Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
JACC Cardiovasc Interv ; 13(14): 1639-1650, 2020 07 27.
Artigo em Inglês | MEDLINE | ID: mdl-32703590

RESUMO

OBJECTIVES: The aim of this study was to develop a risk model incorporating clinical, angiographic, and physiological parameters to predict future clinical events after drug-eluting stent implantation. BACKGROUND: Prognostic factors after coronary stenting have not been comprehensively investigated. METHODS: A risk model to predict target vessel failure (TVF) at 2 years was developed from 2,200 patients who underwent second-generation drug-eluting stent implantation and post-stent fractional flow reserve (FFR) measurement. TVF was defined as a composite of cardiac death, target vessel myocardial infarction, and clinically driven target vessel revascularization. A random survival forest model with automatic feature selection by minimal depth analysis was used for risk model development. RESULTS: During 2 years of follow-up, the cumulative incidence of TVF was 5.9%. From clinical, angiographic, and physiological parameters, 6 variables were selected for the risk model in order of importance within the model as follows: total stent length, post-stent FFR, age, post-stent percentage diameter stenosis, reference vessel diameter, and diabetes mellitus. Harrell's C index of the random survival forest model was 0.72 (95% confidence interval [CI]: 0.62 to 0.82). This risk model showed better prediction ability than models with clinical risk factors alone (Harrell's C index = 0.55; 95% CI: 0.41 to 0.59; p for comparison = 0.005) and with clinical risk factors and angiographic parameters (Harrell's C index = 0.65; 95% CI: 0.52 to 0.77; p for comparison = 0.045). When the patients were divided into 2 groups according to the median of total stent length (30 mm), post-stent FFR and total stent length showed the highest variable importance in the short- and long-stent groups, respectively. CONCLUSIONS: A risk model incorporating clinical, angiographic, and physiological predictors can help predict the risk for TVF at 2 years after coronary stenting. Total stent length and post-stent FFR were the most important predictors. (International Post PCI FFR Registry; NCT04012281).


Assuntos
Cateterismo Cardíaco , Angiografia Coronária , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea/instrumentação , Idoso , China , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/fisiopatologia , Feminino , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Sistema de Registros , República da Coreia , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
2.
Medicine (Baltimore) ; 96(1): e5740, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28072714

RESUMO

The DEFINITION (Impact of the complexity of bifurcation lesions treated with drug-eluting stents) study has provided a novel classification to evaluate the complexity of coronary bifurcation lesion according to coronary angiography, but angiographic imaging due to its low resolution and inherited limitation may result in an inaccurate adjudication.We used optical coherence tomography (OCT) to further evaluate the coronary characteristics in a patient with "simple" bifurcation lesion which was classified by the DEFINITION criteria. However, a "complex" bifurcation lesion was defined and confirmed according to the OCT results.A double kissing Crush stenting approach was adopted to treat this "complex" case finally. The immediate and long-term angiographic and OCT results were excellent.OCT may be useful imaging modality to classify complexity of coronary bifurcation lesion and subsequently guide its treatment strategy.


Assuntos
Vasos Coronários/diagnóstico por imagem , Trombose/diagnóstico por imagem , Tomografia de Coerência Óptica , Angioplastia Coronária com Balão/métodos , Angiografia Coronária , Stents Farmacológicos , Humanos , Masculino , Pessoa de Meia-Idade , Trombose/terapia
3.
Chin Med J (Engl) ; 126(6): 1081-5, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23506582

RESUMO

BACKGROUND: Sirolimus-eluting stents (SES) are reported to be associated with reduced late lumen loss (LLL), resulting in less frequent restenosis when compared to bare-metal stent. The current study aimed to assess the difference in LLL between SES with biodegradable and with permanent polymer. METHODS: From March 2010 to June 2011, 300 consecutive patients having only biodegradable polymers or permanent polymer SES for all diseased vessels were included. Serial quantitative coronary analysis was performed on both the "in-stent" and "segment" area, including the stented segment, as well as both five mm margins proximal and distal to the stent. The primary endpoint was the LLL defined as the minimal lumen diameter (MLD) post-stenting minus the MLD at nine-month after the indexed procedure. RESULTS: LLL was comparable between the two stents. Importantly, LLL for the distal segment (median 0.05 mm, interquartile 0 to 0.09 mm) was less severe compared with in-stent (median 0.13 mm, interquartile 0.08 to 0.18 mm) and proximal segment LLL (median 0.12 mm, interquartile 0.06 to 0.14 mm, all P < 0.001). In general, the LLL was associated with the post-procedure MLD (b = 0.28, P = 0.002), hyperlipidemia (b = 0.14, P = 0.021), and calcified lesions (b = 0.58, P = 0.001). The R(2) and Radj of the multiple regression model were 0.651 and 0.625, respectively. CONCLUSIONS: SES with either biodegradable or permanent polymer had lower value of LLL. The small amount of LLL at the distal segment possibly contributed to the less distal edge stenosis.


Assuntos
Stents Farmacológicos , Polímeros/química , Sirolimo/uso terapêutico , Idoso , Aspirina/uso terapêutico , Clopidogrel , Reestenose Coronária/prevenção & controle , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise de Regressão , Ticlopidina/análogos & derivados , Ticlopidina/uso terapêutico
4.
JACC Cardiovasc Interv ; 3(6): 632-41, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20630456

RESUMO

OBJECTIVES: This study aimed to compare the NERS (New Risk Stratification) and SYNTAX (Synergy between Percutaneous Coronary Intervention with Taxus and Cardiac Surgery) scores for prognostication after stenting of unprotected left main stenosis in a "real-world" setting. BACKGROUND: In contrast to existing systems, the NERS score encompasses clinical, procedural, and angiographic characteristics. METHODS: The NERS score was derived from 260 patients with unprotected left main stenosis who underwent percutaneous coronary intervention and tested in 337 patients in a consecutive left main registry (66.55 +/- 10.49 years, 78.9% men) undergoing percutaneous coronary intervention in a prospective, multicenter trial. Six-month clinical and angiographic follow-up was obtained in 100% and 88.9% of patients, respectively. The primary end point was major adverse cardiac events (MACE), encompassing myocardial infarction, all-cause death, and target vessel revascularization. Receiver-operator characteristic (ROC) curve was generated for the comparison of NERS versus SYNTAX scores. RESULTS: The NERS score consisted of 54 variables (17 clinical, 4 procedural, and 33 angiographic). A NERS score > or =25 demonstrated a sensitivity and specificity of 92.0% and 74.1% (MACE as state variable), respectively, significantly higher than SYNTAX intermediate risk (20.5% and 25.4%) or SYNTAX higher risk (70.5% and 35.2%, p for all <0.001). At follow-up, myocardial infarction, cardiac death, and target vessel revascularization occurred in 3.0%, 5.6%, and 13.1% of patients, respectively, for a composite MACE of 26.0%. A NERS score > or =25 (hazard ratio: 1.13; 95% confidence interval [CI]: 1.11 to 1.16; p < 0.001) was the only independent predictor of cumulative MACE and stent thrombosis at follow-up (odds ratio: 31.04; 95% CI: 19.36 to 67.07; p < 0.001). CONCLUSIONS: The NERS score was more predictive of MACE than the SYNTAX score was. Further study is needed to address their relative roles in assessment for appropriateness of coronary artery bypass graft versus percutaneous coronary intervention for unprotected left main coronary artery stenosis.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Ponte de Artéria Coronária , Estenose Coronária/terapia , Stents Farmacológicos , Indicadores Básicos de Saúde , Paclitaxel/administração & dosagem , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Distribuição de Qui-Quadrado , China , Angiografia Coronária , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/mortalidade , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/mortalidade , Estenose Coronária/cirurgia , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Razão de Chances , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Estudos Prospectivos , Desenho de Prótese , Curva ROC , Sistema de Registros , Medição de Risco , Fatores de Risco , Trombose/etiologia , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA