1.
Phys Eng Sci Med ; 46(3): 1193-1204, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37358782

RESUMO

High-density catheters combined with Orientation Independent Sensing (OIS) methods have emerged as a groundbreaking technology for cardiac substrate characterisation. In this study, we aim to assess the arrangements and constraints to reliably estimate the so-called omnipolar electrogram (oEGM). Performance was evaluated using an experimental animal model. Thirty-eight recordings from nine retrospective experiments on isolated perfused rabbit hearts with an epicardial HD multielectrode were used. We estimated oEGMs according to the classic triangular clique (4 possible orientations) and a novel cross-orientation clique arrangement. Furthermore, we tested the effects of interelectrode spacing from 1 to 4 mm. Performance was evaluated by means of several parameters that measured amplitude rejection ratios, electric field loop area, activation pulse width and morphology distortion. Most reliable oEGM estimations were obtained with cross-configurations and interelectrode spacings [Formula: see text] mm. Estimations from triangular cliques resulted in wider electric field loops and unreliable detection of the direction of the propagation wavefront. Moreover, increasing interelectrode distance resulted in increased pulse width and morphology distortion. The results prove that current oEGM estimation techniques are insufficiently accurate. This study opens a new standpoint for the design of new-generation HD catheters and mapping software.


Assuntos
Coração , Software , Animais , Coelhos , Estudos Retrospectivos , Eletrodos , Modelos Animais
2.
Biomed Tech (Berl) ; 52(1): 25-30, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17313330

RESUMO

In recent decades, implantable cardioverter defibrillators (ICDs) have improved substantially, becoming the treatment of choice for patients at high risk of life-threatening arrhythmias. Nevertheless, inappropriate shock therapy for non-ventricular arrhythmias is still a problem. Extending the ICD battery lifetime demands very low power consumption, which is obtained at very low microprocessor clock frequencies. Currently, some high-performance algorithms remain beyond the computational capabilities of ICDs. Future ICDs with higher computing power will permit the implementation of computationally intensive algorithms, enhancing the discrimination performance and preventing inappropriate shock therapies. An ICD algorithm status review is presented from the point of view of signal processing techniques and their computational costs. Several examples of discrimination algorithms with increasing computational cost are analyzed. Whereas some of them are already used in commercial ICDs, other algorithms cannot be implemented yet in current ICDs. A solution based on dynamic adaptation of microprocessor power consumption to meet algorithm computational requirements is proposed. This solution allows implementation of complex discrimination algorithms in ICDs without significantly increasing the power consumption.


Assuntos
Algoritmos , Desfibriladores Implantáveis , Diagnóstico por Computador/métodos , Cardioversão Elétrica/instrumentação , Eletrocardiografia/métodos , Terapia Assistida por Computador/métodos , Diagnóstico por Computador/tendências , Cardioversão Elétrica/métodos , Cardioversão Elétrica/tendências , Eletrocardiografia/tendências , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Software , Terapia Assistida por Computador/tendências , Sistema Vasomotor/fisiologia
SELEÇÃO DE REFERÊNCIAS