Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
2.
Front Pediatr ; 11: 1159342, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37138576

RESUMO

Patients with single left ventricle (SLV) and tricuspid atresia (TA) have impaired systolic and diastolic function. However, there are few comparative studies among patients with SLV, TA and children without heart disease. The current study includes 15 children in each group. The parameters measured by two-dimensional echocardiography, three-dimensional speckle tracking echocardiography (3DSTE), and vortexes calculated by computational fluid dynamics were compared among these three groups. Twist is best correlated with ejection fraction measured by 3DSTE. Twist, torsion, apical rotation, average radial strain, peak velocity of systolic wave in left lateral wall by tissue Doppler imaging (sL), and myocardial performance index are better in the TA group than those in the SLV group. sL by tissue Doppler imaging in the TA group are even higher than those in the Control group. In patients with SLV, blood flow spreads out in a fan-shaped manner and forms two small vortices. In the TA group, the main vortex is similar to the one in a normal LV chamber, but smaller. The vortex rings during diastolic phase are incomplete in the SLV and TA groups. In summary, patients with SLV or TA have impaired systolic and diastolic function. Patients with SLV had poorer cardiac function than those with TA due to less compensation and more disordered streamline. Twist may be good indicator for LV function.

3.
Food Sci Nutr ; 8(10): 5738-5747, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33133575

RESUMO

Phthalate acid esters (PAEs) are one of the essential plastic additives which may lead to plenty of harmful effects, including reproductive toxicity, teratogenicity, and carcinogenicity. Increasing attention has been paid to the migration of plasticizer. In this article, the disposable plastic lunch boxes were taken as the research object. The result showed that dibutyl phthalate (DBP) and diisobutyl phthalate (DIBP) have been mainly found, whose content was 1.5 mg/kg and 2.4 mg/kg, respectively. The LOD was 2 ng/g, and LOQ was 6.7 ng/g. We further investigated the migration of PAEs into the simulated liquid at different temperature conditions. Then, the linear fitting performing by first-order kinetic migration model revealed that the lower the polarity of the simulated liquid, the larger the rate constant K 1 and initial release rate V 0. The higher the temperature, the bigger the K 1 and V 0.

4.
Curr Med Res Opin ; 35(2): 203-210, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-29611724

RESUMO

OBJECTIVE: Ventricular function assessment is very important for the treatment and prognostic classification of children with a single right ventricle (SRV) after cavopulmonary anastomosis (CPA). However, unusual ventricular shapes can result in inaccurate measurements. The aim of this study was to evaluate velocity vector imaging (VVI) for assessing segmental ventricular function in children with SRV after CPA. METHODS: Twenty-one children with SRV after CPA and 21 age- and sex-matched children with normal biventricular anatomy and function were included. The longitudinal velocity, displacement, strain and strain rate were measured in the two groups in six segments by VVI. The velocity, displacement, strain and strain rate of the SRVs were compared with max(dp/dt) measured during simultaneous cardiac catheterization in the SRV subjects. RESULTS: The control group consisted of 13 males and 8 females (69% males) with a mean age of 6.7 ± 3.5 years and mean weight of 20.5 ± 6.5 kg, and the study group consisted of 13 males and 8 females with a mean age 6.7 ± 3.7 years and mean weight of 20.6 ± 6.8 kg. Age, weight and sex distribution were similar between the groups (all, p > .05). Strain and strain rate values in all six segments were significantly lower in the study group than in the control group (all, p < .05). The max(dp/dt) of the SRV was 522.84 ± 158.32 mmHg/s, and the strain rate of the basal segment at the rudimentary chamber correlated best with max(dp/dt) (r = 0.74, p < .01). CONCLUSIONS: Segmental ventricular dysfunction was present in children with SRV after CPA, and it could be assessed using VVI.


Assuntos
Derivação Cardíaca Direita/métodos , Ventrículos do Coração/diagnóstico por imagem , Função Ventricular/fisiologia , Cateterismo Cardíaco/métodos , Estudos de Casos e Controles , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Prognóstico
5.
Echocardiography ; 36(1): 133-141, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30515879

RESUMO

BACKGROUND: Challenges remain in quantitative evaluation of right ventricular (RV) function by echocardiography. Multiple-view assessment is believed to provide a more comprehensive quantification of RV function than conventional single-view analysis. Peak systolic longitudinal RV strain (RVLS) measured by speckle tracking echocardiography (STE) has clinical and prognostic value. No study has investigated RV systolic function in the repaired tetralogy of Fallot (rTOF) using a standardized four-view iRotate model from one apical view. Herein, we examined the feasibility and accuracy of the four-view analysis from apical window in quantitation of RVLS among children with rTOF. METHODS: Thirty-seven children with rTOF and 37 age- and gender-matched controls were prospectively enrolled. Tricuspid annular plane systolic excursion (TAPSE) and tricuspid annular peak systolic velocity (TDI-S' ) and fractional area change(FAC) were obtained. RVLS of four free-walls were analyzed by dedicated RV speckle tracking software. Echocardiographic parameters were compared with the right ventricular ejection fraction (RVEF) measured by the cardiac magnetic resonance (CMR) in children with rTOF. RESULTS: Multi-view RVLS analysis from apical window was feasible in 35 children with rTOF and all the controls. Compared with age- and gender-matched controls, RVLS of the anterior, lateral, inferior-a, and inferior-b walls were significantly reduced in children with rTOF (P < 0.001). RVLS of the anterior, lateral, inferior-a, and inferior-b walls correlated well with CMR-RVEF in children with rTOF (r = -0.667, -0.743, -0.808, -0.695, P < 0.001). CONCLUSIONS: Multi-view analysis of RVLS from apical window can be applied to evaluate the RV function in children with rTOF. RVLS of the inferior wall-a in the aortic view is a novel and accurate indicator of RV function because of its good reproducibility and strong correlation with CMR-RVEF.


Assuntos
Ecocardiografia/métodos , Complicações Pós-Operatórias/diagnóstico por imagem , Tetralogia de Fallot/cirurgia , Disfunção Ventricular Direita/diagnóstico por imagem , Pré-Escolar , Estudos de Viabilidade , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Lactente , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes , Disfunção Ventricular Direita/fisiopatologia , Função Ventricular Direita/fisiologia
6.
Pediatr Cardiol ; 35(7): 1147-54, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24771060

RESUMO

Assessment of ventricular dysfunction and asynchrony is very important in predicting the outcome for children with a single right ventricle. However, the assessment is inaccurate and subjective because of the unusual ventricular shape. This study aimed to evaluate the feasibility and clinical value of velocity vector imaging for assessing longitudinal systolic ventricular dysfunction and intraventricular asynchrony in children with a single right ventricle. The study enrolled 36 children with a single right ventricle and 36 age-matched children with a normal heart. Peak systolic velocity, peak displacement, strain, strain rate, time to peak systolic velocity, and time to peak systolic strain were measured via velocity vector imaging using the Siemens Sequoia C512 echocardiography instrument. The maximum positive rate of ventricular pressure change (Max [dp/dt]) was obtained by cardiac catheterization for all the children with a single right ventricle. In the children with a single right ventricle, the maximal temporal differences and the standard deviations of the times to peak systolic velocity and peak systolic strain were higher (P < 0.01) than in the children with a normal heart. Moreover, the strain and strain rate values were significantly lower in all six segments (P < 0.05). The strain rate of the basal segment adjacent to the rudimentary chamber correlated best with Max (dp/dt) (r = 0.86; P < 0.01). Longitudinal systolic dysfunction and intraventricular asynchrony could be assessed accurately using velocity vector imaging in children with a single right ventricle.


Assuntos
Cateterismo Cardíaco/métodos , Ecocardiografia/métodos , Eletrocardiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Disfunção Ventricular Direita/diagnóstico , Função Ventricular Direita/fisiologia , Adolescente , Criança , Pré-Escolar , Diagnóstico por Imagem , Feminino , Seguimentos , Ventrículos do Coração/anormalidades , Ventrículos do Coração/fisiopatologia , Humanos , Lactente , Recém-Nascido , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sístole , Disfunção Ventricular Direita/congênito , Disfunção Ventricular Direita/fisiopatologia , Pressão Ventricular
7.
Chin J Integr Med ; 11(4): 272-8, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16417777

RESUMO

OBJECTIVE: To observe the tested results of the segmental range of motion (ROM) of lumbar spine by charge couple device (CCD)-based system for 3-dimensional real-time positioning (CCD system), and to analyze its clinical significance. METHODS: Seven patients with lumbar joint dysfunction and 8 healthy subjects were tested twice by the CCD-based system with an interval of 10 min. RESULTS: The ROM of the patients was obviously lesser than that of the healthy subjects. The measuring data of segmental ROM of lumbar spine by CCD system is correlated significantly to the same data checked later on the same subjects in every direction of the movements. The differences between two checks are usually less than 1 degree. CONCLUSION: Specially designed CCD based system for 3-dimensional real-time positioning could objectively reflect the segmental ROM of lumbar spine. The system would be of great clinical significance in the assessment of the biomechanical dysfunction of lumbar spine and the effect of the treatment applied.


Assuntos
Vértebras Lombares/fisiologia , Equipamentos Ortopédicos , Amplitude de Movimento Articular/fisiologia , Sistemas Computacionais , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA