Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Med Syst ; 35(5): 877-83, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20703683

RESUMO

In Taiwan, the number of the patients needing dialysis increases rapidly in recent years. Because there is risk in every hemodialysis session, monitoring physiological status, such as blood pressure measurement every 30 min to 1 h is needed during about 4 h hemodialysis process. Therefore, an assisted measurement on blood pressure is needful in dialysis care centers. Telecare system (TCS) is regarded as one of important technique in the medical care. In this study, we utilized ZigBee wireless technique to establish a mesh network for monitoring blood pressure automatically and data storage in medical record system for display and further analysis. Moreover, while the blood pressure exceeds the normal range, the system could send a warning signal to remind, or inform the relatives and clinicians in health care center through the personal handy-phone system (PHS) immediately. The proposed system provides an assisted device for monitoring patients' blood pressure during hemodialysis process and saving medical manpower.


Assuntos
Monitorização Ambulatorial da Pressão Arterial/métodos , Centros Comunitários de Saúde , Diálise Renal , Telemetria/instrumentação , Redes de Comunicação de Computadores , Humanos , Taiwan
2.
J Vis ; 8(12): 5.1-13, 2008 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-18831618

RESUMO

PURPOSE: This study sought to quantify divergence eye movements and differences between divergence and convergence to smoothly moving ramp, step, and disappearing step stimuli. METHODS: Eight visually normal, adult subjects participated in three experiments investigating the dynamics of responses using an infrared limbal eye tracker. RESULTS: There were four primary findings: (1) a smooth tracking behavior was observed for slow ramps while the fast ramps elicited smooth tracking combined with a high-velocity, step-like behavior; (2) the high-velocity components observed in the faster ramps had a similar main sequence as divergence steps; (3) divergence dynamics to disappearing steps starting at the subject's near dissociated phoria level were similar to corresponding step responses; and (4) the high-velocity components from divergence ramps were dependent on initial vergence position, whereas the high-velocity components from convergence ramps were not. CONCLUSION: The results suggest a preprogrammed component is present in divergence similar to convergence; however, unlike convergence, the high-velocity components from divergence ramp responses are dependent on initial vergence position.


Assuntos
Convergência Ocular/fisiologia , Movimentos Oculares/fisiologia , Percepção de Movimento/fisiologia , Adolescente , Adulto , Feminino , Humanos , Raios Infravermelhos , Masculino , Pessoa de Meia-Idade , Estimulação Luminosa/métodos , Acompanhamento Ocular Uniforme/fisiologia , Fatores de Tempo , Adulto Jovem
3.
Conf Proc IEEE Eng Med Biol Soc ; 2006: 2328-31, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17945707

RESUMO

Tissue injury and its ensuing healing process cause scar formation. In addition to physical disability, the subsequent disfigurements from burns often bring negative psychological impacts on the survivors. Scar hypertrophy and contracture limit the joint motion and body function of the patient. With fast development of the current available technologies regarding the scar therapies, not only the process of wound healing has to be focused, but also the cosmetic and functional outcomes need to be emphasized. Therefore, proper evaluation and assessment of the healing process to nil scar status is highly recommended. However, the currently employed tools for scar evaluation are mostly subjective. For example, Vancouver General Hospital (VGH) scar index uses color, pigmentation, vascularity, pliability, and depth of the scar as dependent variables for scar evaluation. These parameters only estimate the superficial surface of the scar, but they can not evaluate the deeper tissue within dermis. Ultrasound is a safe, inexpensive, and multifunctional technique for probing tissue characteristics. In addition, its resolution is not inferior to other measurement techniques. Although 3D-ultrasound is available in clinical application, it's still not widely used in scar evaluation because of its high cost. In this study, we proposed a system for scar assessment using B-mode ultrasonic technique. By utilizing the reconstruction methods to search the scar border, many characteristic parameters, including depth, area and volume, can be estimated. The proposed method is useful in assisting the clinician to evaluate the treatment effect and to plan further therapeutic strategy more objectively. In this report, the quantitative assessment system was used to evaluate the scar of a seriously burned patient. In order to verify the reliability of systematic reconstruction method, we constructed a phantom to imitate the scar tissue. The results show that it can achieve more than 90% in accuracy.


Assuntos
Queimaduras/complicações , Queimaduras/diagnóstico por imagem , Cicatriz/diagnóstico por imagem , Cicatriz/etiologia , Interpretação de Imagem Assistida por Computador/métodos , Reconhecimento Automatizado de Padrão/métodos , Ultrassonografia/métodos , Idoso , Algoritmos , Humanos , Aumento da Imagem/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Software , Ultrassonografia/instrumentação , Interface Usuário-Computador
4.
Med Eng Phys ; 26(2): 141-5, 2004 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15036181

RESUMO

Bone mineral density (BMD) is used as a clinical estimate of the risk of fracture. Ultrasound provides an alternative or complement to X-ray based methods of bone densitometry for determining BMD. Among ultrasonic characteristics, the speed of sound (SOS) is a useful tool for assessment of osteoporosis because, as recently reported, it represents a combination of density and compressibility of bone tissue. Thus, it might provide better information on bone quality to estimate the fracture risk. In this paper, a dual-transducer ultrasound technique was employed to measure the mean ultrasound propagation speed of the cortical layer as well as the cancellous layer at the tibia shaft. Encouraging results from 18 outpatients showed a high correlation (r = 0.93) between measurements of BMD and those from dual energy X-ray absorptiometry (DEXA).


Assuntos
Densidade Óssea , Densitometria/métodos , Osteoporose/diagnóstico por imagem , Tíbia/ultraestrutura , Transdutores , Ultrassonografia/instrumentação , Ultrassonografia/métodos , Absorciometria de Fóton , Idoso , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Osteoporose/fisiopatologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Estatística como Assunto , Tíbia/fisiopatologia , Tíbia/efeitos da radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA