Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Anal Bioanal Chem ; 414(2): 1015-1028, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34750644

RESUMO

The Vitamin D External Quality Assessment Scheme (DEQAS) distributes human serum samples four times per year to over 1000 participants worldwide for the determination of total serum 25-hydroxyvitamin D [25(OH)D)]. These samples are stored at -40 °C prior to distribution and the participants are instructed to store the samples frozen at -20 °C or lower after receipt; however, the samples are shipped to participants at ambient conditions (i.e., no temperature control). To address the question of whether shipment at ambient conditions is sufficient for reliable performance of various 25(OH)D assays, the equivalence of DEQAS human serum samples shipped under frozen and ambient conditions was assessed. As part of a Vitamin D Standardization Program (VDSP) commutability study, two sets of the same nine DEQAS samples were shipped to participants at ambient temperature and frozen on dry ice. Twenty-eight laboratories participated in this study and provided 34 sets of results for the measurement of 25(OH)D using 20 ligand binding assays and 14 liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods. Equivalence of the assay response for the frozen versus ambient DEQAS samples for each assay was evaluated using multi-level modeling, paired t-tests including a false discovery rate (FDR) approach, and ordinary least squares linear regression analysis of frozen versus ambient results. Using the paired t-test and confirmed by FDR testing, differences in the results for the ambient and frozen samples were found to be statistically significant at p < 0.05 for four assays (DiaSorin, DIAsource, Siemens, and SNIBE prototype). For all 14 LC-MS/MS assays, the differences in the results for the ambient- and frozen-shipped samples were not found to be significant at p < 0.05 indicating that these analytes were stable during shipment at ambient conditions. Even though assay results have been shown to vary considerably among different 25(OH)D assays in other studies, the results of this study also indicate that sample handling/transport conditions may influence 25(OH)D assay response for several assays.


Assuntos
Congelamento , Vitamina D/análogos & derivados , Vitamina D/sangue , Cromatografia Líquida/métodos , Humanos , Espectrometria de Massas em Tandem/métodos
2.
Anal Bioanal Chem ; 413(20): 5067-5084, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34184102

RESUMO

An interlaboratory study was conducted through the Vitamin D Standardization Program (VDSP) to assess commutability of Standard Reference Materials® (SRMs) and proficiency testing/external quality assessment (PT/EQA) samples for determination of serum total 25-hydroxyvitamin D [25(OH)D] using ligand binding assays and liquid chromatography-tandem mass spectrometry (LC-MS/MS). A set of 50 single-donor serum samples were assigned target values for 25-hydroxyvitamin D2 [25(OH)D2] and 25-hydroxyvitamin D3 [25(OH)D3] using reference measurement procedures (RMPs). SRM and PT/EQA samples evaluated included SRM 972a (four levels), SRM 2973, six College of American Pathologists (CAP) Accuracy-Based Vitamin D (ABVD) samples, and nine Vitamin D External Quality Assessment Scheme (DEQAS) samples. Results were received from 28 different laboratories using 20 ligand binding assays and 14 LC-MS/MS methods. Using the test assay results for total serum 25(OH)D (i.e., the sum of 25(OH)D2 and 25(OH)D3) determined for the single-donor samples and the RMP target values, the linear regression and 95% prediction intervals (PIs) were calculated. Using a subset of 42 samples that had concentrations of 25(OH)D2 below 30 nmol/L, one or more of the SRM and PT/EQA samples with high concentrations of 25(OH)D2 were deemed non-commutable using 5 of 11 unique ligand binding assays. SRM 972a (level 4), which has high exogenous concentration of 3-epi-25(OH)D3, was deemed non-commutable for 50% of the LC-MS/MS assays.


Assuntos
Sociedades Médicas/normas , Vitamina D/análogos & derivados , Vitamina D/química , Humanos , Padrões de Referência , Manejo de Espécimes , Vitamina D/sangue
3.
Endocrinol Metab Clin North Am ; 46(4): 885-899, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-29080641

RESUMO

Widespread variation in 25-hydroxyvitamin D (25(OH)D) assays continues to compromise efforts to develop clinical and public health guidelines regarding vitamin D status. The Vitamin D Standardization Program helps alleviate this problem. Reference measurement procedures and standard reference materials have been developed to allow current, prospective, and retrospective standardization of 25(OH)D results. Despite advances in 25(OH)D measurement, substantial variability in clinical laboratory 25(OH)D measurement persists. Existing guidelines have not used standardized data and, as a result, it seems unlikely that consensus regarding definitions of vitamin D deficiency, inadequacy, sufficiency, and excess will soon be reached. Until evidence-based consensus is reached, a reasonable clinical approach is advocated.


Assuntos
Deficiência de Vitamina D/diagnóstico , Vitamina D/análogos & derivados , Cromatografia Líquida , Humanos , Padrões de Referência , Espectrometria de Massas em Tandem , Vitamina D/sangue , Deficiência de Vitamina D/sangue
4.
J AOAC Int ; 100(5): 1288-1293, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28797319

RESUMO

The Vitamin D Standardization Program (VDSP) coordinated a study in 2012 to assess the commutability of reference materials and proficiency testing/external quality assurance materials for total 25-hydroxyvitamin D [25(OH)D] in human serum, the primary indicator of vitamin D status. A set of 50 single-donor serum samples as well as 17 reference and proficiency testing/external quality assessment materials were analyzed by participating laboratories that used either immunoassay or LC-MS methods for total 25(OH)D. The commutability test materials included National Institute of Standards and Technology Standard Reference Material 972a Vitamin D Metabolites in Human Serum as well as materials from the College of American Pathologists and the Vitamin D External Quality Assessment Scheme. Study protocols and data analysis procedures were in accordance with Clinical and Laboratory Standards Institute guidelines. The majority of the test materials were found to be commutable with the methods used in this commutability study. These results provide guidance for laboratories needing to choose appropriate reference materials and select proficiency or external quality assessment programs and will serve as a foundation for additional VDSP studies.


Assuntos
Análise Química do Sangue/normas , Ensaio de Proficiência Laboratorial , Vitamina D/análogos & derivados , Humanos , Controle de Qualidade , Padrões de Referência , Estados Unidos , Vitamina D/sangue
5.
J AOAC Int ; 100(5): 1244-1252, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28822355

RESUMO

The Vitamin D Standardization Program (VDSP) coordinated an interlaboratory study to assess the comparability of measurements of total 25-hydroxyvitamin D [25(OH)D] in human serum, which is the primary marker of vitamin D status. A set of 50 individual donor samples were analyzed by 15 different laboratories representing national nutrition surveys, assay manufacturers, and clinical and/or research laboratories to provide results for total 25(OH)D using both immunoassays (IAs) and LC tandem MS (MS/MS). The results were evaluated relative to bias compared with the target values assigned based on a combination of measurements at Ghent University (Belgium) and the U.S. National Institute of Standards and Technology using reference measurement procedures for the determination of 25(OH)D2 and 25(OH)D3. CV and mean bias for each laboratory and assay platform were assessed and compared with previously established VDSP performance criteria, namely CV ≤ 10% and mean bias ≤ 5%. Nearly all LC-MS/MS results achieved VDSP criteria, whereas only 50% of IAs met the criterion for a ≤10% CV and only three of eight IAs achieved the ≤5% bias. These results establish a benchmark for the evaluation of 25(OH)D assay performance and standardization activities in the future.


Assuntos
Análise Química do Sangue/normas , Vitamina D/análogos & derivados , Cromatografia Líquida/normas , Humanos , Imunoensaio/normas , Padrões de Referência , Espectrometria de Massas em Tandem/normas , Vitamina D/sangue
6.
J AOAC Int ; 100(5): 1277-1287, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28847346

RESUMO

Until recently, the Vitamin D External Quality Assessment Scheme (DEQAS) assessed the performance of various assays for the determination of serum total 25-hydroxyvitamin D [25(OH)D] by using a consensus mean based on the all-laboratory trimmed mean (ALTM) of the approximately 1000 participants' results. Since October 2012, the National Institute of Standards and Technology (NIST), as part of the Vitamin D Standardization Program, has participated in DEQAS by analyzing the quarterly serum sample sets using an isotope dilution LC-tandem MS (ID LC-MS/MS) reference measurement procedure to assign an accuracy-based target value for serum total 25(OH)D. NIST has analyzed 90 DEQAS samples (18 exercises × 5 samples/exercise) to assign target values. The NIST-assigned values are compared with the ALTM and the biases assessed for various assays used by the participants, e.g., LC-MS/MS, HPLC, and several ligand-binding assays. The NIST-value assignment process and the results of the analyses of the 90 DEQAS samples are summarized. The absolute mean bias between the NIST-assigned values and the ALTM was 5.6%, with 10% of the samples having biases >10%. Benefits of the accuracy-based target values are presented, including for sample sets with high concentrations of 25(OH)D2 and 3-epi-25(OH)D3.


Assuntos
Análise Química do Sangue/normas , Vitamina D/análogos & derivados , Calcifediol , Cromatografia Líquida de Alta Pressão/normas , Humanos , Espectrometria de Massas em Tandem/normas , Estados Unidos , Vitamina D/sangue
7.
Clin Chem ; 61(4): 636-45, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25710460

RESUMO

BACKGROUND: 24,25-Dihydroxyvitamin D [24,25(OH)2D] in serum may be both a nuisance and nutritionally valuable. METHODS: We investigated the impact of 24,25(OH)2D3 on the performance of commercially available immunoassays for serum total 25-hydroxyvitamin D [25(OH)D] using (a) serum from a nationally representative sample of adults, (b) serum from a spiking experiment, and (c) data from the UK Vitamin D External Quality Assurance Scheme (DEQAS). We also investigated the utility of the serum ratio of 24,25(OH)2D3 to 25(OH)D as an index of inactivation and of response to vitamin D supplementation using randomized controlled trial (RCT) data. Measurement of 24,25(OH)2D in sera by a LC-MS/MS method allowed for an investigation of its impact on immunoassay-derived serum 25(OH)D values as well as its clinical utility. We report data from a nationally representative sample of adults, a recent vitamin D RCT in older adults, and DEQAS. RESULTS: 24,25(OH)2D3 contributed to the positive bias observed in some immunoassays relative to LC-MS/MS-derived estimates for total 25(OH)D. A spiking experiment showed that the degree of cross-reactivity with 24,25(OH)2D was high and may underpin this positive bias. Adjustment for 24,25(OH)2D3 concentration brought estimates closer to true values. Data from the vitamin D RCT showed that the ratio of 24,25(OH)2D3 to 25(OH)D was associated with serum 25(OH)D3 and with response of serum 25(OH)D to vitamin D supplementation. CONCLUSIONS: Our findings highlight that the effect of 24,25(OH)2D3 in serum is a double-edged sword-an interferent for some immunoassays, yet potentially informative of nutritional status.


Assuntos
24,25-Di-Hidroxivitamina D 3/sangue , Técnicas Imunoenzimáticas/normas , Vitamina D/análogos & derivados , Cromatografia Líquida , Reações Cruzadas , Suplementos Nutricionais , Método Duplo-Cego , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Espectrometria de Massas em Tandem , Vitamina D/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA