Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Radiology ; 305(2): 329-338, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35880980

RESUMO

Background The relationship between papillary muscle infarction (papMI) and the culprit coronary lesion has not been fully investigated. Delayed enhancement cardiac MRI may detect papMI, yet its accuracy is unknown. Flow-independent dark-blood delayed enhancement (FIDDLE) cardiac MRI has been shown to improve the detection of myocardial infarction adjacent to blood pool. Purpose To assess the diagnostic performance of delayed enhancement and FIDDLE cardiac MRI for the detection of papMI, and to investigate the prevalence of papMI and its relationship to the location of the culprit coronary lesion. Materials and Methods A prospective canine study was used to determine the accuracy of conventional delayed enhancement imaging and FIDDLE imaging for detection of papMI, with pathology-based findings as the reference standard. Participants with first-time myocardial infarction with a clear culprit lesion at coronary angiography were prospectively enrolled at a single hospital from 2015 to 2018 and compared against control participants with low Framingham risk scores. In canines, diagnostic accuracy was calculated for delayed enhancement and FIDDLE imaging. Results In canines (n = 27), FIDDLE imaging was more sensitive (100% [23 of 23] vs 57% [13 of 23], P < .001) and accurate (100% [54 of 54] vs 80% [43 of 54], P = .01) than delayed enhancement imaging for detection of papMI. In 43 participants with myocardial infarction (mean age, 56 years ± 16 [SD]; 28 men), the infarct-related artery was the left anterior descending coronary artery (LAD), left circumflex coronary artery (LCX), and right coronary artery in 47% (20 of 43), 26% (11 of 43), and 28% (12 of 43), respectively. The prevalence of anterior papMI was lower than posterior papMI (37% [16 of 43 participants] vs 44% [19 of 43 participants]) despite more LAD culprit lesions. Culprits leading to papMI were restricted to a smaller "at-risk" portion of the coronary tree for anterior papMI (subtended first diagonal branch of the LAD or first marginal branch of the LCX) compared with posterior (subtended posterior descending artery or third obtuse marginal branch of the LCX). Culprits within these at-risk portions were predictive of papMI at a similar rate (anterior, 83% [15 of 18 participants] vs posterior, 86% [18 of 21 participants]). Conclusion Flow-independent dark-blood delayed enhancement cardiac MRI, unlike conventional delayed enhancement cardiac MRI, was highly accurate in the detection of papillary muscle infarction (papMI). Anterior papMI was less prevalent than posterior papMI, most likely due to culprit lesions being restricted to a smaller portion of the coronary tree rather than because of redundant, dual vascular supply. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Kawel-Boehm and Bremerich in this issue.


Assuntos
Infarto do Miocárdio , Músculos Papilares , Masculino , Humanos , Cães , Animais , Pessoa de Meia-Idade , Músculos Papilares/diagnóstico por imagem , Músculos Papilares/patologia , Estudos Prospectivos , Infarto do Miocárdio/diagnóstico por imagem , Vasos Coronários/patologia , Angiografia Coronária/efeitos adversos , Infarto , Imageamento por Ressonância Magnética/efeitos adversos
2.
NMR Biomed ; 35(10): e4777, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35633068

RESUMO

Myocardial lipomatous metaplasia, which can serve as substrate for ventricular arrhythmias, is usually composed of regions in which there is an admixture of fat and nonfat tissue. Although dedicated sequences for the detection of fat are available, it would be time-consuming and burdensome to routinely use these techniques to image the entire heart of all patients as part of a typical cardiac MRI exam. Conventional steady-state free-precession (SSFP) cine imaging is insensitive to detecting myocardial regions with partial fatty infiltration. We developed an optimization process for SSFP imaging to set fat signal consistently "out-of-phase" with water throughout the heart, so that intramyocardial regions with partial volume fat would be detected as paradoxically dark regions. The optimized SSFP sequence was evaluated using a fat phantom, through simulations, and in 50 consecutive patients undergoing clinical cardiac MRI. Findings were validated using standard Dixon gradient-recalled-echo (GRE) imaging as the reference. Phantom studies of test tubes with diverse fat concentrations demonstrated good agreement between measured signal intensity and simulated values calculated using Bloch equations. In patients, a line of signal cancellation at the interface between myocardium and epicardial fat was noted in all cases, confirming that SSFP images were consistently out-of-phase throughout the entire heart. Intramyocardial dark regions identified on out-of-phase SSFP images were entirely dark throughout in 33 patients (66%) and displayed an India-ink pattern in 17 (34%). In all cases, dark intramyocardial regions were also seen in the same locations on out-of-phase GRE and were absent on in-phase GRE, confirming that these regions represent areas with partial fat. In conclusion, if appropriately optimized, SSFP cine imaging allows for consistent detection of myocardial fatty metaplasia in patients undergoing routine clinical cardiac MRI without the need for additional image acquisitions using dedicated fat-specific sequences.


Assuntos
Imageamento por Ressonância Magnética , Miocárdio , Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética/métodos , Metaplasia , Imagens de Fantasmas
3.
Circulation ; 111(8): 1033-9, 2005 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-15723978

RESUMO

BACKGROUND: Magnetic resonance global coherent free precession (GCFP) is a new technique that produces cine projection angiograms directly analogous to those of x-ray angiography noninvasively and without a contrast agent. In this study, we compared GCFP blood flow with "gold standards" to determine the accuracy of noninvasive GCFP blood flow measurements. METHODS AND RESULTS: The relationship between GCFP blood flow and true blood flow defined by invasive ultrasonic flow probe and by phase contrast velocity encoded MRI (VENC) was studied in anesthetized dogs (n=6). Blood flow was controlled by use of a hydraulic occluder around the left iliac artery. GCFP images were acquired by selectively exciting the abdominal aorta and visualizing temporal blood flow into the iliac arteries. GCFP flow was similar to ultrasonic blood flow at baseline (131.3+/-44.8 versus 114.8+/-34.2 mL/min), during occlusion (10.8+/-5.1 versus 6.5+/-7.2 mL/min), during reactive hyperemia (191.4+/-100.7 versus 260.3+/-138.7 mL/min), during the new resting state (135.5+/-52.4 versus 117.8+/-24.1 mL/min), and during partial occlusion (61.4+/-36.4 versus 49.3+/-13.1 mL/min, P=NS for all). Results comparing GCFP flow with VENC were similar. Statistical analysis revealed that GCFP flow was related to mean blood flow assessed by the flow probe (P<0.0001) and by VENC (P<0.0001). In the control right iliac artery, conversely, GCFP measurements were unaffected throughout all left iliac interventions (P=NS). CONCLUSIONS: GCFP blood flow is linearly related to true blood flow for a straight, cylindrical blood vessel without branches. Although more complex geometries imply a qualitative rather than a quantitative relationship, the data nevertheless suggest that GCFP may serve as the basis for a new form of noninvasive stress testing.


Assuntos
Imagem Cinética por Ressonância Magnética/tendências , Fluxo Sanguíneo Regional/fisiologia , Animais , Cães , Imagem Cinética por Ressonância Magnética/métodos , Técnicas de Sonda Molecular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA