Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Interv Cardiol ; 2021: 2629393, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34113221

RESUMO

OBJECTIVES: To assess the impact of different guidewires on stent coating integrity in jailed wire technique (JWT) for bifurcation treatment. BACKGROUND: JWT is commonly adopted to protect side branch in provisional one-stent strategy for coronary bifurcation lesions. However, this technique may cause defects in stent coatings. The degree of coating damage caused by different types of jailed wires remains unknown. METHODS: A fluid model with a bifurcation was established to mimic the condition in vivo. One-stent strategy was performed with three types of guidewire (nonpolymer-jacketed wire, intermediate polymer-jacketed wire, and full polymer-jacketed wire) tested for JWT. Scanning electron microscopy (SEM) was used to evaluate stent coating integrity and wire structure. The degrees of coating defects were recorded as no, slight, moderate, and severe defects. RESULTS: A total of 27 samples were tested. Analyses of SEM images showed a significant difference in the degree of coating damage among the three types of wire after the procedure of JWT (P < 0.001). Nonpolymer-jacketed wire could inevitably cause a severe defect in stent coatings, while full polymer-jacketed wire caused the least coating damages. Besides, there were varying degrees of coil deformation in nonpolymer-jacketed wires, while no surface damage or jacket shearing was observed in full polymer-jacketed wires. CONCLUSIONS: Although nonpolymer-jacketed wire has long been recommended for JWT, our bench-side study suggests that full polymer-jacketed wire may be a better choice. Further clinical studies are needed to confirm our findings.


Assuntos
Intervenção Coronária Percutânea/instrumentação , Ajuste de Prótese , Stents/efeitos adversos , Materiais Revestidos Biocompatíveis/farmacologia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/cirurgia , Falha de Equipamento , Humanos , Teste de Materiais/métodos , Microscopia Eletrônica de Varredura/métodos , Modelos Anatômicos , Intervenção Coronária Percutânea/métodos , Polímeros/farmacologia , Desenho de Prótese , Ajuste de Prótese/efeitos adversos , Ajuste de Prótese/métodos
2.
Catheter Cardiovasc Interv ; 95 Suppl 1: 550-557, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31922352

RESUMO

OBJECTIVES: To assess the predictive value of the Global Registry of Acute Coronary Events (GRACE) discharge score for patients with stable coronary artery disease (SCAD) after percutaneous coronary intervention (PCI). BACKGROUND: The GRACE score is widely used for predicting the mortality of acute coronary syndrome patients. However, the predictive value of SCAD has not been sufficiently studied. METHODS: We studied 4,293 consecutive patients with SCAD who underwent PCI between January 2013 and December 2013. The primary endpoint was all-cause mortality and the secondary endpoint was major adverse cardiovascular and cerebrovascular events (MACCE). RESULTS: Among 3,915 patients with SCAD following PCI, there were 38 deaths and 394 MACCE during 2 years of follow-up. The GRACE discharge score was significantly higher for patients who died than for those who survived (86.97 ± 23.27 vs. 71.07 ± 19.84; p < .001). Risk stratification of the GRACE score indicated that the mortality risk of the intermediate-risk and high-risk groups were 3.23-fold (hazard ratio [HR], 3.23; range, 1.59-6.55; p = .001) and 15.31-fold higher (HR, 15.31; range, 4.43-51.62; p < .001), respectively, than that of the low-risk group. The MACCE risk for the intermediate-risk and high-risk groups were 1.28-fold (HR, 1.28; range, 1.02-1.62; p = .037) and 2.42-fold higher (HR, 2.42; range, 1.20-4.88; p = .014), respectively. The GRACE discharge score had prognostic value for mortality (area under the receiver operating characteristic curve, 0.692; p < .001). CONCLUSIONS: The GRACE discharge score is valuable for the risk stratification of death and MACCE, as well as for the prognosis to mortality for SCAD patients who have undergone PCI.


Assuntos
Doença da Artéria Coronariana/terapia , Técnicas de Apoio para a Decisão , Indicadores Básicos de Saúde , Alta do Paciente , Intervenção Coronária Percutânea/mortalidade , Idoso , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
3.
Circ Res ; 124(4): 491-497, 2019 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-31031412

RESUMO

As we commemorate the 70th Anniversary of the National Heart, Lung, and Blood Institute (NHLBI) and celebrate important milestones that have been achieved by the Division of Cardiovascular Sciences (DCVS), it is imperative that DCVS and the Extramural Research community at-large continue to address critical public health challenges that persist within the area of Cardiovascular Diseases (CVD). The NHLBI's Strategic Vision, developed with extensive input from the extramural research community and published in 2016, included overarching goals and strategic objectives that serve to provide a general blueprint for sustaining the legacy of the Institute by leveraging opportunities in emerging scientific areas (e.g., regenerative medicine, omics technology, data science, precision medicine, and mobile health), finding new ways to address enduring challenges (e.g., social determinants of health, health inequities, prevention, and health promotion), and training the next generation of heart, lung, blood, and sleep researchers. DCVS has developed a strategic vision implementation plan to provide a cardiovascular framing for the pursuit of the Institute's overarching goals and strategic objectives garnered from the input of the broader NHLBI community. This plan highlights six scientific focus areas that demonstrate a cross-cutting and multifaceted approach to addressing cardiovascular sciences, including 1) addressing social determinants of cardiovascular health (CVH) and health inequities, 2) enhancing resilience, 3) promoting CVH and preventing CVD Across the lifespan, 4) eliminating hypertension-related CVD, 5) reducing the burden of heart failure, and 6) preventing vascular dementia. These priorities will guide our efforts in Institute-driven activities in the coming years but will not exclude development of other novel ideas or the support of investigator-initiated grant awards. The DCVS Strategic Vision implementation plan is a living document that will evolve with iterative dialogue with the NHLBI community and adapt as the dynamic scientific landscape changes to seize emerging opportunities.


Assuntos
Cardiologia/normas , Doenças Cardiovasculares/terapia , National Heart, Lung, and Blood Institute (U.S.) , Guias de Prática Clínica como Assunto , Cardiologia/economia , Cardiologia/tendências , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/etiologia , Humanos , Estados Unidos
4.
EuroIntervention ; 10(7): 806-14, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25033105

RESUMO

AIMS: To compare stent strut coverage using optical coherence tomography (OCT) at three-month follow-up between a PLGA-polymer with electro-grafting base layer sirolimus-eluting stent (SES) (BuMA) and a PLA-polymer SES (EXCEL). METHODS AND RESULTS: This prospective, single-centre, non-inferiority randomised BuMA-OCT trial enrolled patients with de novo coronary artery lesions, treated with either the BuMA or the EXCEL stent. The study primary endpoint was OCT-evaluated stent strut coverage at three months. Secondary endpoints were neointimal thickness of stent struts, and incomplete stent apposition evaluated with OCT. A total of 80 patients were randomly assigned to receive the BuMA (n=40) or the EXCEL (n=40) stent. In OCT follow-up (achieved in 86.3% of cases: BuMA, n=33; EXCEL, n=36), the percentage of stent strut coverage was significantly higher in the BuMA vs. the EXCEL group (strut level: 94.2% vs. 90.0%, p<0.01; p(non-inferiority)<0.0001; p(superiority) <0.0001), while the proportion of malapposed struts (strut level: 1.28% vs. 1.80%, p=0.51) and the mean neointimal thickness (strut level: 0.07±0.03 mm vs. 0.06±0.02 mm, p=0.31) were similar. Rates of myocardial infarction (periprocedural non-Q-wave, 7.5% vs. 7.5%, p=1.00) and target lesion failure (7.5% vs. 7.5%, p=1.00) were similar between groups, with no cardiac death or stent thrombosis. CONCLUSIONS: In the BuMA-OCT randomised trial, the novel BuMA PLGA-polymer with electro-grafting base layer SES was superior to the EXCEL PLA-polymer SES in the primary endpoint of stent strut coverage at three-month follow-up.


Assuntos
Stents Farmacológicos , Ácido Láctico/administração & dosagem , Ácido Poliglicólico/administração & dosagem , Sirolimo/administração & dosagem , Tomografia de Coerência Óptica/métodos , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea , Poliésteres/administração & dosagem , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA