Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Surg Radiol Anat ; 45(3): 315-319, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36732380

RESUMO

PURPOSE: High-riding jugular bulbs (JBs) among other anatomical variations can limit surgical access during lateral skull base surgery or middle ear surgery and must be carefully assessed preoperatively. We reconstruct 3D surface models to evaluate recent JB classification systems and assess the variability in the JB and surrounding structures. METHODS: 3D surface models were reconstructed from 46 temporal bones from computed tomography scans. Two independent raters visually assessed the height of the JB in the 3D models. Distances between the round window and the JB dome were measured to evaluate the spacing of this area. Additional distances between landmarks on surrounding structures were measured and statistically analyzed to describe the anatomical variability between and within subjects. RESULTS: The visual classification revealed that 30% of the specimens had no JB, 63% a low JB, and 7% a high-riding JB. The measured mean distance from the round window to the jugular bulb ranges between 3.22 ± 0.97 mm and 10.34 ± 1.41 mm. The distance measurement (error rate 5%) was more accurate than the visual classification (error rate 15%). The variability of the JB was higher than for the surrounding structures. No systematic laterality was found for any structure. CONCLUSION: Qualitative analysis in 3D models can contribute to a better spatial orientation in the lateral skull base and, thereby, have important implications during planning of middle ear and lateral skull base surgery.


Assuntos
Veias Jugulares , Procedimentos Neurocirúrgicos , Procedimentos Cirúrgicos Otológicos , Osso Temporal , Humanos , Orelha Média/cirurgia , Veias Jugulares/anatomia & histologia , Veias Jugulares/diagnóstico por imagem , Base do Crânio/diagnóstico por imagem , Base do Crânio/cirurgia , Osso Temporal/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Imageamento Tridimensional , Procedimentos Cirúrgicos Otológicos/métodos , Procedimentos Neurocirúrgicos/métodos , Janela da Cóclea/diagnóstico por imagem , Pesos e Medidas Corporais
2.
World Neurosurg ; 167: e1376-e1386, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36115567

RESUMO

OBJECTIVE: State-of-the-art, minimally invasive endoscopic transcanal surgery of the internal auditory canal (IAC) sacrifices the cochlea with complete hearing loss. With a combination of the transcanal infracochlear and transmastoid retrolabyrinthine approaches, we aim to preserve hearing and enable minimally invasive surgical treatment of vestibular schwannoma. In this study, we investigate the anatomical indications and the feasibility of both approaches in dissections, in human whole head specimens. METHODS: We operated whole head anatomical specimens with a four-handed technique, using the retrolabyrinthine approach as the main surgical corridor and the infracochlear approach for endoscopic visualization. We tested 4 different powered surgical systems. We collected intraoperative data on the size of the access windows, the surgical freedom, and the exposed area of the IAC. Finally, we evaluated the outcome in postoperative computed tomography scans. RESULTS: Six out of 14 sides were anatomically suitable and qualified for the surgery based on preoperative computed tomography. In all attempted sides, the IAC could be reached and opened, leaving the ossicular chain and the labyrinth intact. 51%-75% of the length and 22%-40% of the circumference of the IAC could be exposed. All tested instruments were beneficial at different stages of the surgery. The four-handed technique enabled good maneuverability of the instruments. CONCLUSIONS: The combined multiportal approach to the IAC is feasible with a good surgical exposure and full anatomical preservation of hearing. State-of-the-art surgical instruments in specimens with suitable anatomy are sufficient to perform this approach.


Assuntos
Orelha Interna , Neuroma Acústico , Humanos , Estudos de Viabilidade , Orelha Interna/diagnóstico por imagem , Orelha Interna/cirurgia , Neuroma Acústico/cirurgia , Cóclea/diagnóstico por imagem , Cóclea/cirurgia , Audição
3.
World Neurosurg ; 160: e88-e95, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35026456

RESUMO

OBJECTIVE: Minimally invasive transcanal transpromontorial endoscopic approaches to the internal auditory canal sacrifice the cochlea. Two hearing-preserving approaches, the exclusively endoscopic transcanal infracochlear approach and the endoscope-assisted transmastoid retrolabyrinthine approach, have been controversially discussed in the literature. In this study, we examine the feasibility of these 2 approaches by means of three-dimensional surface models, a population-based analysis of the available surgical space, and dissections in human whole-head specimens. METHODS: We reconstructed three-dimensional surface models based on clinical high-resolution computed tomography scans of 53 adult temporal bones. For both approaches, we measured the maximal extensions and the area of the surgical access windows located between landmarks on the surrounding anatomic structures. We then identified the limiting extensions and derived the cumulative distribution to describe the available surgical space. Dissections were performed to validate the corridors and landmark selection. RESULTS: The limiting extension for the infrachochlear approach is 7.0 ± 2.7 mm from the round window to the dome of the jugular bulb. The limiting extension for the retrolabyrinthine approach is 6.4 ± 1.5 mm from the dura of the posterior fossa to the facial nerve. The cumulative distribution shows that 80% of the cohort have access window extensions ≥3 mm for both approaches. CONCLUSIONS: This study shows that in a high percentage of the measured cohort, the access windows are sufficiently large for endoscopic approaches to the internal auditory canal. With appropriate instrumentation, these hearing-preserving minimally invasive approaches may evolve into alternatives to surgical treatment.


Assuntos
Orelha Interna , Adulto , Orelha Interna/diagnóstico por imagem , Orelha Interna/cirurgia , Endoscópios , Estudos de Viabilidade , Audição , Humanos , Osso Temporal/diagnóstico por imagem , Osso Temporal/cirurgia
4.
Eur Arch Otorhinolaryngol ; 279(6): 2873-2879, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34302212

RESUMO

OBJECTIVE: The alternate cover test (ACT) in patients with acute vestibular syndrome is part of the 'HINTS' battery test. Although quantitative, the ACT is highly dependent on the examiner's experience and could theoretically vary greatly between examiners. In this study, we sought to validate an automated video-oculography (VOG) system based on eye tracking and dedicated glasses. METHODS: We artificially induced a vertical strabismus to simulate a skew deviation on ten healthy subjects, aged from 26 to 66, using different press-on Fresnel prisms on one eye while recording eye position with VOG of the contralateral eye. We then compared the system's performance to that of a blinded trained orthoptist using conventional, semi-quantitative method of skew measurement known as the alternate prism cover test (APCT) as a gold standard. RESULTS: We found a significant correlation between the reference APCT and the Skew VOG (Pearson's R2 = 0.606, p < 0.05). There was a good agreement between the two tests (intraclass correlation coefficient 0.852, 95 CI 0.728-0.917, p < 0.001). The overall accuracy of the VOG was estimated at 80.53% with an error rate of 19.46%. There was no significant difference in VOG skew estimations compared with the gold standard except for very small skews. CONCLUSIONS: VOG offers an objective and quantitative skew measurement and proved to be accurate in measuring vertical eye misalignment compared to the ACT with prisms. Precision was moderate, which mandates a sufficient number of tests per subject.


Assuntos
Estrabismo , Humanos , Estrabismo/diagnóstico , Inquéritos e Questionários , Vertigem
5.
Front Surg ; 8: 736217, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34660679

RESUMO

Introduction: Current high-accuracy image-guided systems for otologic surgery use fiducial screws for patient-to-image registration. Thus far, these systems have only been used in adults, and the safety and efficacy of the fiducial screw placement has not yet been investigated in the pediatric population. Materials and Methods: In a retrospective study, CT image data of the temporal region from 11 subjects meeting inclusion criteria (8-48 months at the time of surgery) were selected, resulting in n = 20 sides. These datasets were investigated with respect to screw stability efficacy in terms of the cortical layer thickness, and safety in terms of the distance of potential fiducial screws to the dura mater or venous sinuses. All of these results are presented as distributions, thickness color maps, and with descriptive statistics. Seven regions within the temporal bone were analyzed individually. In addition, four fiducial screws per case with 4 mm thread-length were placed in an additively manufactured model according to the guidelines for robotic cochlear implantation surgery. For all these screws, the minimal distance to the dura mater or venous sinuses was measured, or if applicable how much they penetrated these structures. Results: The cortical layer has been found to be mostly between 0.7-3.3 mm thick (from the 5th to the 95th percentile), while even thinner areas exist. The distance from the surface of the temporal bone to the dura mater or the venous sinuses varied considerably between the subjects and ranged mostly from 1.1-9.3 mm (from the 5th to the 95th percentile). From all 80 placed fiducial screws of 4 mm thread length in the pediatric subject younger than two years old, 22 touched or penetrated either the dura or the sigmoid sinus. The best regions for fiducial placement would be the mastoid area and along the petrous pyramid in terms of safety. In terms of efficacy, the parietal followed by the petrous pyramid, and retrosigmoid regions are most suited. Conclusion: The current fiducial screws and the screw placement guidelines for adults are insufficiently safe or effective for pediatric patients.

6.
Clin Oral Implants Res ; 31(5): 463-475, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31991010

RESUMO

OBJECTIVES: To compare ear, nose, and throat (ENT) specialists and dentists assessing health or pathology of maxillary sinuses using cone beam computed tomography (CBCT). MATERIAL AND METHODS: Two ENT specialists and two oral surgeons assessed 100 CBCT datasets of healthy patients referred for dental implant placement in the posterior maxilla and decided on the possibility of sinus floor elevation or the necessity for further diagnostic examinations based solely on radiographic findings. Inter-rater agreements within the same specialty were calculated with Cohen's kappa and overall agreements with Fleiss kappa, and factors influencing the decisions taken were evaluated using regression analyses. RESULTS: The correlation between all four raters was generally fair to moderate. The intra-specialty comparison showed a lower correlation between dentists than between ENT specialists. Absence of membrane thickening and total or subtotal sinus opacification showed the highest predictive value for a consensus in favor of sinus floor elevation and ENT referral, respectively. Flat membrane thickening with an irregular surface morphology was associated with disagreement between the examiners. Dome-shaped membrane thickenings were often considered as to be referred by dentists but not by ENTs. CONCLUSION: The assessment of maxillary sinuses using CBCT imaging exhibited unsatisfactory agreement between ENT specialists and oral surgeons. Referral guidelines based on accidental CBCT findings that aim to diagnose relevant sinus pathologies early and avoid unnecessary diagnostics and/or therapies are needed, and an initial proposal for such recommendations is provided. Further research on correct interpretation of sinus findings and a validation of the present recommendations are required.


Assuntos
Seio Maxilar , Levantamento do Assoalho do Seio Maxilar , Tomografia Computadorizada de Feixe Cônico , Odontólogos , Humanos , Faringe , Encaminhamento e Consulta , Especialização
7.
Artigo em Inglês | MEDLINE | ID: mdl-31743900

RESUMO

INTRODUCTION: The management of bleeding in exclusive endoscopic ear surgery (EES) is largely dependent on epinephrine use. However, to date its suitability and safety have not been assessed. The aim of the present study would be to assess the safety profile of topical application and/or local infiltrationof diluted epinephrine during EES regarding the intra- and postoperative periods. We hypothesize that epinephrine may be safely used during EES. METHODS: Retrospective analysis of 90 EES cases performed at the University Hospital of Modena, Italy. Patient's charts and video recordings of the operations were assessed. RESULTS: Epinephrine was used in all cases for hemostatic purposes as following: (1) diluted epinephrine (1:200,000) injection: mean 1.2 mL (range: 0-3.5) corresponding to 0.006 mg (range 0-0.018), and (2) topical application (1:1,000) directly in the surgical field: mean 7 cottonoids (range: 0-18) corresponding to mean 0.56 mg (range: 0-1.44). No major cardiovascular adverse effects were assessed. Only 2 intraoperative hypertensive events were recorded. One sensorineural hearing loss was observed in a case of cholesteatoma involving the stapes; no facial palsy occurred during the study period. CONCLUSION: The combined use of local injection and topical epinephrine is a safe and effective strategy to control bleeding in exclusive EES, when used within the dilutions and quantities reported in this study.


Assuntos
Epinefrina , Hemorragia , Procedimentos Cirúrgicos Otológicos , Vasoconstritores , Colesteatoma , Endoscopia , Epinefrina/uso terapêutico , Hemorragia/etiologia , Hemorragia/prevenção & controle , Humanos , Procedimentos Cirúrgicos Otológicos/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Vasoconstritores/uso terapêutico
8.
JAMA Otolaryngol Head Neck Surg ; 145(9): 838-845, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31343675

RESUMO

IMPORTANCE: Endoscopic ear surgery (EES) is an emerging technique to treat middle ear diseases; however, the interventions are performed in 2-dimensional (2D) endoscopic views, which do not provide depth perception. Recent technical developments now allow the application of 3-dimensional (3D) endoscopy in EES. OBJECTIVE: To investigate the usability, advantages, and disadvantages of 3D vs 2D endoscopy in EES under standardized conditions. DESIGN, SETTING, AND PARTICIPANTS: This cohort study conducted at a tertiary academic medical center in Bern, Switzerland, included 16 residents and consultants of the Department of Otorhinolaryngology, Head & Neck Surgery, Inselspital, Bern. INTERVENTIONS: Each participant performed selected steps of a type I tympanoplasty and stapedotomy in 3D and 2D views in a cadaveric model using a randomized, Latin-square crossover design. MAIN OUTCOMES AND MEASURES: Time taken to perform the EES, number of attempts, and accidental damage during the dissections were compared between 3D and 2D endoscopy. Eye tracking was performed throughout the interventions. Cognitive load and subjective feedback were measured by standardized questionnaires. RESULTS: Of the 16 surgeons included in the study (11 inexperienced residents; 5 experienced consultants), 8 were women (50%); mean age was 36 years (range, 27-57 years). Assessment of surgical time revealed similar operating times for both techniques (181 seconds in 2D vs 174 seconds in 3D). A total of 64 surgical interventions were performed. Most surgeons preferred the 3D technique (10 for 3D vs 6 for 2D), even though a higher incidence of eye strain, measured on a 7-point Likert scale, was observed (3D, 2.19 points vs 2D, 1.44 points; mean difference , 0.74; 95% CI, 0.29-1.20; r = 0.67). Eye movement assessment revealed a higher duration of fixation for consultants in 2D (0.79 seconds) compared with 3D endoscopy (0.54 seconds), indicating a less-efficient application of previously acquired experiences using the new technique. Residents (mean [SD], 49.02 [16.4]) had a significantly higher workload than consultants (mean [SD], 27.21 [12.20]), independent of the used technique or task. CONCLUSIONS AND RELEVANCE: Three-dimensional endoscopy is suitable for EES, especially for inexperienced surgeons whose mental model of the intervention has yet to be consolidated. The application of 3D endoscopy in clinical routines and for educational purposes may be feasible and beneficial.

9.
Anat Sci Educ ; 12(5): 507-517, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30430760

RESUMO

Teaching methodologies for the anatomy of the middle ear have not been investigated greatly due to the middle ear's highly complex structure and hidden location inside of the temporal bone. The aim of this randomized study was to quantitatively compare the suitability of using microscope- and endoscope-based methods for teaching the anatomy of the middle ear. We hypothesize that the endoscopic approach will be more efficient compared to the microscopic approach. To answer the study questions, 33 sixth-year medical students, residents and otorhinolaryngology specialists were randomized either into the endoscopy or the microscopy group. Their anatomical knowledge was assessed using a structured anatomical knowledge test before and after each session. Each participant received tutoring on a human cadaveric specimen using one of the two methods. They then performed a hands-on dissection. After 2-4 weeks, the same educational curriculum was repeated using the other technique. The mean gains in anatomical knowledge for the specialists, residents, and medical students were +19.0%, +34.6%, and +23.4%, respectively. Multivariate analyses identified a statistically significant increase in performance for the endoscopic method compared to the microscopic technique (P < 0.001). For the recall of anatomical structures during dissection, the endoscopic method outperformed the microscopic technique independently of the randomization or the prior training level of the attendees (P < 0.001). In conclusion, the endoscopic approach to middle ear anatomy education is associated to an improved gain in knowledge as compared to the microscopic approach. The participants subjectively preferred the endoscope for educational purposes.


Assuntos
Anatomia/educação , Orelha Média/anatomia & histologia , Ensino , Adulto , Cadáver , Currículo , Dissecação , Orelha Média/diagnóstico por imagem , Educação Médica Continuada/métodos , Educação Médica Continuada/estatística & dados numéricos , Educação de Graduação em Medicina/métodos , Educação de Graduação em Medicina/estatística & dados numéricos , Avaliação Educacional/estatística & dados numéricos , Endoscopia , Feminino , Humanos , Internato e Residência/métodos , Internato e Residência/estatística & dados numéricos , Masculino , Rememoração Mental , Microscopia , Pessoa de Meia-Idade , Avaliação de Programas e Projetos de Saúde , Distribuição Aleatória , Estudantes de Medicina/estatística & dados numéricos , Cirurgiões/educação , Cirurgiões/estatística & dados numéricos , Adulto Jovem
10.
Otol Neurotol ; 38(5): 759-764, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28196000

RESUMO

HYPOTHESIS: Descriptive statistics with respect to patient anatomy and image guidance accuracy can be used to assess the effectiveness of any system for minimally invasive cochlear implantation, on both an individual patient and wider population level. BACKGROUND: Minimally invasive cochlear implantation involves the drilling of a tunnel from the surface of the mastoid to cochlea, with the trajectory passing through the facial recess. The facial recess anatomy constrains the drilling path and places prohibitive accuracy requirements on the used system. Existing single thresholds are insufficient for assessing the effectiveness of these systems. METHODS: A statistical model of the anatomical situation encountered during minimally invasive drilling of the mastoid for cochlear implantation was developed. A literature review was performed to determine the statistical distribution of facial recess width; these values were confirmed through facial recess measurements on computed tomography (CT) data. Based on the accuracy of a robotic system developed by the authors, the effect of variation of system accuracy, precision, and tunnel diameter examined with respect to the potential treatable portion of the population. RESULTS: A facial recess diameter of 2.54 ±â€Š0.51 mm (n = 74) was determined from a review of existing literature; subsequent measurements on CT data revealed a facial recess diameter of 2.54 ±â€Š0.5 mm (n = 23). The developed model demonstrated the effects of varying accuracy on the treatable portion of the population. CONCLUSIONS: The presented model allows the assessment of the applicability of a system on a wider population scale beyond examining only the system's ability to reach an arbitrary threshold accuracy.


Assuntos
Implante Coclear/métodos , Modelos Estatísticos , Procedimentos Cirúrgicos Robóticos/métodos , Cirurgia Assistida por Computador/métodos , Cóclea/diagnóstico por imagem , Cóclea/cirurgia , Humanos , Processo Mastoide/diagnóstico por imagem , Processo Mastoide/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Robótica , Tomografia Computadorizada por Raios X
11.
Acta Otolaryngol ; 127(4): 403-7, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17453461

RESUMO

CONCLUSION: Our self-developed planning and navigation system has proven its capacity for accurate surgery on the anterior and lateral skull base. With the incorporation of augmented reality, image-guided surgery will evolve into 'information-guided surgery'. OBJECTIVE: Microscopic or endoscopic skull base surgery is technically demanding and its outcome has a great impact on a patient's quality of life. The goal of the project was aimed at developing and evaluating enabling navigation surgery tools for simulation, planning, training, education, and performance. This clinically applied technological research was complemented by a series of patients (n=406) who were treated by anterior and lateral skull base procedures between 1997 and 2006. MATERIALS AND METHODS: Optical tracking technology was used for positional sensing of instruments. A newly designed dynamic reference base with specific registration techniques using fine needle pointer or ultrasound enables the surgeon to work with a target error of < 1 mm. An automatic registration assessment method, which provides the user with a color-coded fused representation of CT and MR images, indicates to the surgeon the location and extent of registration (in)accuracy. Integration of a small tracker camera mounted directly on the microscope permits an advantageous ergonomic way of working in the operating room. Additionally, guidance information (augmented reality) from multimodal datasets (CT, MRI, angiography) can be overlaid directly onto the surgical microscope view. The virtual simulator as a training tool in endonasal and otological skull base surgery provides an understanding of the anatomy as well as preoperative practice using real patient data. RESULTS: Using our navigation system, no major complications occurred in spite of the fact that the series included difficult skull base procedures. An improved quality in the surgical outcome was identified compared with our control group without navigation and compared with the literature. The surgical time consumption was reduced and more minimally invasive approaches were possible. According to the participants' questionnaires, the educational effect of the virtual simulator in our residency program received a high ranking.


Assuntos
Otopatias/cirurgia , Neuronavegação/instrumentação , Doenças Nasais/cirurgia , Doenças dos Seios Paranasais/cirurgia , Base do Crânio/cirurgia , Braquiterapia/instrumentação , Angiografia Cerebral/instrumentação , Simulação por Computador , Processamento Eletrônico de Dados/instrumentação , Endoscopia , Desenho de Equipamento , Humanos , Processamento de Imagem Assistida por Computador/instrumentação , Imageamento Tridimensional/instrumentação , Internato e Residência , Imageamento por Ressonância Magnética/instrumentação , Microcirurgia/instrumentação , Otolaringologia/educação , Imagens de Fantasmas , Complicações Pós-Operatórias/etiologia , Sensibilidade e Especificidade , Software , Técnicas Estereotáxicas/instrumentação , Avaliação da Tecnologia Biomédica , Tomografia Computadorizada por Raios X/instrumentação , Interface Usuário-Computador
12.
Clin Oral Implants Res ; 16(1): 53-9, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15642031

RESUMO

A novel methodology which allows for fast and fully automatic structural analysis during preoperative planning for dental implant surgery is presented. This method integrates a fully automatic fast finite element solver within the framework of new concepts in computer-assisted preoperative planning for implant surgery. The planning system including optimized structural planning was validated by experimental results. Nine implants were placed in pig mandibles and mechanically loaded using a testing rig. The resulting displacements were measured and compared with those predicted by numerical analysis during planning. The results show that there were no statistically significant differences (P = 0.65) between the results of the models and the experiments. The results show that fast structural analysis can be integrated with surgical planning software allowing the initial axial implant stability to be predicted in real time during planning. It is believed that such a system could be used to select patients for immediate implant loading and, when further developed, be useful in other areas of preoperative surgical planning.


Assuntos
Simulação por Computador , Implantação Dentária Endóssea/métodos , Implantes Dentários , Análise do Estresse Dentário/métodos , Cirurgia Assistida por Computador/métodos , Animais , Força Compressiva , Sistemas Computacionais , Retenção em Prótese Dentária , Elasticidade , Análise de Elementos Finitos , Arcada Edêntula/diagnóstico por imagem , Validação de Programas de Computador , Suínos , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA