Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Int J Infect Dis ; 126: 136-144, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36343866

RESUMO

OBJECTIVES: Rabies is an acute lethal infectious disease caused by a lyssavirus infection. In 2018, the World Health Organization proposed a global strategic plan to end human rabies deaths by 2030. However, systematic studies on the global rabies disease burden and epidemiological trends are scarce. METHODS: We extracted the disease burden and epidemiological data of rabies worldwide in the preceding 30 years from the Global Burden of Disease Study 2019 and performed a comprehensive analysis. RESULTS: In 2019, the incident cases of rabies worldwide were 14,075.51 (95% uncertainty interval: 6124.33-21,618.11), and the number of deaths was 13,743.44 (95% uncertainty interval: 6019.13-17,938.53), both of which were lower than that in 1990. With the improvement of the sociodemographic index, the incident cases, the number of deaths, age-standardized incidence rate, age-standardized incidence death rate, and disability-adjusted life years of rabies all showed downward trends. Adolescents and adults aged <50 years represented the majority of rabies cases worldwide. CONCLUSION: The global disease burden of rabies has declined over the past 30 years. Furthermore, the disease burden of rabies was closely related to the sociodemographic index level.


Assuntos
Carga Global da Doença , Raiva , Adulto , Adolescente , Humanos , Raiva/epidemiologia , Incidência , Saúde Global , Organização Mundial da Saúde , Anos de Vida Ajustados por Qualidade de Vida
2.
Artigo em Inglês | MEDLINE | ID: mdl-36429381

RESUMO

BACKGROUND: The credible materials about the burden of asthma in China when compared to other countries in the group of twenty (G20) remain unavailable. OBJECTIVES AND DESIGN: Following the popular analysis strategy used in the Global Burden of Disease Study, the age-, sex-, country-specific prevalence, and disability-adjusted life years (DALYs) of asthma in China were analyzed. Meanwhile, the comparison in trends between China and other countries in the G20 was also evaluated. RESULTS: In 2019, asthma was the 8th leading cause of the DALYs' burden of 369 diseases in China. From 1990 to 2019, the age-standardized prevalence and DALY rates of asthma in China decreased by 14% and 51%, respectively; further, the decline rate of DALYs was much higher than the global average (-51%: -43%). It is worth noting that the overall population age-standardized DALYs rate of asthma in China was the lowest in the G20 during 2019 (102.81, 95% UI: (72.30,147.42)/100,000). Moreover, the age-standardized asthma prevalence rate peaks in both childhood (178.14, 95% UI: (90.50, 329.01)/100,000) and the elderly (541.80, 95% UI: (397.79, 679.92)/100,000). Moreover, throughout the study, subjects in the 5 to 9 years old interval were a constant focus of our attention. CONCLUSIONS: The disease burden of asthma has varied greatly by gender and age over the past 30 years. In contrast to the increasing burden in most other G20 countries, the age-standardized prevalence rate of asthma shows a significant decreasing trend in China, however, the age-standardized DALYs rate shows a fluctuating change, and has even shown a rebound trend in recent years.


Assuntos
Asma , Carga Global da Doença , Humanos , Criança , Idoso , Adulto , Pré-Escolar , Prevalência , Anos de Vida Ajustados por Qualidade de Vida , Anos de Vida Ajustados por Deficiência , China/epidemiologia , Asma/epidemiologia
3.
Biomed Phys Eng Express ; 7(3)2021 04 22.
Artigo em Inglês | MEDLINE | ID: mdl-33836524

RESUMO

Purpose. To compare the accuracies of the AAA and AcurosXB dose calculation algorithms and to predict the change in the down-stream and lateral dose deposition of high energy photons in the presence of material with densities higher that commonly found in the body.Method. Metal rods of titanium (d = 4.5 g cm-3), stainless steel (d = 8 g cm-3) and tungsten (d = 19.25 g cm-3) were positioned in a phantom. Film was position behind and laterally to the rods to measure the dose distribution for a 6 MV, 18 MV and 10 FFF photon beams. A DOSXYZnrc Monte Carlo simulation of the experimental setup was performed. The AAA and AcurosXB dose calculation algorithms were used to predict the dose distributions. The dose from film and DOSXYZnrc were compared with the dose predicted by AAA and AcurosXB.Results. AAA overestimated the dose behind the rods by 15%-25% and underestimated the dose laterally to the rods by 5%-15% depending on the range of materials and energies investigated. AcurosXB overestimated the dose behind the rods by 1%-18% and underestimated the dose laterally to the rods by up to 5% depending on the range of material and energies investigated.Conclusion. AAA cannot deliver clinically acceptable dose calculation results at a distance less than 10 mm from metals, for a single field treatment. Acuros XB is able to handle metals of low atomic numbers (Z ≤ 26), but not tungsten (Z = 74). This can be due to the restriction of the CT-density table in EclipseTMTPS, which has an upper HU limit of 10501.


Assuntos
Algoritmos , Planejamento da Radioterapia Assistida por Computador , Metais , Método de Monte Carlo , Imagens de Fantasmas , Fótons
4.
J Appl Clin Med Phys ; 17(3): 475-485, 2016 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-27167252

RESUMO

The metallic fixations used in surgical procedures to support the spine mechani-cally usually consist of high-density materials. Radiation therapy to palliate spinal cord compression can include prophylactic inclusion of potential tumor around the site of such fixation devices. Determination of the correct density and shape of the spine fixation device has a direct effect on the dose calculation of the radiation field. Even with the application of modern computed tomography (CT), under- or overestimation of dose, both immediately next to the device and in the surround-ing tissues, can occur due to inaccuracies in the dose prediction algorithm. In this study, two commercially available dose prediction algorithms (Eclipse AAA and ACUROS), EGSnrc Monte Carlo, and GAFchromic film measurements were com-pared for a clinical spine SBRT case to determine their accuracy. An open six-field plan and a clinical nine-field IMRT plan were applied to a phantom containing a metal spine fixation device. Dose difference and gamma analysis were performed in and around the tumor region adjacent to the fixation device. Dose calculation inconsistency was observed in the open field plan. However, in the IMRT plan, the dose perturbation effect was not observed beyond 5 mm. Our results suggest that the dose effect of the metal fixation device to the spinal cord and the tumor volume is not observable, and all dose calculation algorithms evaluated can provide clinically acceptable accuracy in the case of spinal SBRT, with the tolerance of 95% for gamma criteria of 3%/3 mm.


Assuntos
Algoritmos , Metais/química , Imagens de Fantasmas , Radiocirurgia/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Neoplasias da Coluna Vertebral/cirurgia , Simulação por Computador , Humanos , Método de Monte Carlo , Radiocirurgia/métodos , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA