1.
J Invasive Cardiol ; 35(5): E225-E233, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36920890

RESUMO

BACKGROUND: Although first-generation drug-eluting stent (DES) devices have effectively achieved their main goal of reducing restenosis, their safety has been limited by suboptimal polymer biocompatibility, delayed stent endothelialization, and local drug toxicity, which ultimately prompted the development of new-generation DES options carrying biocompatible or even biodegradable polymers. AIMS: We sought to assess the vessel-healing pattern of the novel sirolimus-eluting Inspiron DES (Scitech Medical) using serial optical coherence tomography (OCT) and assuming the hypothesis that this thin-strut (75-µm), biodegradable-polymer DES promotes a faster healing, with very early strut coverage. METHODS: This is a prospective, multicenter, open-label, single-arm study enrolling 68 patients who underwent percutaneous coronary intervention guided by OCT. These patients were consecutively assigned into 3 groups. The first group had its OCT imaging follow-up performed at 3 months, the second group at 2 months, and the third group at 1 month. RESULTS: Mean age was 59.5 years, 70.6% were male, 41.2% had type 2 diabetes, and 29.4% presented with acute coronary syndrome. A total of 72 lesions were treated and 1.06 stents were implanted per patient. OCT assessment of the stents at 1, 2, and 3 months showed a strut coverage of 90.41%, 93.96%, and 97.21%, respectively (P=.04). CONCLUSION: The Inspiron DES showed an early strut healing pattern, with >90% of the struts covered by neointima within the first month and with almost all struts covered by the third month.


Assuntos
Doença da Artéria Coronariana , Diabetes Mellitus Tipo 2 , Stents Farmacológicos , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Doença da Artéria Coronariana/terapia , Tomografia de Coerência Óptica/métodos , Estudos Prospectivos , Resultado do Tratamento , Desenho de Prótese , Stents , Polímeros
4.
Circ Cardiovasc Interv ; 10(12)2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29246909

RESUMO

BACKGROUND: To assess the vessel-healing pattern of Ultimaster drug-eluting stent using optical frequency domain imaging. Our hypothesis is that biodegradable polymer-based drug-eluting technology allows complete very early strut coverage. METHODS AND RESULTS: The DISCOVERY 1TO3 study (Evaluation With OFDI of Strut Coverage of Terumo New Drug Eluting Stent With Biodegradable Polymer at 1, 2, and 3 Months) is a prospective, single-arm, multicenter study. A total of 60 patients with multivessel disease requiring staged procedure at 1 month were treated with Ultimaster. Optical frequency domain imaging was acquired at baseline, 1, 2, and 3 months. The primary end point is optical frequency domain imaging-assessed strut coverage at 3 months. Mean age of patients was 67.2±9.9 years, and 73.3% were male, and 36.7% presented with acute coronary syndrome. A total of 132 lesions were treated, with average 1.4 lesions per patient treated at baseline and 1.1 lesions treated at 1 month. Strut coverage at 3 months of single implanted stents (n=71, primary end point) was 95.2±5.2% and of combined single and overlapped stents was 95.4±4.9%. Strut coverage of combined single and overlapped stents at 1 (n=49) and 2 months (n=38) was 85.1±12.7% and 87.9±10.8%, respectively. The median neointimal hyperplasia thickness was 0.04, 0.05, and 0.06 mm, whereas mean neointimal hyperplasia obstruction was 4.5±2.4%, 5.2±3.4%, and 6.6±3.3% at 1, 2, and 3 months, respectively. CONCLUSIONS: Nearly complete strut coverage was observed in this complex population very early after implantation of Ultimaster drug-eluting stent. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT01844843.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/efeitos dos fármacos , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Poliésteres/química , Sirolimo/administração & dosagem , Tomografia de Coerência Óptica , Idoso , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Europa (Continente) , Feminino , Humanos , Hiperplasia , Masculino , Pessoa de Meia-Idade , Neointima , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento , Cicatrização/efeitos dos fármacos
5.
Catheter Cardiovasc Interv ; 88(S1): 38-53, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27797463

RESUMO

Fully bioresorbable scaffolds (BRS) represent a novel approach for the percutaneous treatment of coronary artery stenosis, providing temporary vessel scaffolding with drug-eluting capability during the restenosis-prone phase of the vascular healing. Beyond this initial critical period, when mechanical scaffolding support is no longer necessary, the device is bioresorbed, restoring the normal vascular physiology with the aim to eliminate the long-term safety concerns related to permanent metallic implants. Nonetheless, current BRS technology suffers from limited mechanical properties as compared to available metallic platforms, requiring careful attention to lesion preparation, accurate vessel sizing, and implantation technique. Intravascular imaging has played an important role in providing knowledge on the acute effects after BRS deployment, and it helped refine the current technique of BRS implantation. In addition, extensive work with multiple intravascular imaging modalities have also contributed to the understanding of the unique dynamic vascular changes that are experienced in the treated segment from post-implantation up to complete device bioresorption. In this manuscript, we review the role of invasive imaging modalities-from angiography to sound- and light-based techniques-to guide BRS implantation procedures, to assess its acute results postimplantation, and the changes experienced in the long-term until complete bioresorption has ensued. © 2016 Wiley Periodicals, Inc.


Assuntos
Implantes Absorvíveis , Doença da Artéria Coronariana/diagnóstico , Diagnóstico por Imagem/métodos , Stents Farmacológicos , Intervenção Coronária Percutânea/métodos , Alicerces Teciduais , Doença da Artéria Coronariana/cirurgia , Seguimentos , Humanos , Fatores de Tempo , Tomografia de Coerência Óptica
6.
JACC Cardiovasc Interv ; 6(10): 1035-45, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24156964

RESUMO

OBJECTIVES: This study sought to assess stent-vessel interactions after drug-eluting stent (DES) implantation in unprotected left main coronary artery (ULM) by frequency-domain optical coherence tomography (FD-OCT). BACKGROUND: Percutaneous coronary intervention using DES in ULM has been increasingly performed in routine practice. Recently, FD-OCT assessments of DES-vessel interactions have been used as surrogates for DES safety; however, there are no FD-OCT studies in ULM. METHODS: We prospectively enrolled 33 consecutive patients with ULM disease treated with sirolimus- (n = 11) and everolimus-eluting stents (n = 22). FD-OCT assessments were performed post-percutaneous coronary intervention and at 9-month follow-up. Three different segments of ULM were compared: distal (DIS), bifurcation (BIF), and ostial-body (BODY). The primary endpoints were percentages of uncovered and malapposed struts at 9-month follow-up, and the secondary endpoint was neointimal hyperplasia area. RESULTS: We analyzed 25,873 stent struts. Significant differences were demonstrated for percentage of uncovered struts (3.4%, 11.7%, and 18.7%, respectively for DIS, BIF, and BODY; p < 0.05 for all the comparisons). Malapposition was also more common in BODY (5.3%) than in DIS (0.6%) and BIF (2.0%) segments (p < 0.05 for BODY vs. DIS, and BODY vs. BIF). Equivalent neointimal hyperplasia areas were demonstrated in all segments. Acute malapposition rates led to different patterns of DES-vessel interactions at 9-month follow-up. CONCLUSIONS: Distinct patterns of DES-vessel interactions were demonstrated in different segments of ULM. Acute stent strut malapposition affects these findings.


Assuntos
Doença da Artéria Coronariana/terapia , Vasos Coronários/patologia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Tomografia de Coerência Óptica , Idoso , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/efeitos dos fármacos , Everolimo , Feminino , Humanos , Hiperplasia , Masculino , Pessoa de Meia-Idade , Neointima , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Sirolimo/administração & dosagem , Sirolimo/análogos & derivados , Fatores de Tempo , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 82(3): E173-83, 2013 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-23359350

RESUMO

OBJECTIVES: To investigate safety and feasibility of imaging unprotected left main (ULM) using frequency-domain optical coherence tomography (FD-OCT) compared with intravascular ultrasound (IVUS). BACKGROUND: IVUS has been used to assess and guide percutaneous coronary intervention (PCI) of ULM disease. FD-OCT offers 10-fold higher axial resolution than IVUS and its high-speed image acquisition obviates the need for proximal balloon occlusion. METHODS: We prospectively enrolled 35 consecutive patients with ULM disease. FD-OCT and IVUS assessments were attempted pre- and post-PCI and compared in regards to safety, ability to image the region of interest (ROI), number of pullbacks, volume of contrast and ability to detect malapposition, dissection, and thrombus. RESULTS: Patients were followed for 1 year when FD-OCT imaging was repeated. FD-OCT required more repeated pullbacks to image the ROI compared to IVUS. Mean lumen and stent areas were similar between FD-OCT and IVUS (11.24 ± 2.66 vs. 10.85 ± 2.47 mm(2) , P = 0.13 and 10.44 ± 2.33 vs. 10.49 ± 2.32 mm(2) , P = 0.82, respectively), whereas imaged stent length was shorter with FD-OCT. Malapposition areas and volumes were larger and more edge dissections were detected by FD-OCT. There were no clinical adverse events and no complications associated with FD-OCT at baseline and 1-year follow-up. All dissections were healed, whereas stent malapposition was still detected at follow-up. CONCLUSIONS: FD-OCT assessment of ULM is feasible and safe. Direct comparisons with IVUS reveal that FD-OCT achieved imaging completeness less often, whereas it was more sensitive in detecting malapposition and edge dissections, and similar to IVUS in the assessment of lumen and stent dimensions.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Tomografia de Coerência Óptica , Ultrassonografia de Intervenção , Idoso , Meios de Contraste , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Doença da Artéria Coronariana/terapia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/instrumentação , Projetos Piloto , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Risco , Índice de Gravidade de Doença , Stents , Fatores de Tempo , Tomografia de Coerência Óptica/efeitos adversos , Resultado do Tratamento , Ultrassonografia de Intervenção/efeitos adversos , Cicatrização
8.
Biomed Opt Express ; 3(11): 2809-24, 2012 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-23162720

RESUMO

Intravascular optical coherence tomography (iOCT) is being used to assess viability of new coronary artery stent designs. We developed a highly automated method for detecting stent struts and measuring tissue coverage. We trained a bagged decision trees classifier to classify candidate struts using features extracted from the images. With 12 best features identified by forward selection, recall (precision) were 90%-94% (85%-90%). Including struts deemed insufficiently bright for manual analysis, precision improved to 94%. Strut detection statistics approached variability of manual analysis. Differences between manual and automatic area measurements were 0.12 ± 0.20 mm(2) and 0.11 ± 0.20 mm(2) for stent and tissue areas, respectively. With proposed algorithms, analyst time per stent should significantly reduce from the 6-16 hours now required.

9.
EuroIntervention ; 8(2): 225-34, 2012 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-22717925

RESUMO

BACKGROUND: Little is known about the correlation between modifications in plaque composition at stent edges and the changes in vessel geometry. This study sought to evaluate, by serial greyscale intravascular ultrasound (IVUS) and Virtual Histology intravascular ultrasound (VH-IVUS), the modifications in plaque composition at the edges of drug-eluting and bare metal stents and the correlation of these findings with changes in the measurements of vessel, lumen and plaque area at those segments. METHODS AND RESULTS: Single-centre, prospective and randomised (1:1) evaluation of 40 patients with acute coronary syndrome treated with bare metal (Driver; Medtronic, Santa Clara, CA, USA; n=20 patients) or drug-eluting stents (Cypher; Cordis, Miami Lakes, FL, USA; n=20 patients). IVUS and VH-IVUS assessments were done post-procedure and at nine months. Primary endpoint included the modification in vessel, lumen and plaque area and in the composition of the plaque in the mean time between the baseline and follow-up procedure. At the proximal edge of the vessel treated with the Cypher stent, a trend toward positive vessel remodelling (D=+0.6 mm², p=0.06) was observed while at the distal edge, less plaque growth (D=+0.2 mm² vs. D=+1.1 mm², p<0.001), resulted in a larger lumen area at follow-up. By VH, there was a marked reduction in the percentage of fibrotic tissue and necrotic core at the edges of both stents and a positive correlation was seen between increase in percentage of fibro-fatty component and increase in plaque area (r=0.78, p=0.01). CONCLUSION: Patients treated with drug-eluting stents (DES) experienced less plaque growth, especially at the distal edge of the stents. Modifications in plaque composition, with increase in fibrofatty tissue component, may partially explain these findings.


Assuntos
Síndrome Coronariana Aguda/terapia , Angioplastia Coronária com Balão , Vasos Coronários/patologia , Stents Farmacológicos , Placa Aterosclerótica/prevenção & controle , Stents , Ultrassonografia de Intervenção , Síndrome Coronariana Aguda/diagnóstico por imagem , Idoso , Angiografia Coronária , Feminino , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA