Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Am J Emerg Med ; 37(8): 1446-1449, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31378298

RESUMO

BACKGROUND: Emergency medical services (EMSs) are used by approximately 383,000 patients with out-of-hospital sudden cardiac arrest (SCA) in the United States. Hence, it is crucial to implement automated external defibrillator (AED) programs to prepare responders for an SCA emergency. Taiwanese pass legislature to enforce AED installation in 8 mandatory areas since 2013. Our study investigated the efficacy of the policy regarding AED installation. MATERIALS AND METHODS: We collected data of patients who had sudden cardiac arrest (SCA) in pre-hospital settings, and received resuscitative efforts, including cardiopulmonary resuscitation or defibrillation with AEDs. The data were from July 11, 2013 to July 31, 2015. In total, 209 adult patients were documented by on-site caregivers of different facilities, and a report was mailed to the central health and welfare unit. RESULTS: Schools, large-scale gathering places, and special institutions used AEDs the most, accounting for 33 (15.3%) cases. From non-mandatory AED areas, long-term care facilities had the maximum cases of AED use (32 cases; 14.9%). With commuting stations as a reference, long-distance transport had the lowest odds ratio (OR) of 0.481 (95% confidence interval [CI], 0.24-0.962). The OR for schools, large-scale gathering places, and special institutions was 4.474 (95% CI: 2.497-8.015). Regarding failure of return of spontaneous circulation (ROSC), the OR for the ≥80-year age group was higher than that for the 20-39-year age group. CONCLUSIONS: The policy regarding the legislation to install AEDs in mandatory areas improved AED accessibility. Elderly patients aged ≥80 years have a higher rate of ROSC failure.


Assuntos
Fatores Etários , Desfibriladores/estatística & dados numéricos , Serviços Médicos de Emergência/estatística & dados numéricos , Utilização de Equipamentos e Suprimentos/estatística & dados numéricos , Acessibilidade aos Serviços de Saúde/organização & administração , Parada Cardíaca Extra-Hospitalar/mortalidade , Adulto , Idoso , Reanimação Cardiopulmonar/métodos , Serviços Médicos de Emergência/legislação & jurisprudência , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Taiwan/epidemiologia
2.
PLoS One ; 13(6): e0198852, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29902218

RESUMO

Atrial fibrillation (AF) is the most common arrhythmia. The most common diagnostic method, 12-lead electrocardiogram (ECG), can record episodes of arrhythmia from which the type and severity can be determined. The Heart Spectrum Blood Pressure Monitor (P2; OSTAR Meditech Corp., New Taipei City, Taiwan) is used to measure cardiovascular pressure change with fast Fourier transform (FFT) analysis to obtain heart rate frequency variability and accurate blood pressure data. We compared the diagnostic efficacy of the Heart Spectrum Blood Pressure Monitor to a 12-lead ECG (gold standard) for patients with AF. Three measurement methods were used in this study to analyze the heart index and compare the results with simultaneous 12-lead ECG: blood pressure; mean arterial pressure, which was calculated from individual blood pressure as a constant pressure; and a constant pressure of 60 mmHg. The physician used a 12-lead ECG and the Heart Spectrum Blood Pressure Monitor simultaneously. The Heart Spectrum Blood Pressure Monitor used FFT analysis to diagnose AF, and the findings were compared to the 12-lead ECG readings. This unblinded clinical trial was conducted in the emergency department of Taipei Medical University Hospital. Twenty-nine subjects with AF and 33 without AF aged 25 to 97 y (mean, 63.5 y) were included. Subjects who were exposed to high-frequency surgical equipment during testing, those with cardiac pacemakers or implantable defibrillators, and pregnant women were excluded. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were 97%, 97%, 97%, and 97%, respectively, for method 1; 90%, 100%, 100%, and 91%, respectively, for method 2; and 100%, 94%, 94%, and 100%, respectively, for method 3. The sensitivity, specificity, PPV, and NPV for both methods ranged between 90% and 100%, indicating that the Heart Spectrum Blood Pressure Monitor can be effectively applied for AF detection.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Monitores de Pressão Arterial , Coração/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA