Resultados 1 - 7 de 7
Filtrar
1.
J Appl Clin Med Phys ; 24(12): e14149, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37738654

RESUMO

To investigate the effect of using non-uniform loading and notched plaques on dose distribution for eye plaques. Using EGSnrc Monte Carlo (MC) simulations, we investigate eye plaque dose distributions in water and in an anatomically representative eye phantom. Simulations were performed in accordance with TG43 formalism and compared against full MC simulations which account for inter-seed and inhomogeneity effects. For standard plaque configurations, uniformly and non-uniformly loaded plaque dose distributions in water showed virtually no difference between each other. For standard plaque, the MC calculated dose distribution in planes parallel to the plaque is narrower than the TG43 calculation due to attenuation at the periphery of the plaque by the modulay. MC calculated the dose behind the plaque is fully attenuated. Similar results were found for the notched plaque, with asymmetric attenuation along the plane of the notch. Cumulative dose volume histograms showed significant reductions in the calculated MC doses for both tumor and eye structures, compared to TG43 calculations. The effect was most pronounced for the notch plaque where the MC dose to the optic nerve was greatly attenuated by the modulay surrounding the optic nerve compared to the TG43. Thus, a reduction of optic nerve D95% from 14 to 0.2 Gy was observed, when comparing the TG43 calculation to the MC result. The tumor D95% reduced from 89.2 to 79.95 Gy for TG43 and MC calculations, respectively. TG43 calculations overestimate the absolute dose and the lateral dose distribution of both standard and notched eye plaques, leading to the dose overestimation for the target and organs at risk. The dose matching along the central axis for the non-uniformly loaded plaques to that of uniformly loaded ones was found to be sufficient for providing comparable coverage and can be clinically used in eye-cancer-busy centers.


Assuntos
Braquiterapia , Neoplasias Oculares , Humanos , Radiometria/métodos , Braquiterapia/métodos , Neoplasias Oculares/radioterapia , Método de Monte Carlo , Água , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos
2.
Med Phys ; 50(3): 1928-1941, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36542404

RESUMO

PURPOSE: To update and extend version 2 of the Carleton Laboratory for Radiotherapy Physics (CLRP) TG-43 dosimetry database (CLRP_TG43v2) for high-energy (HE, ≥50 keV) brachytherapy sources (1 169 Yb, 23 192 Ir, 5 137 Cs, and 4 60 Co) using egs_brachy, an open-source EGSnrc application. A comprehensive dataset of TG-43 parameters is compiled, including detailed source descriptions, dose-rate constants, radial dose functions, 1D and 2D anisotropy functions, along-away dose-rate tables, Primary and Scatter Separated (PSS) dose tables, and mean photon energies escaping each source. The database also documents the source models which are freely distributed with egs_brachy. ACQUISITION AND VALIDATION METHODS: Datasets are calculated after a recoding of the source geometries using the egs++ geometry package and its egs_brachy extensions. Air kerma per history is calculated in a 10 × 10 × $\,{\times}\, 10\,{\times}\,$ 0.05 cm3 voxel located 100 cm from the source along the transverse axis and then corrected for the lateral and thickness dimensions of the scoring voxel to give the air kerma on the central axis at a point 100 cm from the source's mid-point. Full-scatter water phantoms with varying voxel resolutions in cylindrical coordinates are used for dose calculations. Most data (except for 60 Co) are based on the assumption of charged particle equilibrium and ignore the potentially large effects of electron transport very close to the source and dose from initial beta particles. These effects are evaluated for four representative sources. For validation, data are compared to those from CLRP_TG43v1 and published data. DATA FORMAT AND ACCESS: Data are available at https://physics.carleton.ca/clrp/egs_brachy/seed_database_v2 or http://doi.org/10.22215/clrp/tg43v2 including in Excel (.xlsx) spreadsheets, and are presented graphically in comparisons to previously published data for each source. POTENTIAL APPLICATIONS: The CLRP_TG43v2 database has applications in research, dosimetry, and brachytherapy planning. This comprehensive update provides the medical physics community with more precise and in some cases more accurate Monte Carlo (MC) TG-43 dose calculation parameters, as well as fully benchmarked and described source models which are distributed with egs_brachy.


Assuntos
Braquiterapia , Braquiterapia/métodos , Dosagem Radioterapêutica , Radiometria/métodos , Física , Método de Monte Carlo , Planejamento da Radioterapia Assistida por Computador/métodos
3.
Med Phys ; 47(9): 4656-4669, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32436344

RESUMO

PURPOSE: To update the Carleton Laboratory for Radiotherapy Physics (CLRP) TG-43 dosimetry database for low-energy (≤50 keV) photon-emitting low-dose rate (LDR) brachytherapy sources utilizing the open-source EGSnrc application egs_brachy rather than the BrachyDose application used previously for 27 LDR sources in the 2008 CLRP version (CLRPv1). CLRPv2 covers 40 sources ( 103 Pd, 125 I, and 131 Cs). A comprehensive set of TG-43 parameters is calculated, including dose-rate constants, radial dose functions with functional fitting parameters, 1D and 2D anisotropy functions, along-away dose-rate tables, Primary-Scatter separation dose tables (for some sources), and mean photon energies at the surface of the sources. The database also documents the source models which will become part of the egs_brachy distribution. ACQUISITION AND VALIDATION METHODS: Datasets are calculated after a systematic recoding of the source geometries using the egs++ geometry package and its egs_brachy extensions. Air-kerma strength per history is calculated for models of NIST's Wide-Angle Free-Air chamber (WAFAC) and for a point detector located at 10 cm on the source's transverse axis. Full scatter water phantoms with varying voxel resolutions in cylindrical coordinates are used for dose calculations. New statistical uncertainties of source volume corrections for phantom voxels which overlap with brachytherapy sources are implemented in egs_brachy, and all CLRPv2 data include these uncertainties. For validation, data are compared to CLRPv1 and other data in the literature. DATA FORMAT AND ACCESS: Data are available at https://physics.carleton.ca/clrp/egs_brachy/seed_database_v2, http://doi.org/10.22215/clrp/tg43v2. As well as being presented graphically in comparisons to previous calculations, data are available in Excel (.xlsx) spreadsheets for each source. POTENTIAL APPLICATIONS: The database has applications in research, dosimetry, and brachytherapy treatment planning. This comprehensive update provides the medical physics community with more accurate TG-43 dose evaluation parameters, as well as fully benchmarked and described source models which are distributed with egs_brachy.


Assuntos
Braquiterapia , Laboratórios , Método de Monte Carlo , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
4.
J Contemp Brachytherapy ; 11(6): 563-572, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31969915

RESUMO

PURPOSE: The study compared the experimentally measured radial dose function, g(r), and anisotropy function, F(r,θ), of a BEBIG 60Co (Co0.A86) high-dose-rate (HDR) source in an in-house designed water phantom with egs_brachy Monte Carlo (MC) calculated values. MC results available in the literature were only for unbounded phantoms, and there are no currently published data in the literature for experimental data compared to MC calculations for a bounded phantom. MATERIAL AND METHODS: egs_brachy is a fast EGSnrc application designed for brachytherapy applications. For unbounded phantom calculation, we considered a cylindrical phantom with a length and diameter of 80 cm and used liquid water. These egs_brachy calculated TG43U1 parameters were compared with the consensus data. Upon its validation, we experimentally measured g(r) and F(r,θ) in a precisely machined 30 × 30 × 30 cm3 water phantom using TLD-100 and EBT2 Gafchromic Film and compared it with the egs_brachy results of the same geometry. RESULTS: The TG43U1 dosimetric dataset calculated using egs_brachy was compared with published data for an unbounded phantom, and found to be in good agreement within 2%. From our experimental results of g(r) and F(r,θ), the observed variation with the egs_brachy code calculation is found to be within the acceptable experimental uncertainties of 3%. CONCLUSIONS: In this study, we validated the egs_brachy calculation of the TG43U1 dataset for the BEBIG 60Co source for an unbounded geometry. Subsequently, we measured the g(r) and F(r,θ) for the same source using an in-house water phantom. In addition, we validated these experimental results with the values calculated using the egs_brachy MC code, with the same geometry and similar phantom material as used in the experimental methods.

5.
Phys Med Biol ; 63(3): 038002, 2018 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-29192606

RESUMO

We respond to the comments by Dr Yegin by identifying the source of an error in a fit in our original paper but arguing that the lack of a fit does not affect the conclusion based on the raw data that [Formula: see text] is an accurate code and we provide further benchmarking data to demonstrate this point.


Assuntos
Braquiterapia , Método de Monte Carlo , Benchmarking
6.
Med Phys ; 44(11): 5961-5976, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28722180

RESUMO

PURPOSE: A joint working group was created by the American Association of Physicists in Medicine (AAPM), the European Society for Radiotherapy and Oncology (ESTRO), and the Australasian Brachytherapy Group (ABG) with the charge, among others, to develop a set of well-defined test case plans and perform calculations and comparisons with model-based dose calculation algorithms (MBDCAs). Its main goal is to facilitate a smooth transition from the AAPM Task Group No. 43 (TG-43) dose calculation formalism, widely being used in clinical practice for brachytherapy, to the one proposed by Task Group No. 186 (TG-186) for MBDCAs. To do so, in this work a hypothetical, generic high-dose rate (HDR) 192 Ir shielded applicator has been designed and benchmarked. METHODS: A generic HDR 192 Ir shielded applicator was designed based on three commercially available gynecological applicators as well as a virtual cubic water phantom that can be imported into any DICOM-RT compatible treatment planning system (TPS). The absorbed dose distribution around the applicator with the TG-186 192 Ir source located at one dwell position at its center was computed using two commercial TPSs incorporating MBDCAs (Oncentra® Brachy with Advanced Collapsed-cone Engine, ACE™, and BrachyVision ACUROS™) and state-of-the-art Monte Carlo (MC) codes, including ALGEBRA, BrachyDose, egs_brachy, Geant4, MCNP6, and Penelope2008. TPS-based volumetric dose distributions for the previously reported "source centered in water" and "source displaced" test cases, and the new "source centered in applicator" test case, were analyzed here using the MCNP6 dose distribution as a reference. Volumetric dose comparisons of TPS results against results for the other MC codes were also performed. Distributions of local and global dose difference ratios are reported. RESULTS: The local dose differences among MC codes are comparable to the statistical uncertainties of the reference datasets for the "source centered in water" and "source displaced" test cases and for the clinically relevant part of the unshielded volume in the "source centered in applicator" case. Larger local differences appear in the shielded volume or at large distances. Considering clinically relevant regions, global dose differences are smaller than the local ones. The most disadvantageous case for the MBDCAs is the one including the shielded applicator. In this case, ACUROS agrees with MC within [-4.2%, +4.2%] for the majority of voxels (95%) while presenting dose differences within [-0.12%, +0.12%] of the dose at a clinically relevant reference point. For ACE, 95% of the total volume presents differences with respect to MC in the range [-1.7%, +0.4%] of the dose at the reference point. CONCLUSIONS: The combination of the generic source and generic shielded applicator, together with the previously developed test cases and reference datasets (available in the Brachytherapy Source Registry), lay a solid foundation in supporting uniform commissioning procedures and direct comparisons among treatment planning systems for HDR 192 Ir brachytherapy.


Assuntos
Algoritmos , Braquiterapia/métodos , Radioisótopos de Irídio/uso terapêutico , Método de Monte Carlo , Doses de Radiação , Humanos , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
7.
Phys Med Biol ; 61(23): 8214-8231, 2016 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-27804922

RESUMO

egs_brachy is a versatile and fast Monte Carlo (MC) code for brachytherapy applications. It is based on the EGSnrc code system, enabling simulation of photons and electrons. Complex geometries are modelled using the EGSnrc C++ class library and egs_brachy includes a library of geometry models for many brachytherapy sources, in addition to eye plaques and applicators. Several simulation efficiency enhancing features are implemented in the code. egs_brachy is benchmarked by comparing TG-43 source parameters of three source models to previously published values. 3D dose distributions calculated with egs_brachy are also compared to ones obtained with the BrachyDose code. Well-defined simulations are used to characterize the effectiveness of many efficiency improving techniques, both as an indication of the usefulness of each technique and to find optimal strategies. Efficiencies and calculation times are characterized through single source simulations and simulations of idealized and typical treatments using various efficiency improving techniques. In general, egs_brachy shows agreement within uncertainties with previously published TG-43 source parameter values. 3D dose distributions from egs_brachy and BrachyDose agree at the sub-percent level. Efficiencies vary with radionuclide and source type, number of sources, phantom media, and voxel size. The combined effects of efficiency-improving techniques in egs_brachy lead to short calculation times: simulations approximating prostate and breast permanent implant (both with (2 mm)3 voxels) and eye plaque (with (1 mm)3 voxels) treatments take between 13 and 39 s, on a single 2.5 GHz Intel Xeon E5-2680 v3 processor core, to achieve 2% average statistical uncertainty on doses within the PTV. egs_brachy will be released as free and open source software to the research community.


Assuntos
Braquiterapia/métodos , Método de Monte Carlo , Imagens de Fantasmas , Próteses e Implantes , Monitoramento de Radiação/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Algoritmos , Neoplasias da Mama/radioterapia , Neoplasias Oculares/radioterapia , Feminino , Humanos , Masculino , Neoplasias da Próstata/radioterapia , Monitoramento de Radiação/normas , Dosagem Radioterapêutica , Software