Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Semin Arthritis Rheum ; 65: 152406, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38401294

RESUMO

OBJECTIVES: Over the last years ultrasound has shown to be an important tool for evaluating lung involvement, including interstitial lung disease (ILD) a potentially severe systemic involvement in many rheumatic and musculoskeletal diseases (RMD). Despite the potential sensitivity of the technique the actual use is hampered by the lack of consensual definitions of elementary lesions to be assessed and of the scanning protocol to apply. Within the Outcome Measures in Rheumatology (OMERACT) Ultrasound Working Group we aimed at developing consensus-based definitions for ultrasound detected ILD findings in RMDs and assessing their reliability in dynamic images. METHODS: Based on the results from a systematic literature review, several findings were identified for defining the presence of ILD by ultrasound (i.e., Am-lines, B-lines, pleural cysts and pleural line irregularity). Therefore, a Delphi survey was conducted among 23 experts in sonography to agree on which findings should be included and on their definitions. Subsequently, a web-reliability exercise was performed to test the reliability of the agreed definitions on video-clips, by using kappa statistics. RESULTS: After three rounds of Delphi an agreement >75 % was obtained to include and define B-lines and pleural line irregularity as elementary lesions to assess. The reliability in the web-based exercise, consisting of 80 video-clips (30 for pleural line irregularity, 50 for B-lines), showed moderate inter-reader reliability for both B-lines (kappa = 0.51) and pleural line irregularity (kappa = 0.58), while intra-reader reliability was good for both B-lines (kappa = 0.72) and pleural line irregularity (kappa = 0.75). CONCLUSION: Consensus-based ultrasound definitions for B-lines and pleural line irregularity were obtained, with moderate to good reliability to detect these lesions using video-clips. The next step will be testing the reliability in patients with ILD linked to RMDs and to propose a consensual and standardized protocol to scan such patients.


Assuntos
Gota , Doenças Pulmonares Intersticiais , Doenças Musculares , Humanos , Reprodutibilidade dos Testes , Ultrassonografia/métodos , Doenças Pulmonares Intersticiais/diagnóstico por imagem , Padrões de Referência
2.
Rheumatology (Oxford) ; 61(12): 4863-4874, 2022 11 28.
Artigo em Inglês | MEDLINE | ID: mdl-35293988

RESUMO

OBJECTIVES: To investigate the reliability of the OMERACT US Task Force definition of US enthesitis in SpA. METHODS: In this web exercise, based on the evaluation of 101 images and 39 clips of the main entheses of the lower limbs, the elementary components included in the OMERACT definition of US enthesitis in SpA (hypoechoic areas, entheseal thickening, power Doppler signal at the enthesis, enthesophytes/calcifications, bone erosions) were assessed by 47 rheumatologists from 37 rheumatology centres in 15 countries. Inter- and intra-observer reliability of the US components of enthesitis was calculated using Light's kappa, Cohen's kappa, Prevalence And Bias Adjusted Kappa (PABAK) and their 95% CIs. RESULTS: Bone erosions and power Doppler signal at the enthesis showed the highest overall inter-reliability [Light's kappa: 0.77 (0.76-0.78), 0.72 (0.71-0.73), respectively; PABAK: 0.86 (0.86-0.87), 0.73 (0.73-0.74), respectively], followed by enthesophytes/calcifications [Light's kappa: 0.65 (0.64-0.65), PABAK: 0.67 (0.67-0.68)]. This was moderate for entheseal thickening [Light's kappa: 0.41 (0.41-0.42), PABAK: 0.41 (0.40-0.42)], and fair for hypoechoic areas [Light's kappa: 0.37 (0.36-0.38); PABAK: 0.37 (0.37-0.38)]. A similar trend was observed in the intra-reliability exercise, although this was characterized by an overall higher degree of reliability for all US elementary components compared with the inter-observer evaluation. CONCLUSIONS: The results of this multicentre, international, web-based study show a good reliability of the OMERACT US definition of bone erosions, power Doppler signal at the enthesis and enthesophytes/calcifications. The low reliability of entheseal thickening and hypoechoic areas raises questions about the opportunity to revise the definition of these two major components for the US diagnosis of enthesitis.


Assuntos
Entesopatia , Humanos , Reprodutibilidade dos Testes , Entesopatia/diagnóstico por imagem , Ultrassonografia/métodos , Ultrassonografia Doppler/métodos , Internet
3.
Front Med (Lausanne) ; 9: 1090468, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36733934

RESUMO

Objectives: To investigate the inter/intra-reliability of ultrasound (US) muscle echogenicity in patients with rheumatic diseases. Methods: Forty-two rheumatologists and 2 radiologists from 13 countries were asked to assess US muscle echogenicity of quadriceps muscle in 80 static images and 20 clips from 64 patients with different rheumatic diseases and 8 healthy subjects. Two visual scales were evaluated, a visual semi-quantitative scale (0-3) and a continuous quantitative measurement ("VAS echogenicity," 0-100). The same assessment was repeated to calculate intra-observer reliability. US muscle echogenicity was also calculated by an independent research assistant using a software for the analysis of scientific images (ImageJ). Inter and intra reliabilities were assessed by means of prevalence-adjusted bias-adjusted Kappa (PABAK), intraclass correlation coefficient (ICC) and correlations through Kendall's Tau and Pearson's Rho coefficients. Results: The semi-quantitative scale showed a moderate inter-reliability [PABAK = 0.58 (0.57-0.59)] and a substantial intra-reliability [PABAK = 0.71 (0.68-0.73)]. The lowest inter and intra-reliability results were obtained for the intermediate grades (i.e., grade 1 and 2) of the semi-quantitative scale. "VAS echogenicity" showed a high reliability both in the inter-observer [ICC = 0.80 (0.75-0.85)] and intra-observer [ICC = 0.88 (0.88-0.89)] evaluations. A substantial association was found between the participants assessment of the semi-quantitative scale and "VAS echogenicity" [ICC = 0.52 (0.50-0.54)]. The correlation between these two visual scales and ImageJ analysis was high (tau = 0.76 and rho = 0.89, respectively). Conclusion: The results of this large, multicenter study highlighted the overall good inter and intra-reliability of the US assessment of muscle echogenicity in patients with different rheumatic diseases.

4.
J Clin Rheumatol ; 24(4): 218-223, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29239938

RESUMO

OBJECTIVE: There are different imaging techniques to assess the parotid glands (i.e., sialography, salivary gland scintigraphy) in patients with Sjögren syndrome (SS). However, their use is limited by the invasive character or high cost. Ultrasound (US) is gaining interest by rheumatologists as a complementary diagnostic tool for SS. To date, there is an increasing body of evidence supporting its sensitivity in the assessment of salivary glands in SS. The aim of our study was to analyze the potential role of US as a diagnostic and prognostic tool in SS and to discuss existing evidence to support its application use. METHODS: A systematic search was performed in the electronic database PubMed, using the following search terms: (salivary glands OR parotid glands OR submandibular glands) AND Sjögren's syndrome AND (ultrasonography OR ultrasound OR sonography). Titles, abstracts, and full reports were systematically screened. RESULTS: The results of the studies analyzed in this review show encouraging results in terms of accuracy, validity, and diagnostic value, which leads us to believe that in the future US could become the reference imaging tool to assess SS. The studies include a small cohort of patients, and there is no standardized approach in terms of US techniques for the assessment of salivary glands. CONCLUSIONS: Ultrasound of major salivary glands is a useful tool for diagnosis, prognostic evaluation, and response to treatment in SS. The use of this imaging technology is still under development, and more multicentric studies are needed to validate this tool.


Assuntos
Glândulas Salivares/diagnóstico por imagem , Síndrome de Sjogren/diagnóstico por imagem , Ultrassonografia , Humanos
5.
J Clin Rheumatol ; 21(8): 435-9, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26513305

RESUMO

The First PANLAR Rheumatology Review Course was held in Barranquilla, Colombia, in April 2015. Researchers, rheumatologists, epidemiologists, and a variety of allied professionals and patients attended the meeting. The scientific program included plenary sessions and symposia delivered by renowned experts in the field, followed by an interactive forum of discussion during 2 days.A broad spectrum of topics was discussed, reflecting the current challenges and opportunities for diagnosis and treatment of rheumatoid arthritis (RA) in Latin America. The scientific program included not only traditional disease aspects, but also social implications, research projects, and educational characteristics, patient perspectives, and novel care models, emphasizing the need for training human resources and proposing unique approaches to RA health care in Latin America, therefore helping us to increase and improve the knowledge and understanding of the characteristics of this health condition in the region, thus promoting and encouraging equity, quality, and efficiency of RA health care.


Assuntos
Artrite Reumatoide , Atenção à Saúde , Educação de Pacientes como Assunto , Reumatologia , Desenvolvimento de Pessoal , Antirreumáticos/uso terapêutico , Artrite Reumatoide/diagnóstico , Artrite Reumatoide/terapia , Atenção à Saúde/métodos , Atenção à Saúde/organização & administração , Gerenciamento Clínico , Humanos , América Latina , Melhoria de Qualidade , Reumatologia/educação , Reumatologia/métodos , Fatores Socioeconômicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA