removal is a class I recommendation for cardiovascular implantable electronic device (CIED) infection, but practice patterns and outcomes remain unknown. Objective: To quantify the number of Medicare patients with CIED infections who underwent implantation from 2006 to 2019 and lead extraction from 2007 to 2019 to analyze the outcomes in these patients in a nationwide clinical practice cohort. Design, Setting, and Participants: This cohort study included fee-for-service Medicare Part D beneficiaries from January 1, 2006, to December 31, 2019, who had a de novo CIED implantation and a CIED infection more than 1 year after implantation. Data were analyzed from January 1, 2005, to December 31, 2019. Exposure: A CIED infection, defined as (1) endocarditis or infection of a device implant and (2) documented antibiotic therapy. Main Outcomes and Measures: The primary outcomes of interest were device infection, device extraction, and all-cause mortality. Time-varying multivariable Cox proportional hazards regression models were used to evaluate the association between extraction and survival. Results: Among 1 065 549 patients (median age, 78.0 years [IQR, 72.0-84.0 years]; 50.9% male), mean (SD) follow-up was 4.6 (2.9) years after implantation. There were 11 304 patients (1.1%) with CIED infection (median age, 75.0 years [IQR, 67.0-82.0 years]); 60.1% were male, and 7724 (68.3%) had diabetes. A total of 2102 patients with CIED infection (18.6%) underwent extraction within 30 days of diagnosis. Infection occurred a mean (SD) of 3.7 (2.4) years after implantation, and 1-year survival was 68.3%. There was evidence of highly selective treatment, as most patients did not have extraction within 30 days of diagnosed infection (9202 [81.4%]), while 1511 (13.4%) had extraction within 6 days of diagnosis and 591 (5.2%) had extraction between days 7 and 30. Any extraction was associated with lower mortality compared with no extraction (adjusted hazard ratio [AHR], 0.82; 95% CI, 0.74-0.90; P < .001). Extraction within 6 days was associated with even lower risk of mortality (AHR, 0.69; 95% CI, 0.61-0.78; P < .001). Conclusions and Relevance: In this study, a minority of patients with CIED infection underwent extraction. Extraction was associated with a lower risk of death compared with no extraction. The findings suggest a need to improve adherence to guideline-directed care among patients with CIED infection.


Assuntos
Desfibriladores Implantáveis , Endocardite , Humanos , Masculino , Idoso , Estados Unidos/epidemiologia , Feminino , Desfibriladores Implantáveis/efeitos adversos , Estudos de Coortes , Medicare , Fatores de Risco
2.
Circulation ; 136(15): 1387-1395, 2017 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-28830879

RESUMO

BACKGROUND: Lead management is an increasingly important aspect of care in patients with cardiac implantable electronic devices; however, relatively little is known about long-term outcomes after capping and abandoning leads. METHODS: Using the 5% Medicare sample, we identified patients with de novo cardiac implantable electronic device implantations between January 1, 2000, and December 31, 2013, and with a subsequent lead addition or extraction ≥12 months after the de novo implantation. Patients who underwent extraction for infection were excluded. Using multivariable Cox proportional hazards models, we compared cumulative incidence of all-cause mortality, device-related infection, device revision, and lead extraction at 1 and 5 years for the extraction versus the cap and abandon group. RESULTS: Among 6859 patients, 1113 (16.2%) underwent extraction, whereas 5746 (83.8%) underwent capping and abandonment. Extraction patients tended to be younger (median, 78 versus 79 years; P<0.0001), were less likely to be male (65% versus 68%; P=0.05), and had shorter lead dwell time (median, 3.0 versus 4.0 years; P<0.0001) and fewer comorbidities. Over a median follow-up of 2.4 years (25th, 75th percentiles, 1.0, 4.3 years), the overall 1-year and 5-year cumulative incidence of mortality was 13.5% (95% confidence interval [CI], 12.7-14.4) and 54.3% (95% CI, 52.8-55.8), respectively. Extraction was associated with a lower risk of device infection at 5 years relative to capping (adjusted hazard ratio, 0.78; 95% CI, 0.62-0.97; P=0.027). There was no association between extraction and mortality, lead revision, or lead extraction at 5 years. CONCLUSIONS: Elective lead extraction for noninfectious indications had similar long-term survival to that for capping and abandoning leads in a Medicare population. However, extraction was associated with lower risk of device infections at 5 years.


Assuntos
Estimulação Cardíaca Artificial , Desfibriladores Implantáveis , Remoção de Dispositivo/mortalidade , Marca-Passo Artificial , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Medicare , Taxa de Sobrevida , Estados Unidos
3.
Heart Rhythm ; 12(7): 1565-73, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25839113

RESUMO

BACKGROUND: Prevention of sudden cardiac arrest (SCA) after removal of an infected implantable cardioverter-defibrillator (ICD) is a challenging clinical dilemma. The cost-effectiveness of the wearable cardioverter-defibrillator (WCD) in this setting remains uncertain. OBJECTIVE: The purpose of this study was to compare the cost-effectiveness of the WCD with discharge home, discharge to a skilled nursing facility, or inpatient monitoring for the prevention of SCA after infected ICD removal. METHODS: A decision model was developed to compare the cost-effectiveness of use of the WCD to several different strategies for patients who undergo ICD removal. One-way and 2-way sensitivity analyses were performed to account for uncertainties. RESULTS: In the base-case analysis, the incremental cost-effectiveness of the WCD strategy was $20,300 per life-year (LY) or $26,436 per quality-adjusted life-year (QALY) compared to discharge home without a WCD. Discharge to a skilled nursing facility and in-hospital monitoring resulted in higher costs and worse clinical outcomes. The incremental cost-effectiveness ratio was as low as $15,392/QALY if the WCD successfully terminated 95% of SCA events and exceeded the $50,000/QALY willingness-to-pay threshold if the efficacy was <69%.The WCD strategy remained cost-effective, assuming 5.6% 2-month SCA risk, as long as the time to reimplantation was at least 2 weeks. CONCLUSION: The WCD likely is cost-effective in protecting patients against SCA after infected ICD removal while waiting for ICD reimplantation compared to keeping patients in the hospital or discharging them home or to a skilled nursing facility.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Desfibriladores/economia , Remoção de Dispositivo , Alta do Paciente/economia , Infecções Relacionadas à Prótese/cirurgia , Análise Custo-Benefício , Morte Súbita Cardíaca/etiologia , Técnicas de Apoio para a Decisão , Desfibriladores Implantáveis/efeitos adversos , Desfibriladores Implantáveis/economia , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/economia , Remoção de Dispositivo/métodos , Remoção de Dispositivo/mortalidade , Humanos , Avaliação de Processos e Resultados em Cuidados de Saúde , Administração dos Cuidados ao Paciente/economia , Administração dos Cuidados ao Paciente/métodos , Infecções Relacionadas à Prótese/etiologia , Medição de Risco , Estados Unidos