Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Eur J Clin Microbiol Infect Dis ; 40(10): 2235-2241, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33782783

RESUMO

We report evaluation of 30 assays' (17 rapid tests (RDTs) and 13 automated/manual ELISA/CLIA assay (IAs)) clinical performances with 2594 sera collected from symptomatic patients with positive SARS-CoV-2 rRT-PCR on a respiratory sample, and 1996 pre-epidemic serum samples expected to be negative. Only 4 RDT and 3 IAs fitted both specificity (> 98%) and sensitivity (> 90%) criteria according to French recommendations. Serology may offer valuable information during COVID-19 pandemic, but inconsistent performances observed among the 30 commercial assays evaluated, which underlines the importance of independent evaluation before clinical implementation.


Assuntos
Anticorpos Antivirais/sangue , Teste Sorológico para COVID-19/métodos , COVID-19/sangue , Imunoensaio/métodos , SARS-CoV-2/imunologia , COVID-19/virologia , Humanos , Imunoensaio/economia , Imunoglobulina M/sangue , Kit de Reagentes para Diagnóstico , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , Sensibilidade e Especificidade
2.
J Infect Dis ; 216(3): 382-386, 2017 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-28666370

RESUMO

Preexposure prophylaxis programs involve frequent human immunodeficiency virus (HIV) testing. We evaluated the sensitivity of 2 antigen/antibody immunoassays (Architect and Bioplex), 2 antibody-based rapid tests (Vikia-HIV-1/2 and Autotest-VIH), and 1 antigen/antibody rapid test (Alere HIV Combo) for the diagnosis of HIV infection. Among the 31 HIV-1-infected participants in the ANRS-IPERGAY trial, HIV-1 RNA was detected alone in only 2. The sensitivities of the Architect and Bioplex assays were 83% (95% confidence interval [CI], 76%-99%) and 82% (95% CI, 63%-94%), respectively. The sensitivities of the Vikia, Autotest, and Alere tests were 54% (95% CI, 34%-72%), 50% (95% CI, 31%-69%), and 78% (95% CI, 58%-91%), respectively. Antigen/antibody tests should be preferred to avoid missing cases of acute HIV infection and to decrease the related risks of viral transmission and emergence of drug resistance.


Assuntos
Infecções por HIV/diagnóstico , Infecções por HIV/prevenção & controle , Imunoensaio/métodos , Profilaxia Pré-Exposição , Anticorpos Anti-HIV/sangue , Antígenos HIV/sangue , HIV-1 , Humanos , Programas de Rastreamento/métodos , RNA Viral/sangue , Estudos Retrospectivos , Sensibilidade e Especificidade , Testes Sorológicos
3.
J Clin Microbiol ; 43(6): 2709-17, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15956387

RESUMO

There is an urgent need for low-cost human immunodeficiency virus type 1 (HIV-1) viral load (VL) monitoring technologies in resource-limited settings. An automated TaqMan real-time reverse transcription-PCR (RT-PCR) assay was transferred to the laboratory of the Centre de Diagnostic et de Recherches sur le SIDA, Abidjan, Côte d'Ivoire, and assessed for HIV-1 RNA VL testing in 806 plasma samples collected within four ANRS research programs. The detection threshold and reproducibility of the assay were first determined. The quantitative results obtained with this assay were compared with two commercial HIV-1 RNA kits (the Versant version 3.0 and Monitor version 1.5 assays) in specimens harboring mainly the circulating recombinant form 02 strain (CRF02). The clinical evaluation of this test was done in different situations including the early diagnosis of pediatric infection and the monitoring of antiretroviral-treated patients. The quantification limit of our method was 300 copies/ml. The HIV-1 RNA values obtained by real-time PCR assay were highly correlated with those obtained by the Versant kit (r = 0.901; P < 0.001) and the Monitor test (r = 0.856; P < 0.001) and homogeneously distributed according to HIV-1 genotypes. For the early diagnosis of pediatric HIV-1 infection, the sensitivity and specificity of the real-time PCR assay were both 100% (95% confidence intervals of 93.7 to 100.0 and 98.3 to 100.0, respectively), compared to the Versant results. Following initiation of antiretroviral treatment, the kinetics of HIV-1 RNA levels were very comparable, with a similar proportion of adults and children below the detection limit during follow-up with our technique and the Versant assay. The TaqMan real-time PCR (12 dollars per test) is now routinely used to monitor HIV-1 infection in our laboratory. This technology should be further evaluated in limited-resource countries where strains other than CRF02 are prevalent.


Assuntos
Infecções por HIV/diagnóstico , Infecções por HIV/tratamento farmacológico , HIV-1/fisiologia , RNA Viral/sangue , Reação em Cadeia da Polimerase Via Transcriptase Reversa/economia , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Terapia Antirretroviral de Alta Atividade , Criança , Pré-Escolar , Côte d'Ivoire , Países em Desenvolvimento , Infecções por HIV/virologia , HIV-1/classificação , HIV-1/genética , Humanos , Kit de Reagentes para Diagnóstico , Recombinação Genética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA