Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Open Heart ; 11(1)2024 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-38238026

RESUMO

INTRODUCTION: Three recent randomised controlled trials have demonstrated that pulmonary vein isolation as an initial rhythm control strategy with cryoablation reduces atrial arrhythmia recurrence in patients with symptomatic paroxysmal atrial fibrillation (PAF) compared with antiarrhythmic drug (AAD) therapy. The aim of this study was to evaluate the cost-effectiveness of first-line cryoablation compared with first-line AADs for treating symptomatic PAF in an English National Health Service (NHS) setting. METHODS: Individual patient-level data from 703 participants with PAF enrolled into Cryo-FIRST (Catheter Cryoablation Versus Antiarrhythmic Drug as First-Line Therapy of Paroxysmal Atrial Fibrillation), STOP AF First (Cryoballoon Catheter Ablation in an Antiarrhythmic Drug Naive Paroxysmal Atrial Fibrillation) and EARLY-AF (Early Aggressive Invasive Intervention for Atrial Fibrillation) were used to derive the parameters applied in the cost-effectiveness model (CEM). The CEM comprised a hybrid decision tree and Markov structure. The decision tree had a 1-year time horizon and was used to inform the initial health state allocation in the first cycle of the Markov model (40-year time horizon; 3-month cycle length). Health benefits were expressed in quality-adjusted life years (QALYs). Costs and benefits were discounted at 3.5% per year. Model outcomes were generated using probabilistic sensitivity analysis. RESULTS: The results estimated that cryoablation would yield more QALYs (+0.17) and higher costs (+£641) per patient over a lifetime than AADs. This produced an incremental cost-effectiveness ratio of £3783 per QALY gained. Independent of initial treatment, individuals were expected to receive ~1.2 ablations over a lifetime. There was a 45% relative reduction in time spent in AF health states for those initially treated with cryoablation. DISCUSSION: AF rhythm control with first-line cryoablation is cost effective compared with first-line AADs in an English NHS setting.


Assuntos
Fibrilação Atrial , Criocirurgia , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Análise Custo-Benefício , Medicina Estatal , Antiarrítmicos/efeitos adversos , Criocirurgia/efeitos adversos , Criocirurgia/métodos
2.
Can J Cardiol ; 40(4): 576-584, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38007219

RESUMO

BACKGROUND: The EARLY-AF (NCT02825979), STOP AF First (NCT03118518), and Cryo-FIRST (NCT01803438) randomised controlled trials (RCTs) demonstrated that cryoballoon pulmonary vein isolation reduces atrial fibrillation (AF) recurrence compared with antiarrhythmic drugs (AADs) in patients with symptomatic paroxysmal atrial fibrillation (PAF). The present study developed a cost-effectiveness model (CEM) of first-line cryoablation compared with first-line AADs for PAF, from the Canadian health care payer's perspective. METHODS: Data from the 3 RCTs were analysed to estimate key CEM parameters. The model structure used a decision tree for the first 12 months and a Markov model with a 3-month cycle length for the remaining lifetime time horizon. Costs were set at 2023 Canadian dollars, health benefits were expressed as quality-adjusted life years (QALYs), and both were discounted 3% annually. Probabilistic sensitivity analysis (PSA) considered parameter uncertainty. RESULTS: The statistical analysis estimated that first-line cryoablation generates a 47% reduction (P < 0.001) in the rate of AF recurrence, a 73% reduction in the rate of subsequent ablation (P < 0.001), and a 4.3% (P = 0.025) increase in health-related quality of life, compared with first-line AADs. The PSA indicates that an individual treated with first-line cryoablation accrues less costs (-$3,862) and more QALYs (0.19) compared with first-line AADs. Cryoablation is cost-saving in 98.4% of PSA iterations and has a 99.9% probability of being cost-effective at a cost-effectiveness threshold of $50,000 per QALY gained. Cost-effectiveness results were robust to changes in key model parameters. CONCLUSIONS: First-line cryoballoon ablation is cost-effective when compared with AADs for patients with symptomatic PAF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Humanos , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Análise Custo-Benefício , Antiarrítmicos/uso terapêutico , Ablação por Cateter/métodos , Canadá/epidemiologia , Resultado do Tratamento , Recidiva
3.
J Cardiovasc Electrophysiol ; 34(11): 2393-2397, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37792572

RESUMO

INTRODUCTION: Pulmonary vein isolation (PVI) with thermal energy is characterized by concomitant ablation of the surrounding ganglionated plexi (GP). Pulsed-field ablation (PFA) selectively targets the myocardium and seems associated with only negligible effects on the autonomic nervous system (ANS). However, little is known about the dynamic effects of PFA on the GP immediately after PVI. This study sought to investigate the degree and acute vagal modulation induced by the FarapulseTM PFA system during PVI compared with single-shot thermal ablation. METHODS: A total of 76 patients underwent first-time PVI with either FarapulseTM PFA (PFA group, n = 40) or cryoballoon ablation (thermal ablation group, n = 36) for paroxysmal atrial fibrillation (AF). The effect on the ANS in the two groups was assessed before and after PVI with extracardiac vagal stimulation (ECVS). To capture any transient effects of PFA on the ANS, in a subgroup of PFA patients ECVS was repeated at three predefined timepoints: (1) before PVI (T0); (2) immediately after PVI (T1); and (3) 10 min after the last energy application (T2). RESULTS: Despite similar baseline values, the vagal response induced by ECVS after PVI almost disappeared in the thermal ablation group but persisted in the PFA group (thermal group: 840 [706-1090] ms, p < .001 compared to baseline; PFA group: 11 466 [8720-12 293] ms, p = .70 compared to baseline). Intraprocedural vagal reactions (defined as RR increase >50%, transitory asystole, or atrioventricular block) occurred more frequently with PFA than thermal ablation (70% vs. 28%, p = .001). Moreover, heart rate 24 h post-PVI increased more with thermal ablation than with PFA (16.5 ± 9.0 vs. 2.6 ± 6.1 beats/min, p < .001). In the subgroup of PFA patients undergoing repeated ANS modulation assessment (n = 11), ECVS demonstrated that PFA determined a significant acute suppression of the vagal response immediately after PVI (p < .001 compared to baseline), which recovered almost completely within 10 min. CONCLUSION: PVI with the FarapulseTM PFA system is associated with only transitory and short-lasting vagal effects on the ANS which recover almost completely within a few minutes after ablation. The impact of this phenomenon on AF outcome needs to be further investigated.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Sistema Nervoso Autônomo/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Nervo Vago/cirurgia , Frequência Cardíaca , Ablação por Cateter/efeitos adversos , Resultado do Tratamento
4.
Heart Rhythm O2 ; 4(9): 528-537, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37744940

RESUMO

Background: Three recent randomized controlled trials have demonstrated that, as an initial rhythm control strategy, first-line cryoballoon ablation (cryoablation) reduces atrial arrhythmia recurrence compared with antiarrhythmic drugs (AADs) in patients with symptomatic paroxysmal atrial fibrillation (PAF). Objective: The study sought to evaluate the cost-effectiveness of first-line cryoablation compared with first-line AADs for treating symptomatic PAF from a U.S. Medicare payer perspective. Methods: Individual patient-level data from 703 participants with PAF enrolled into the Cryo-FIRST (NCT01803438), STOP AF First (NCT03118518), and EARLY-AF (NCT02825979) trials were used to derive parameters for the cost-effectiveness model. The cost-effectiveness model used a hybrid decision tree and Markov structure. The decision tree had a 1-year time horizon and was used to inform the initial health state allocation in the first cycle of the Markov model. The Markov model used a 40-year time horizon (3-month cycle length). Health benefits were expressed in quality-adjusted life years (QALYs). Costs and benefits were discounted at 3% per year. Results: Cryoablation was estimated to yield higher QALYs (+0.17) and higher costs (+$4274) per patient over a 40-year time horizon than AADs. Ultimately, this produced an average incremental cost-effectiveness ratio of $24,637 per QALY gained. Independent of initial treatment, individuals were expected to receive ∼1.2 ablations over a lifetime. There was a 45% relative reduction in time spent in atrial fibrillation health states for those initially treated with cryoablation compared with AADs. Conclusion: Initial rhythm control with first-line cryoballoon ablation is highly cost-effective compared with first-line AADs from a U.S. Medicare payer perspective.

5.
Front Cardiovasc Med ; 10: 1086791, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37123474

RESUMO

Background: The novel DiamondTemp ablation system (DTA) and EnSiteX mapping System (EAM) are both CE-Marked and FDA approved medical devices. The DTA has been validated by its manufacturer only in combination with previous version of EnSite System-EnSite Precision. The aim of this study was to evaluate compatibility of DTA with EnSite X with a previously developed protocol. Methods: Three configurations were tested: 3.1. Medtronic Generator connection Box (GCB) and AmpereConnect cable; 3.2. the Medtronic GCB-E and electrogram out cable from GCB to EAM; 3.3. Direct connection of DTA to EAM using intracardiac out cable with no GCB. Results: The previously developed universal method for compatibility assessment of ablation catheters and navigation systems was used with success for assessing DTA and EnSite X EAM compatibility, with reproducible results. Accuracy of DTA visualization with different setups was evaluated with a phantom model measuring distances between DTA and reference points. DTA is compatible with EnSiteX EAM with a safety and reliability profile guaranteed, if within the described specifications. In particular, careful setup is mandatory to achieve good clinical outcomes as only setup 3.2 is viable for both NavX and Voxel Mode and demonstrated satisfactory results and accuracy. Setup 3.3 showed a significant shift immediately after catheter insertion. Catheter position was away from baseline points and the dislocation increased during the radiofrequency delivery. Conclusions: Previously developed method for compatibility assessment of ablation catheters and navigation systems has been used for a new EAM. DTA is compatible with EnSiteX EAM with proper configuration.

6.
Front Cardiovasc Med ; 9: 917218, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35837608

RESUMO

Background: New technologies for ablation procedures are often produced by different companies with no cross-compatibility out of the box. This is not a negligible clinical problem since those separately developed devices are often used together. The aim of this study was to develop a bench-testing method to assess compatibility between the DiamondTemp ablation system (DTA) and the Rhythmia electroanatomic mapping system (EAM). Methods: Different setups were tested. DTA was connected to the Rhythmia EAM using the following configurations: 3.1. An Ensite EPT GenConnect box (GCB) and Rhythmia Maestro GCB (Maestro GCB, native Rhythmia setup); 3.2. The Medtronic GCB-E and Maestro GCB; 3.3. The Medtronic GCB-E out via the Medtronic GCB-E directly to the Rhythmia at box 1 (pin A61 to A64). Results: The DTA location was represented in real-time on the Rhythmia EAM. A proper tracking of the DTA was observed in all setups tested by visual comparison of physical catheter movements and its representation on EAM. In configuration 3.1, a significant shift was observed after the first radio frequency (RF) application; however, further applications caused no further shift. In setup 3.2, no significant shift was observed. The setup 3.3 showed a massive shift in the catheter position before ablation compared to baseline points acquired using the Orion catheter as a reference. Conclusions: A universal and reproducible solution for compatibility testing between the various mapping systems and the ablation catheters has been described. DTA has been demonstrated as compatible with Rhythmia EAM with satisfactory results if a specific setup is used.

7.
Indian Pacing Electrophysiol J ; 19(6): 211-215, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31238123

RESUMO

BACKGROUND: The new version of inner lumen mapping catheter (Achieve Advance™; Medtronic, Minnesota, USA) includes a new solid core which provides improved rotational response, as compared to the current Achieve Mapping Catheter. In the present study, we sought to analyze the rate of visualisation of real-time recordings using this new device comparing it with a large cohort of patients having undergone second generation cryoballoon (CB) ablation using the previous Achieve mapping catheter. METHODS: All patients having undergone CB ablation using the Achieve Advance and the last 150 consecutive patients having undergone CB ablation using the previous Achieve were analysed. Exclusion criteria were presence of an intracavitary thrombus, uncontrolled heart failure, moderate or severe valvular disease and contraindications to general anesthesia. RESULTS: A total of 200 consecutive patients (60.1 ±â€¯9.5 years, 75% males) were evaluated (50 Achieve Advance and 150 old Achieve). Real-time recordings were significantly more prevalent in the "new Achieve Advance" population compared with the "old Achieve" group (73.5% vs 56.8%; p = 0.0001). Real-time recordings could be more frequently visualized in the "Achieve Advance" group in all veins except RIPV (LSPV: 86% vs 71.3%, p = 0.04; LIPV: 84% vs 62.7%, p = 0.005; RSPV: 78% vs 52%, p < 0.0001; RIPV: 46% vs 41.3%, p = 0.3). CONCLUSIONS: The rate of visualisation of real-time recordings is significantly higher using the new Achieve Advance if compared to the previous Achieve mapping catheter in the setting of CB ablation. Real-time recordings can be visualized in approximately 73.5% of veins with this new device.

8.
Europace ; 19(11): 1864-1873, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-27738063

RESUMO

AIMS: To investigate the clinical characteristics, prognoses, and presence of risk factors in young patients with Brugada syndrome (BS). METHODS AND RESULTS: A consecutive cohort of 128 young BS patients (≤25 years old at diagnosis) was analysed. Eighty-eight patients (69%) were asymptomatic, whereas 40 (31%) presented with clinical manifestations of BS. Markers of prognosis and risk were identified upon comparison of these two groups. A history of malignant syncope was strong predictors of ventricular arrhythmic events. Family history of sudden cardiac death (SCD) and mutations in the SCN5A gene did not associate with increased risk. Symptomatic patients presented with significantly abnormal baseline electrical characteristics when compared with the asymptomatic cohort, including spontaneous type I electrocardiograph (ECG) patterns, sinus node dysfunction (SND), first-degree atrioventricular (AV) block, and intra-ventricular conduction delay. The symptomatic group more frequently exhibited atrial arrhythmias. Electrophysiological studies resulted positive more frequently in symptomatic patients, but no risk association for future events could be determined. During the follow-up period (mean: 65 months), 10 arrhythmic events occurred in nine symptomatic patients (event rate: 4.5% per year). No events occurred in the asymptomatic group. Variables significantly associated with arrhythmic events during follow-up were presence of symptoms at diagnosis and spontaneous type I ECG. The presence of atrial arrhythmias and conduction abnormalities was also associated with the risk of arrhythmic events during follow-up. CONCLUSION: Symptomatic BS in the young age is a rare but malignant condition that can manifest with a spectrum of electrical abnormalities (i.e. SND, atrial tachycardias, AV block, and infra-nodal conduction delay) and result in the extreme cases in lethal arrhythmic events and SCD.


Assuntos
Síndrome de Brugada/complicações , Sistema de Condução Cardíaco/fisiopatologia , Potenciais de Ação , Adolescente , Adulto , Fatores Etários , Doenças Assintomáticas , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/fisiopatologia , Síndrome de Brugada/terapia , Criança , Pré-Escolar , Desfibriladores Implantáveis , Progressão da Doença , Intervalo Livre de Doença , Cardioversão Elétrica/instrumentação , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Predisposição Genética para Doença , Frequência Cardíaca , Humanos , Lactente , Estimativa de Kaplan-Meier , Masculino , Modelos de Riscos Proporcionais , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Adulto Jovem
9.
Am J Cardiol ; 111(3): 362-7, 2013 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-23206922

RESUMO

Atrial fibrillation (AF) can be the first manifestation of latent Brugada syndrome (BS). The aim of our study was to assess the prevalence of AF as the first clinical diagnosis in patients with BS and their demographic and clinical characteristics and diagnosis management in a large cohort of patients. The patient group consisted of 611 patients with BS. The data from those with a diagnosis of AF previous to the identification of BS were analyzed (n = 35). Eleven cases were unmasked after the initiation of a class I antiarrhythmic drug and one during the establishment of general anesthesia. In the remaining population, BS was diagnosed using an ajmaline test performed mainly because of younger age in patients with lone AF (n = 13), previous syncope or sudden cardiac death (n = 3), or a clinical history of sudden cardiac death in the family (n = 5). The mean patient age was 49 ± 15 years, 21 were male patients, 14 had a family history of sudden death, 15 had had previous syncope, and 4 had survived cardiac arrest. Concomitant electrical disorder was found in 13 patients. Remarkably, 21 patients had normal findings on the baseline electrocardiogram. In conclusion, AF could be one of the first clinical manifestations of latent BS in a considerable number of patients. This identification is crucial because the treatment of these patients is subject to relevant changes. The ajmaline test plays an essential role, mainly in young patients with a family history of sudden death, despite having normal findings on a baseline electrocardiogram.


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/epidemiologia , Síndrome de Brugada/tratamento farmacológico , Adulto , Fibrilação Atrial/complicações , Fibrilação Atrial/prevenção & controle , Bélgica/epidemiologia , Síndrome de Brugada/complicações , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Prognóstico , Estudos Retrospectivos , Fatores de Risco
10.
Europace ; 13(9): 1335-9, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21616943

RESUMO

AIMS: To document symptomatic episodes of palpitations with traditional methods such as24 h Holter monitoring (HM) or loop recorders remains a big challenge in clinical practice. Clinical trials with patient-activated electrocardiography (ECG) recorders show increased diagnostic yield in such patients. However, studies in the paediatric population are limited. We want to present a first experience with an event-recording system Omron HeartScan in children with symptomatic palpitations. METHODS AND RESULTS: Thirty paediatric patients (age 4-16 years) were followed with the Omron at our centre. All patients had a normal echocardiogram, a normal baseline 12-lead ECG and a normal 24 h HM. Indications with regard to monitoring were palpitations (n = 30). Two of them also had episodes of pre-syncope. The average of palpitation episodes in the past 3 months was 13.2 ± 8.3. The mean age of the study population was 9.7 ± 2.3 years [17 males (56.7 %)]. In all patients (n = 30) a diagnostic event could be recorded with the studied system. Four patients were diagnosed with supraventricular tachycardia (SVT) and underwent catheter ablation. The remaining patients (n = 26; 87%) were diagnosed with sinus tachycardia. Two patients with SVT additionally had episodes of pre-syncope. None of the patients could be diagnosed with previous 24 h HM. CONCLUSION: This event recorder has a high diagnostic yield in the childhood population. The children enjoyed the ease of using the system under daily-life conditions. In this study the system was able to record a diagnostic event in all patients with palpitations.


Assuntos
Eletrocardiografia Ambulatorial/instrumentação , Taquicardia Sinusal/diagnóstico , Taquicardia Supraventricular/diagnóstico , Adolescente , Ablação por Cateter , Criança , Pré-Escolar , Eletrocardiografia Ambulatorial/economia , Eletrocardiografia Ambulatorial/métodos , Feminino , Humanos , Masculino , Projetos Piloto , Síncope/diagnóstico , Taquicardia Sinusal/cirurgia , Taquicardia Supraventricular/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA