Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
PLoS One ; 19(5): e0303149, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38722869

RESUMO

Carbon emissions have become a global challenge, and China, as the world's largest developing country, has a serious emissions problem. Developing green buildings is an important way of reducing carbon emissions. China's low-carbon city pilot policy may be an effective way of promoting green building development and reducing these emissions. This study uses the low carbon city pilot policy as a quasi-natural experiment and employs the staggered difference-in-differences method to investigate its impact on green building development. The results show that the low-carbon city pilot policy promotes green building development, and this policy promotes it by enhancing regional green innovation capacity, improving green total factor productivity at the firm and regional levels, and reducing the financing constraints of firms in the construction and real estate sectors. In addition, the promotion effect of the policy on green building development is stronger in western and non-resource-based regions and large-scale cities in China. This study contributes to the literature related to environmental policy, green building, and carbon emissions and supports the promotion of green building development and the reduction of carbon emissions.


Assuntos
Carbono , Política Ambiental , Desenvolvimento Sustentável , China , Cidades , Humanos , Indústria da Construção , Conservação dos Recursos Naturais/métodos
2.
Clin Chim Acta ; 557: 117864, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38461865

RESUMO

BACKGROUND AND AIMS: A pilot external quality assessment (EQA) scheme for molecular detection of Ureaplasma urealyticum (UU) was conducted by the National Center for Clinical Laboratories (NCCL) to evaluate the testing capabilities of clinical laboratories and the actual performance of DNA-based nucleic acid amplification tests (NAAT) and RNA-based NAATs when applied in clinical settings. MATERIALS AND METHODS: The EQA panel contained twelve lyophilized samples, including positive samples containing inactivated cell culture supernatants of UU at different concentrations and sterile saline for negative samples. The positive samples were further divided into three groups of high, moderate and low concentrations. The panels were distributed to the participants and the datasets were analyzed according to the qualitative results. RESULTS: A total of 365 laboratories participated in the EQA scheme, and 360 results submitted by 338 laboratories were collected, of which 96.11 % (346/360) of the returned results and 95.86 % (324/338) of the laboratories were deemed competent. The positive percentage agreement (PPA) was ≥ 97.5 % for high and moderate concentration samples, but varied significantly for low concentration samples, decreasing from 86.94 % to 51.94 % as the sample concentration decreased. Additionally, for low concentration samples, RNA-based NAAT showed higher PPAs than DNA-based NAATs, but these results were specific to UU supernatants used in this study. CONCLUSION: Most of UU detection assays employed by the participants were generally consistent with their estimated limit of detection (LOD), and the majority of participants can reliably detect UU samples with high and moderate concentrations, while the poor analytical performance for low concentration samples requires further improvement and optimization.


Assuntos
Técnicas de Amplificação de Ácido Nucleico , Ureaplasma urealyticum , Humanos , Ureaplasma urealyticum/genética , Técnicas de Amplificação de Ácido Nucleico/métodos , Laboratórios , RNA , DNA , China
3.
Cancer Nurs ; 47(2): 141-150, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-36728137

RESUMO

BACKGROUND: Esophageal cancer patients suffer from multiple and severe symptoms during the postoperative recovery period. Family caregivers play a vital role in assisting patients to cope with their symptoms. OBJECTIVE: To examine the concordance of esophageal cancer patients and their caregivers on assessing patients' symptoms after surgery and identify predictors associated with the symptom concordance. METHODS: In this cross-sectional study, 213 patient-caregiver dyads completed general information questionnaires, the Memorial Symptom Assessment Scale, the Depression Subscale of Hospital Anxiety and Depression Scale, the Mutuality Scale, and the Zarit Burden Interview (for caregivers). Data were analyzed using intraclass correlation coefficients, paired t tests, and binary logistic regression. RESULTS: At the dyad level, agreement of patients' and caregivers' reported symptoms ranged from poor to fair. At the group level, patients reported significantly higher scores than caregivers in most symptoms. Of the 213 dyads, 119 (55.9%) were identified as concordant on symptom assessment. Patients' nasogastric tube, perceived mutuality, caregivers' educational background, and dyad's communication frequency with each other could predict their concordance of symptom assessment. CONCLUSIONS: There were relatively low agreements between esophageal cancer patients and caregivers on assessing patients' symptoms, and caregivers tended to underestimate patients' symptoms. The dyad's symptom concordance was influenced by patient-, caregiver-, and dyad-related factors. IMPLICATIONS FOR PRACTICE: Having an awareness of the incongruence on assessing symptoms between esophageal cancer patients and caregivers may help healthcare professionals to comprehensively interpret patients' symptoms and develop targeted dyadic interventions to improve their concordance, contributing to optimal symptom management and health outcomes.


Assuntos
Cuidadores , Neoplasias Esofágicas , Humanos , Estudos Transversais , Esofagectomia/efeitos adversos , Avaliação de Sintomas , Neoplasias Esofágicas/cirurgia , Qualidade de Vida
4.
Clin Chim Acta ; 552: 117663, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38008152

RESUMO

BACKGROUND AND AIMS: The incidence and mortality rate of colorectal cancer (CRC) are increasing worldwide. Septin9 methylated (mSEPT9) DNA in circulation can be used as a non-invasive detection method to assist in the early diagnosis of CRC; however, the detection methods and procedures are complicated. This study aimed to evaluate the ability of clinical laboratories to detect Septin9 methylation in plasma cell-free DNA (cfDNA). MATERIALS AND METHODS: We prepared a sample panel consisting of positive and negative Septin9 methylation cells and CRC cells. Three positive samples with different methylation levels, one negative sample and one duplicate sample, two samples containing interference, three different CRC cell samples, and a fictitious case report were included. The panel was distributed to 59 laboratories for mSEPT9 analysis, result comparison, and scoring. RESULTS: The sample panel, validated by National Medical Products Administration (NMPA)-approved tests and targeted bisulfite sequencing, met expectations and could be used for external quality assessment (EQA). Among the 59 laboratories, 55 (93.22%) correctly reported the mSEPT9 results for all samples, while four (6.79%) reported 15 false negatives and were considered improvable. All false negatives originated from four laboratories using laboratory-developed tests (LDTs), with three failing to detect weakly positive samples, samples containing interference, and samples from different CRC cells, and one reported erroneous results on all positive samples. CONCLUSION: Our results illustrated that the detection of mSEPT9 in cfDNA is satisfactory in China. EQA is indispensable because it can help improve the diagnostic capability and quality management of the laboratories, and provide suggestions for the problems existing in mSEPT9 detection.


Assuntos
Ácidos Nucleicos Livres , Neoplasias Colorretais , Humanos , Metilação de DNA , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/genética , Laboratórios Clínicos , Biomarcadores Tumorais , Septinas/genética , Septinas/metabolismo
5.
Nat Biomed Eng ; 2023 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-37996614

RESUMO

Retinal prostheses could restore image-forming vision in conditions of photoreceptor degeneration. However, contrast sensitivity and visual acuity are often insufficient. Here we report the performance, in mice and monkeys with induced photoreceptor degeneration, of subretinally implanted gold-nanoparticle-coated titania nanowire arrays providing a spatial resolution of 77.5 µm and a temporal resolution of 3.92 Hz in ex vivo retinas (as determined by patch-clamp recording of retinal ganglion cells). In blind mice, the arrays allowed for the detection of drifting gratings and flashing objects at light-intensity thresholds of 15.70-18.09 µW mm-2, and offered visual acuities of 0.3-0.4 cycles per degree, as determined by recordings of visually evoked potentials and optomotor-response tests. In monkeys, the arrays were stable for 54 weeks, allowed for the detection of a 10-µW mm-2 beam of light (0.5° in beam angle) in visually guided saccade experiments, and induced plastic changes in the primary visual cortex, as indicated by long-term in vivo calcium imaging. Nanomaterials as artificial photoreceptors may ameliorate visual deficits in patients with photoreceptor degeneration.

6.
mSystems ; 8(6): e0058123, 2023 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-37937972

RESUMO

IMPORTANCE: Diagnosing and treating postoperative central nervous system infections (PCNSIs) remains challenging due to the low detection rate and time-consuming nature of traditional methods for identifying microorganisms in cerebrospinal fluid. Metagenomic next-generation sequencing (mNGS) technology provides a rapid and comprehensive understanding of microbial composition in PCNSIs by swiftly sequencing and analyzing the microbial genome. The current study aimed to assess the economic impact of using mNGS versus traditional bacterial culture-directed PCNSIs diagnosis and therapy in post-neurosurgical patients from Beijing Tiantan Hospital. mNGS is a relatively expensive test item, and whether it has the corresponding health-economic significance in the clinical application of diagnosing intracranial infection has not been studied clearly. Therefore, the investigators hope to explore the clinical application value of mNGS detection in PCNSIs after neurosurgery.


Assuntos
Infecções Bacterianas do Sistema Nervoso Central , Infecções do Sistema Nervoso Central , Humanos , Sequenciamento de Nucleotídeos em Larga Escala , Economia Médica , Técnicas de Apoio para a Decisão , Ensaios Clínicos Controlados Aleatórios como Assunto
7.
Clin Chem Lab Med ; 61(12): 2237-2247, 2023 11 27.
Artigo em Inglês | MEDLINE | ID: mdl-37377068

RESUMO

OBJECTIVES: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antigen detection is an indispensable tool for epidemic surveillance in the post-pandemic era. Faced with irregular performance, a comprehensive external quality assessment (EQA) scheme was conducted by the National Center for Clinical Laboratories (NCCL) to evaluate the analytical performance and status of SARS-CoV-2 antigen tests. METHODS: The EQA panel included ten lyophilized samples containing serial 5-fold dilutions of inactivated SARS-CoV-2-positive supernatants of the Omicron BA.1 and BA.5 strains and negative samples, which were classified into "validating" samples and "educational" samples. Data were analyzed according to qualitative results for each sample. RESULTS: A total of 339 laboratories in China participated in this EQA scheme, and 378 effective results were collected. All validating samples were correctly reported by 90.56 % (307/339) of the participants and 90.21 % (341/378) of the datasets. The positive percent agreement (PPA) was >99 % for samples with concentrations of 2 × 107 copies/mL but was 92.20 % (697/756) for 4 × 106 copies/mL and 25.26 % (382/1,512) for 8 × 105 copies/mL samples. Colloidal gold was the most frequently used (84.66 %, 320/378) but showed the lowest PPAs (57.11 %, 1,462/2,560) for positive samples compared with fluorescence immunochromatography (90 %, 36/40) and latex chromatography (79.01 %, 335/424). Among 11 assays used in more than 10 clinical laboratories, ACON showed a higher sensitivity than other assays. CONCLUSIONS: The EQA study can help to validate whether it's necessary to update antigen detection assays for manufacturers and provide participants with information about the performance of assays to take the first step toward routine post-market surveillance.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , Laboratórios , Pandemias , Teste para COVID-19 , Sensibilidade e Especificidade
8.
Artigo em Inglês | MEDLINE | ID: mdl-36767159

RESUMO

With the vigorous rise of online third-party recycling platforms, dual-channel recycling has become the primary recycling mode in the reverse supply chain (RSC). However, as the main body of recycling, consumers have a significant impact on the recycling process, and their behavioral preferences are rarely considered in the pricing decision of the reverse recycling supply chain. Based on the dual-channel RSC, this paper considers the competition among channels. It introduces the loss aversion behavior preference of consumers to establish a dual-channel RSC composed of remanufacturers and online and offline recyclers. This study aims to analyze the impact of consumers' loss aversion behavior on the recycling pricing and profit of each node in the green RSC and discuss the decision of recyclers under consumers' loss aversion behavior. The results show that the deeper consumers' aversion to the loss of recycling price, the lower the recycling price of dual-channel recyclers will be, which will be more conducive to the increase in the profit of online recyclers. However, the profit of remanufacturers will be reduced, and the total amount of recycling will decline. This paper considers the impact of consumer loss aversion behavior on dual-channel reverse supply chain pricing decisions based on prospect theory. It provides references for chain members to set recycling prices to increase people's enthusiasm for recycling and the amount of recycled scrap, contributes to the cause of resource conservation and environmental protection, and improves the economic efficiency of recycling enterprises.


Assuntos
Comércio , Reutilização de Equipamento , Humanos , Comportamento do Consumidor , Conservação dos Recursos Naturais , Custos e Análise de Custo , Reciclagem/métodos
9.
J Radiol Prot ; 41(2)2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-33508813

RESUMO

During long-pulse deuterium plasma operations in the Experimental Advanced Superconducting Tokamak (EAST), a mixed radiation field is generated, which is mainly composed of fusion neutrons, gamma rays, and x-rays. More accurate and effective dose monitoring methods have been developed and established to determine the ionizing radiation intensity both for the stable operation of the device and for the radiation safety of personnel. As far as we know, there are few reports about the biological effects of radiation induced by fusion neutrons andγradiation, which are of vital importance for the assessment of radiation hazards presented by fusion devices, such as EAST, to human beings and the environment. In this study, three positions in the EAST hall were selected to detect genotoxic effects induced by nuclear fusion radiation using aVicia fabamicronucleus (MN) test for the first time. The doses of neutrons and gamma rays at these places were measured by thermoluminescence dosimeters four times between June 2019 and May 2020. The radiation doses decreased as the distances from the EAST device shell gradually increased from S1 to S3. The radiation in the EAST hall resulted in a significant induction of MN in theVicia fabaroot tip cells compared to a negative control, which was different from the MN frequency induced by fission neutrons,γ-rays and other kinds of radiation in previous studies. These results indicate the existence of potential genotoxic effects induced by radiation from EAST which is different from other radiation and suggest that personnel should not be permitted to enter the experimental hall during the discharge process, and that radiation protection measures should be taken during necessary maintenance to avoid radiation damage. These newly acquired results will certainly increase our knowledge about the biological effects induced by radiation from nuclear fusion and provide good data support for developing more effective environmental and personnel fusion radiation protection.


Assuntos
Dano ao DNA , Nêutrons , Bioensaio , Relação Dose-Resposta à Radiação , Raios gama/efeitos adversos , Humanos , Raios X
10.
J Mol Diagn ; 23(1): 19-28, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33122140

RESUMO

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) poses a huge threat to public health. Viral nucleic acid testing is the diagnostic gold standard and can play an important role in the prevention and control of this infection. In this study, bacteriophage MS2 virus-like particles encapsulating specific RNA sequences of SARS-CoV-2 and other coronaviruses were prepared by genetic engineering. The assessment panel, consisting of four positive samples with concentrations of 2.8, 3.5, 4.2, and 4.9 log10 copies/mL and five negative samples with other human coronaviruses, was prepared and distributed to evaluate the accuracy of routine viral RNA detection. Results of 931 panels from 844 laboratories were collected. The overall percentage agreement, positive percentage agreement (PPA), and negative percentage agreement, defined as the percentage of agreement between the correct results and total results submitted for all, positive, and negative samples were 96.8% (8109/8379), 93.9% (3497/3724), and 99.1% (4612/4655), respectively. For samples with concentrations of 4.9 and 4.2 log10 copies/mL, the PPAs were >95%. However, for 3.5 and 2.8 log10 copies/mL, the PPAs were 94.6% (881/931) and 84.9% (790/931), respectively. For all negative samples, the negative percentage agreement values were >95%. Thus, most laboratories can reliably detect SARS-CoV-2. However, further improvement and optimization are required to ensure the accuracy of detection in panel members with lower concentrations of viral RNA.


Assuntos
Teste de Ácido Nucleico para COVID-19/métodos , COVID-19/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , SARS-CoV-2/genética , Humanos , Levivirus/genética , Técnicas de Amplificação de Ácido Nucleico , RNA Viral/genética , Reação em Cadeia da Polimerase em Tempo Real/métodos , Sensibilidade e Especificidade
11.
BMC Nephrol ; 21(1): 135, 2020 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-32295531

RESUMO

BACKGROUND: Lack of accurate and effective assessment tools of fluid status is one of the major challenges to reach proper dry weight (DW) in chronic hemodialysis (HD) population. The aim of this randomized study was to evaluate the effect of bioimpedance guided DW assessment on long-term outcomes in Chinese HD patients. Eligible patients were randomly assigned (1:1) to two groups in each center, the control group and body composition monitor (BCM) group. In the BCM group, DW has been evaluated by bioimpedance technic every 2 months during follow-up. The primary composite endpoint consisted of death, acute myocardial infarction, cerebral infarction, cerebral hemorrhage, and peripheral vascular disease. METHODS: A total of 445 patients were recruited from 11 hemodialysis centers from Beijing, Tianjin and Shijiazhuang cities from Jan 1, 2013 to Dec 31, 2014. They were randomized into either BCM group or control group. All patients have been followed up for 1 year or until Dec 31, 2014 or censoring. RESULTS: At baseline, there were no significant differences between two groups in terms of demographic parameters, dialysis vintage, percentage of vascular access, and comorbid conditions. At the end of the study, 18 (4.04%) patients had died (11 in control group and 7 in BCM group). Kaplan-Meier survival analysis showed no significant difference in survival rates between two groups (log-rank test P = 0.07). However, there was an increasing trend of survival rates in BCM group compared to the control group. In the multivariable Cox analysis, there was a nonsignificant trend toward less primary composite end points in the BCM group in the adjusted analysis, the hazard ratio was impressive (0.487, 95% CI 0.217-1.091, P = 0.08). CONCLUSION: Bioimpedance technic has been applied to assess fluid status for decades and has been proved to be a promising tool for clinical practice. Although short-term outcomes were not improved in the randomized, controlled trial, the ascending trend in survival has been observed. Further studies are needed to investigate the survival benefit of bioimpedance method in DW assessment in a larger sample with longer follow-up period. TRIAL REGISTRATION: ClinicalTrials.org, NCT01509937. Registered 13 January 2012.


Assuntos
Composição Corporal , Impedância Elétrica , Falência Renal Crônica , Efeitos Adversos de Longa Duração/diagnóstico , Monitorização Fisiológica/métodos , Diálise Renal , Líquidos Corporais , Pesos e Medidas Corporais/métodos , China/epidemiologia , Feminino , Humanos , Falência Renal Crônica/diagnóstico , Falência Renal Crônica/mortalidade , Falência Renal Crônica/terapia , Masculino , Pessoa de Meia-Idade , Diálise Renal/efeitos adversos , Diálise Renal/métodos , Análise de Sobrevida , Equilíbrio Hidroeletrolítico
12.
Kidney Int Suppl (2011) ; 10(1): e63-e71, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32149010

RESUMO

Achievement of equity in health requires development of a health system in which everyone has a fair opportunity to attain their full health potential. The current, large country-level variation in the reported incidence and prevalence of treated end-stage kidney disease indicates the existence of system-level inequities. Equitable implementation of kidney replacement therapy (KRT) programs must address issues of availability, affordability, and acceptability. The major structural factors that impact equity in KRT in different countries are the organization of health systems, overall health care spending, funding and delivery models, and nature of KRT prioritization (transplantation, hemodialysis or peritoneal dialysis, and conservative care). Implementation of KRT programs has the potential to exacerbate inequity unless equity is deliberately addressed. In this review, we summarize discussions on equitable provision of KRT in low- and middle-income countries and suggest areas for future research.

13.
Sci Total Environ ; 586: 174-187, 2017 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-28185732

RESUMO

An innovative ecosystem services-based sustainability assessment was conducted in the important urban agglomeration of the Lake Biwa region, Japan, covering the time period from 1950 to 2014. A 22-indicator system was established that was based on the major ecosystem services of Lake Biwa and its water courses, i.e., provisioning services regarding aquatic products and water; regulating services regarding floods and water quality; cultural services regarding recreation and tourism, scientific research, and environmental education; and supporting services regarding biodiversity. First, changes in the eight ecosystem services were discussed together with the considerable experience and difficult lessons that can be drawn from the development trajectory. Next, with the indicators rearranged according to sustainability principles, the regional sustainability over the past six-plus decades was assessed. In general, this urban agglomeration has been progressing in terms of its sustainability, although economic and social development was achieved at the cost of environmental degradation in the past, and the current economic downturn is hurting the balanced development and integrated benefits. The results lead directly to recommendations for regional development, especially in terms of economic rejuvenation, from the perspective of improving management of Lake Biwa's water resources. Moreover, the relevant knowledge is educational and inspirational for other places in the world that are facing similar development issues. For example, the effective and even pioneering countermeasures that have been taken against environmental degradation, as well as the participation and collaboration of multiple stakeholders, could be useful as a model. Moreover, the study invites increased understanding of ecosystem vulnerability to anthropogenic devastation and emphasizes the priority of precautionary measures over countermeasures in the context of holistic urban planning and sustainable urban development.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA