Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38084985

RESUMO

BACKGROUND AND OBJECTIVES: The correct positioning of the transverse-sigmoid sinus junction (TSSJ) during retrosigmoid craniotomy (RC) is crucial for enhancing surgical efficiency and preventing complications. An augmented reality technology may provide low-cost guidance for the TSSJ position. The authors aimed to investigate the clinical application of a self-developed mobile augmented reality navigation system (MARNS) for TSSJ positioning during RC and present their findings. METHODS: This observational research enrolled patients who underwent RC at Fujian Provincial Hospital from May 2023 to June 2023. All patients had their TSSJs located by MARNS. The surgical incision and skull "keyhole" for drilling were determined separately based on the projections of TSSJ on the 3-dimensional model displayed by MARNS. This method was assessed using matching error, positioning time, integrity of the bone flap, incidence of transversal sigmoid sinus injury, and other complications. RESULTS: Seven patients diagnosed with acoustic neuroma, trigeminal neuralgia, and hemifacial spasm were enrolled in this study. The MARNS system exhibited a matching error with an average magnitude of 2.88 ± 0.69 mm. The positioning procedure necessitated an average duration of 279.71 ± 27.29 seconds. In every instance, the inner edge of the TSSJ was precisely identified and exposed while the bone flap was successfully formed and maintained an average integrity of 86.7%. CONCLUSION: This study demonstrated the efficacy of MARNS in the precise placement of the TSSJ during RC procedures. It offers advantages for convenience, cost-effectiveness, and reliability for neurosurgical navigation.

2.
BMC Musculoskelet Disord ; 24(1): 492, 2023 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-37322501

RESUMO

INTRODUCTION: The objective of this study was to investigate the ankle alignment alterations after the correction of knee varus deformity in MAKO robot-assisted total knee arthroplasty (MA-TKA). METHODS: A retrospective analysis was conducted for 108 patients with TKA from February 2021 to February 2022. Patients were divided into two groups based on MAKO robot involvement during the procedure: the MA-TKA group (n = 36) and the conventional manual total knee arthroplasty (CM-TKA) group (n = 72). The patients were divided into four subgroups according to the degree of surgical correction of the knee varus deformity. Seven radiological measurements were evaluated pre and post-surgery: mechanical tibiofemoral angle (mTFA), mechanical lateral distal femoral angle (mLDFA), medial proximal tibial angle (MPTA), lateral distal tibial angle (LDTA), tibial plafond inclination angle (TPIA), talar inclination angle (TIA), and tibiotalar tilt angle (TTTA). TTTA is a quantitative representation of the extent of ankle incongruence. RESULTS: The number of mTFA, mLDFA, and MPTA outliers in the MA-TKA group was significantly lower compared to the CM-TKA group (P<0.05). Knee varus deformity was properly corrected and the mechanical axis was restored in all patients, regardless of the treatment group. Only for varus corrections ≥ 10° did TTTA change significantly (p < 0.01) and ankle varus incongruence aggravate post-operation. The ΔTTTA correlated negatively with ΔTFA (r=-0.310,P = 0.001) and correlated positively with ΔTPIA (r = 0.490,P = 0.000). When the varus correction was ≥ 7.55°, the probability of ankle varus incongruence exacerbation increased 4.86-fold. CONCLUSION: Compared with CM-TKA, MA-TKA osteotomy showed more precision but was unable to reduce post-operation ankle varus incongruence. When the varus correction ≥ 10°, ankle varus incongruence aggravated, while when the varus correction ≥ 7.55°, the probability of ankle varus incongruence increased 4.86-fold. This may occasion the pathogenesis of ankle pain following TKA.


Assuntos
Artroplastia do Joelho , Genu Varum , Osteoartrite do Joelho , Robótica , Humanos , Artroplastia do Joelho/efeitos adversos , Tornozelo/cirurgia , Genu Varum/cirurgia , Estudos Retrospectivos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Osteoartrite do Joelho/cirurgia
3.
BMC Geriatr ; 21(1): 377, 2021 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-34154560

RESUMO

BACKGROUND: Comprehensive geriatric assessment (CGA) interventions can improve functional ability and reduce mortality in older adults, but the effectiveness of CGA intervention on the quality of life, caregiver burden, and length of hospital stay remains unclear. The study aimed to determine the effectiveness of CGA intervention on the quality of life, length of hospital stay, and caregiver burden in older adults by conducting meta-analyses of randomised controlled trials (RCTs). METHODS: A literature search in PubMed, Embase, and Cochrane Library was conducted for papers published before February 29, 2020, based on inclusion criteria. Standardised mean difference (SMD) or mean difference (MD) with 95% confidence intervals (CIs) was calculated using the random-effects model. Subgroup analyses, sensitivity analyses, and publication bias analyses were also conducted. RESULTS: A total of 28 RCTs were included. Overall, the intervention components common in different CGA intervention models were interdisciplinary assessments and team meetings. Meta-analyses showed that CGA interventions improved the quality of life of older people (SMD = 0.12; 95% CI = 0.03 to 0.21; P = 0.009) compared to usual care, and subgroup analyses showed that CGA interventions improved the quality of life only in participants' age > 80 years and at follow-up ≤3 months. The change value of quality of life in the CGA intervention group was better than that in the usual care group on six dimensions of the 36-Item Short-Form Health Survey questionnaire (SF-36). Also, compared to usual care, the CGA intervention reduced the caregiver burden (SMD = - 0.56; 95% CI = - 0.97 to - 0.15, P = 0.007), but had no significant effect on the length of hospital stay. CONCLUSIONS: CGA intervention was effective in improving the quality of life and reducing caregiver burden, but did not affect the length of hospital stay. It is recommended that future studies apply the SF-36 to evaluate the impact of CGA interventions on the quality of life and provide supportive strategies for caregivers as an essential part of the CGA intervention, to find additional benefits of CGA interventions.


Assuntos
Avaliação Geriátrica , Qualidade de Vida , Idoso , Idoso de 80 Anos ou mais , Sobrecarga do Cuidador , Cuidadores , Humanos , Tempo de Internação , Ensaios Clínicos Controlados Aleatórios como Assunto
4.
Br J Neurosurg ; 35(5): 597-602, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34092175

RESUMO

PURPOSE: In this study, a simulator for training lateral ventricular puncture (LVP) was developed using three-dimensional (3D) printing technology, and its function of improving the skills of LVP in young interns was evaluated. METHODS: A virtual 3D craniocerebral simulator of a 51-year-old female patient with hydrocephalus was reconstructed with 3D printing technology. The anatomical and practical validity were assessed by all interns on a 13-item Likert scale. The usefulness of this simulator was evaluated once a week by two neurosurgeons, based on the performance of the interns, using the objective structured assessment of technical skills (OSATS) scale. RESULTS: The Likert scale showed that all participants agreed with the overall appearance of the simulator. Also, the authenticity of the skull was the best, followed by the lateral ventricles, analog generation system of intraventricular pressure, cerebrum, and the scalp. This simulator could help the participants' learning about the anatomy of the lateral ventricle, effective training, and repeating the steps of LVP. During training, the interns' ratio of success in LVP elevated gradually. At each evaluation stage, all mean performance scores for each measure based on the OSATS scale were higher than the previous. CONCLUSIONS: The 3D printed simulator for LVP training provided both anatomical and practical validity, and enabled young doctors to master the LVP procedures and skills.


Assuntos
Ventrículos Laterais , Crânio , Competência Clínica , Feminino , Humanos , Ventrículos Laterais/cirurgia , Pessoa de Meia-Idade , Neurocirurgiões , Impressão Tridimensional , Punções
5.
J Hosp Med ; 13(1): 52-61, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29309438

RESUMO

BACKGROUND: Imaging use in the diagnostic workup of pulmonary embolism (PE) has increased markedly in the last 2 decades. Low PE prevalence and diagnostic yields suggest a significant problem of overuse. PURPOSE: The purpose of this systematic review is to summarize the evidence associated with the interventions aimed at reducing the overuse of imaging in the diagnostic workup of PE in the emergency department and hospital wards. DATA SOURCES: PubMed, MEDLINE, Embase, and EBM Reviews from 1998 to March 28, 2017. STUDY SELECTION: Experimental and observational studies were included. The types of interventions, their efficacy and safety, the impact on healthcare costs, the facilitators, and barriers to their implementation were assessed. DATA SYNTHESIS: Seventeen studies were included assessing clinical decision support (CDS), educational interventions, performance and feedback reports (PFRs), and institutional policy. CDS impact was most comprehensively documented. It was associated with a reduction in imaging use, ranging from 8.3% to 25.4%, and an increase in diagnostic yield, ranging from 3.4% to 4.4%. The combined implementation of a CDS and PFR resulted in a modest but significant increase in the adherence to guidelines. Few studies appraised the safety of interventions. There was a lack of evidence concerning economic aspects, facilitators, and barriers. CONCLUSIONS: A combined implementation of an electronic CDS and PFRs is more effective than purely educational or policy interventions, although evidence is limited. Future studies of high-methodological quality would strengthen the evidence concerning their efficacy, safety, facilitators, and barriers.


Assuntos
Uso Excessivo dos Serviços de Saúde/prevenção & controle , Embolia Pulmonar/diagnóstico por imagem , Sistemas de Apoio a Decisões Clínicas/economia , Sistemas de Apoio a Decisões Clínicas/estatística & dados numéricos , Serviço Hospitalar de Emergência , Retroalimentação , Gastos em Saúde , Humanos , Capacitação em Serviço/organização & administração , Segurança do Paciente , Políticas , Embolia Pulmonar/economia
6.
Acta Radiol ; 58(6): 660-669, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27650033

RESUMO

Background Coronary computed tomography angiography (CTA) allows the evaluation of coronary plaque volume and low attenuation (lipid-rich) component, for plaque vulnerability assessment. Purpose To determine the effect of iterative reconstruction (IR) on coronary plaque volume and composition. Material and Methods Consecutive patients without coronary artery disease were prospectively enrolled for 256-slice CT. Images were reconstructed with both filtered back projection (FBP) and a hybrid IR algorithm (iDose4, Philips) levels 1, 3, 5, and 7. Coronary plaques were assessed according to predefined Hounsfield unit (HU) attenuation intervals, for total plaque and HU-interval volumes. Results Fifty-three patients (mean age, 53.6 years) were included. Noise was significantly decreased and signal-to-noise ratio (SNR) / contrast-to-noise (CNR) were both significantly improved at all IR levels in comparison to FBP. Plaque characterization was performed in 41 patients for a total of 125 plaques. Total plaque volume ranged from 104.4 ± 120.7 to 107.4 ± 128.9 mm3 and low attenuation plaque component from 40.5 ± 54.7 to 43.5 ± 58.9 mm3, with no statistically significant differences between all IR levels and FBP ( P = 0.786 and P ≥ 0.078, respectively). Conclusion IR improved image quality. Total and low attenuation plaque volumes were similar using either IR or FBP.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico por imagem , Algoritmos , Doença da Artéria Coronariana/patologia , Estudos Transversais , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/patologia
7.
Transplantation ; 79(7): 768-76, 2005 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-15818318

RESUMO

BACKGROUND: Pancreatic islet transplantation is an emerging therapy for type 1 diabetes, but it is difficult to assess islets after transplantation and thus to design interventions to improve islet survival. METHODS: To image and quantify islets, the authors transplanted luciferase-expressing murine or human islets (by adenovirus-mediated gene transfer) into the liver or beneath the renal capsule of immunodeficient mice and quantified the in vivo bioluminescence imaging (BLI) of mice using a cooled charge-coupled device camera and digital photon-counting image analysis. To account for variables that are independent of islet mass such as transplant site, animal positioning, and wound healing, the BLI of transplanted islets was calibrated against measurement of luminescence of an implanted bead emitting a constant light intensity. RESULTS: BLI of mice bearing islet transplants was seen in the expected anatomic location, was stable for more than 8 weeks after transplantation, and correlated with the number of islets transplanted into the liver or kidney. BLI of the luminescent bead and of transplanted islets in the kidney was approximately four times greater than when transplanted in the liver, indicating that photon emission is dependent on optical absorption of generated light and thus light source location. CONCLUSION: In vivo BLI allows for quantitative, serial measurements of pancreatic islet mass after transplantation and should be useful in assessing interventions to sustain or increase islet survival of transplanted islets.


Assuntos
Transplante das Ilhotas Pancreáticas , Ilhotas Pancreáticas/citologia , Animais , Sobrevivência de Enxerto , Humanos , Imageamento Tridimensional , Ilhotas Pancreáticas/crescimento & desenvolvimento , Ilhotas Pancreáticas/patologia , Medições Luminescentes , Camundongos
8.
Mol Imaging ; 3(4): 333-42, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15802050

RESUMO

The aim of this study is to determine and characterize factors influencing in vivo bioluminescence imaging (BLI) and apply them to the specific application of imaging transplanted pancreatic islets. Noninvasive quantitative assessment of transplanted pancreatic islets poses a formidable challenge. Murine pancreatic islets expressing firefly luciferase were transplanted under the renal capsule or into the portal vein of nonobese diabetic-severe combined immunodeficiency mice and the bioluminescence was quantified with a cooled charge coupled device camera and digital photon image analysis. The important, but often neglected, effects of wound healing, mouse positioning, and transplantation site on bioluminescence measurements were investigated by imaging a constant emission, isotropic light-emitting bead (lambda = 600) implanted at the renal or hepatic site. The renal beads emitted nearly four times more light than hepatic beads with a smaller spot size, indicating that light absorption and scatter are greatly influenced by the transplant site and must be accounted for in BLI measurements. Detected luminescence decreased with increasing angle between the mouse surface normal and optical axis. By defining imaging parameters such as postsurgical effects, animal positioning, and light attenuation as a function of transplant site, this study develops BLI as a useful imaging modality for quantitative assessment of islets post-transplantation.


Assuntos
Transplante das Ilhotas Pancreáticas , Medições Luminescentes/métodos , Animais , Genes Reporter , Transplante das Ilhotas Pancreáticas/fisiologia , Luciferases de Vaga-Lume/genética , Medições Luminescentes/estatística & dados numéricos , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Endogâmicos DBA , Camundongos Endogâmicos NOD , Camundongos SCID , Método de Monte Carlo , Proteínas Recombinantes/genética , Transdução Genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA