Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
2.
Circ Arrhythm Electrophysiol ; 17(3): e012446, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38258308

RESUMO

BACKGROUND: Antimicrobial envelopes reduce the incidence of cardiac implantable electronic device infections, but their cost restricts routine use in the United Kingdom. Risk scoring could help to identify which patients would most benefit from this technology. METHODS: A novel risk score (BLISTER [Blood results, Long procedure time, Immunosuppressed, Sixty years old (or younger), Type of procedure, Early re-intervention, Repeat procedure]) was derived from multivariate analysis of factors associated with cardiac implantable electronic device infection. Diagnostic utility was assessed against the existing PADIT score (Prior procedure, Age, Depressed renal function, Immunocompromised, Type of procedure) in both standard and high-risk external validation cohorts, and cost-utility models examined different BLISTER and PADIT score thresholds for TYRX (Medtronic; Minneapolis, MN) antimicrobial envelope allocation. RESULTS: In a derivation cohort (n=7383), cardiac implantable electronic device infection occurred in 59 individuals within 12 months of a procedure (event rate, 0.8%). In addition to the PADIT score constituents, lead extraction (hazard ratio, 3.3 [95% CI, 1.9-6.1]; P<0.0001), C-reactive protein >50 mg/L (hazard ratio, 3.0 [95% CI, 1.4-6.4]; P=0.005), reintervention within 2 years (hazard ratio, 10.1 [95% CI, 5.6-17.9]; P<0.0001), and top-quartile procedure duration (hazard ratio, 2.6 [95% CI, 1.6-4.1]; P=0.001) were independent predictors of infection. The BLISTER score demonstrated superior discriminative performance versus PADIT in the standard risk (n=2854, event rate: 0.8%, area under the curve, 0.82 versus 0.71; P=0.001) and high-risk validation cohorts (n=1961, event rate: 2.0%, area under the curve, 0.77 versus 0.69; P=0.001), and in all patients (n=12 198, event rate: 1%, area under the curve, 0.8 versus 0.75, P=0.002). In decision-analytic modeling, the optimum scenario assigned antimicrobial envelopes to patients with BLISTER scores ≥6 (10.8%), delivering a significant reduction in infections (relative risk reduction, 30%; P=0.036) within the National Institute for Health and Care Excellence cost-utility thresholds (incremental cost-effectiveness ratio, £18 446). CONCLUSIONS: The BLISTER score (https://qxmd.com/calculate/calculator_876/the-blister-score-for-cied-infection) was a valid predictor of cardiac implantable electronic device infection, and could facilitate cost-effective antimicrobial envelope allocation to high-risk patients.


Assuntos
Anti-Infecciosos , Desfibriladores Implantáveis , Cardiopatias , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Humanos , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Cardiopatias/complicações , Antibacterianos/uso terapêutico , Fatores de Risco , Eletrônica , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/prevenção & controle , Marca-Passo Artificial/efeitos adversos
3.
JACC Clin Electrophysiol ; 8(2): 225-235, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35210080

RESUMO

OBJECTIVES: The purpose of this study was to assess the performance and limitations of low-voltage zones (LVZ) localization by optimized late gadolinium enhancement (LGE) cardiac magnetic resonance (CMR) scar imaging in patients with cardiac implantable electronic devices (CIEDs). BACKGROUND: Scar evaluation by LGE-CMR can assist ventricular tachycardia (VT) ablation, but challenges with electroanatomical maps coregistration and presence of imaging artefacts from CIED limit accuracy. METHODS: A total of 10 patients underwent VT ablation and preprocedural LGE-CMR using wideband imaging. Scar was segmented from CMR pixel signal intensity maps using commercial software (ADAS-VT, Galgo Medical) with bespoke tools and compared with detailed electroanatomical maps (CARTO). Coregistration of EP and imaging-derived scar was performed using the aorta as a fiducial marker, and the impact of coregistration was determined by assessing intraobserver/interobserver variability and using computer simulations. Spatial smoothing was applied to assess correlation at different spatial resolutions and to reduce noise. RESULTS: Pixel signal intensity maps localized low-voltage zones (V <1.5 mV) with area under the receiver-operating characteristic curve: 0.82 (interquartile range [IQR]: 0.76-0.83), sensitivity 74% (IQR: 71%-77%), and specificity 78% (IQR: 73%-83%) and correlated with bipolar voltage (r = -0.57 [IQR: -0.68 to -0.42]) across patients. In simulations, small random shifts and rotations worsened LVZ localization in at least some cases. The use of the full aortic geometry ensured high reproducibility of LVZ localization (r >0.86 for area under the receiver-operating characteristic curve). Spatial smoothing improved localization of LVZ. Results for LVZ with V <0.5 mV were similar. CONCLUSIONS: In patients with CIEDs, novel wideband CMR sequences and personalized coregistration strategies can localize LVZ with good accuracy and may assist VT ablation procedures.


Assuntos
Meios de Contraste , Taquicardia Ventricular , Gadolínio , Humanos , Imageamento por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/patologia , Taquicardia Ventricular/cirurgia
4.
J Cardiovasc Electrophysiol ; 31(12): 3097-3103, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33107171

RESUMO

INTRODUCTION: The frequency of catheter ablation for atrial fibrillation (AF) has increased dramatically, stretching resources. Discharge on the same day as treatment may increase the efficiency and throughput. There are limited data regarding the safety of this strategy. METHODS: We performed a retrospective analysis of consecutive patients undergoing AF ablation in a tertiary center and in a district general hospital, and identified those discharged on the same day of treatment. The safety endpoint was any complication and/or presentation to hospital in the 48-h and at 30 days postdischarge. We performed an economic analysis to calculate potential cost saving. RESULTS: Among a total population of 2628 patients, we identified 727 subjects (61.1 ± 12.5 years, 69.6% male) undergoing day-case AF ablation. Cryoballoon technique was used in 79.2% of the day-cases, and 91.6% of the procedures were performed under conscious sedation. 1.8% (13) of the participants met the safety composite endpoint at 48-h, however only 0.7% (5) required at least 1 day of hospitalization. Bleeding or hematoma at the femoral access site (0.5%) and pericarditic chest pain (0.5%) were the main reasons for readmission. None experienced cardiac tamponade or other life-threatening complications in the 48-h postdischarge. Overall rate of complication and/or presentation to hospital at 30 days was 3.7%. Our day-case policy resulted in an annual cost-saving of approximately of £83 927 for our hospital. CONCLUSION: In this large multicentre cohort, same-day discharge in selected patients following AF ablation appears to be safe and cost-effective, with a very low rate of early readmission or post-discharge complication.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Assistência ao Convalescente , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Análise Custo-Benefício , Feminino , Humanos , Masculino , Alta do Paciente , Estudos Retrospectivos , Resultado do Tratamento
5.
Open Heart ; 7(1): e001155, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32076562

RESUMO

Objective: Catheter ablation is an important treatment for ventricular tachycardia (VT) that reduces the frequency of episodes of VT. We sought to evaluate the cost-effectiveness of catheter ablation versus antiarrhythmic drug (AAD) therapy. Methods: A decision-analytic Markov model was used to calculate the costs and health outcomes of catheter ablation or AAD treatment of VT for a hypothetical cohort of patients with ischaemic cardiomyopathy and an implantable cardioverter-defibrillator. The health states and input parameters of the model were informed by patient-reported health-related quality of life (HRQL) data using randomised clinical trial (RCT)-level evidence wherever possible. Costs were calculated from a 2018 UK perspective. Results: Catheter ablation versus AAD therapy had an incremental cost-effectiveness ratio (ICER) of £144 150 (€161 448) per quality-adjusted life-year gained, over a 5-year time horizon. This ICER was driven by small differences in patient-reported HRQL between AAD therapy and catheter ablation. However, only three of six RCTs had measured patient-reported HRQL, and when this was done, it was assessed infrequently. Using probabilistic sensitivity analyses, the likelihood of catheter ablation being cost-effective was only 11%, assuming a willingness-to-pay threshold of £30 000 used by the UK's National Institute for Health and Care Excellence. Conclusion: Catheter ablation of VT is unlikely to be cost-effective compared with AAD therapy based on the current randomised trial evidence. However, better designed studies incorporating detailed and more frequent quality of life assessments are needed to provide more robust and informed cost-effectiveness analyses.


Assuntos
Antiarrítmicos/economia , Antiarrítmicos/uso terapêutico , Cardiomiopatias/complicações , Ablação por Cateter/economia , Custos de Cuidados de Saúde , Isquemia Miocárdica/complicações , Taquicardia Ventricular/economia , Taquicardia Ventricular/terapia , Idoso , Antiarrítmicos/efeitos adversos , Cardiomiopatias/diagnóstico , Cardiomiopatias/economia , Cardiomiopatias/terapia , Ablação por Cateter/efeitos adversos , Análise Custo-Benefício , Desfibriladores Implantáveis/economia , Custos de Medicamentos , Cardioversão Elétrica/economia , Cardioversão Elétrica/instrumentação , Medicina Baseada em Evidências/economia , Feminino , Humanos , Masculino , Cadeias de Markov , Pessoa de Meia-Idade , Modelos Econômicos , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/economia , Isquemia Miocárdica/terapia , Qualidade de Vida , Ensaios Clínicos Controlados Aleatórios como Assunto/economia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Resultado do Tratamento
6.
J Cardiovasc Electrophysiol ; 30(12): 2900-2906, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31578806

RESUMO

INTRODUCTION: Implantable loop recorders (ILR) are predominantly implanted by cardiologists in the catheter laboratory. We developed a nurse-delivered service for the implantation of LINQ (Medtronic; Minnesota) ILRs in the outpatient setting. This study compared the safety and cost-effectiveness of the introduction of this nurse-delivered ILR service with contemporaneous physician-led procedures. METHODS: Consecutive patients undergoing an ILR at our institution between 1st July 2016 and 4th June 2018 were included. Data were prospectively entered into a computerized database, which was retrospectively analyzed. RESULTS: A total of 475 patients underwent ILR implantation, 271 (57%) of these were implanted by physicians in the catheter laboratory and 204 (43%) by nurses in the outpatient setting. Six complications occurred in physician-implants and two in nurse-implants (P = .3). Procedural time for physician-implants (13.4 ± 8.0 minutes) and nurse-implants (14.2 ± 10.1 minutes) were comparable (P = .98). The procedural cost was estimated as £576.02 for physician-implants against £279.95 with nurse-implants, equating to a 57.3% cost reduction. In our center, the total cost of ILR implantation in the catheter laboratory by physicians was £10 513.13 p.a. vs £6661.55 p.a. with a nurse-delivered model. When overheads for running, cleaning, and maintaining were accounted for, we estimated a saving of £68 685.75 was performed by moving to a nurse-delivered model for ILR implants. Over 133 catheter laboratory and implanting physician hours were saved and utilized for other more complex procedures. CONCLUSION: ILR implantation in the outpatient setting by suitably trained nurses is safe and leads to significant financial savings.


Assuntos
Assistência Ambulatorial/economia , Custos de Cuidados de Saúde , Monitorização Ambulatorial/economia , Monitorização Ambulatorial/enfermagem , Papel do Profissional de Enfermagem , Papel do Médico , Tecnologia de Sensoriamento Remoto/economia , Tecnologia de Sensoriamento Remoto/enfermagem , Adulto , Idoso , Competência Clínica/economia , Redução de Custos , Análise Custo-Benefício , Bases de Dados Factuais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Ambulatorial/instrumentação , Valor Preditivo dos Testes , Tecnologia de Sensoriamento Remoto/instrumentação , Estudos Retrospectivos , Fluxo de Trabalho
7.
Data Brief ; 21: 2376-2378, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30555876

RESUMO

Data presented in this article are supplementary materials to our article entitled "Catheter Ablation for Fascicular Ventricular Tachycardia: A Systematic review" (Creta et al., 2018). The current article provides additional procedural data regarding the catheter ablation for fascicular ventricular tachycardia (FVT) performed in the patients enrolled in our analysis. Furthermore, we provide data regarding the quality assessment of the studies included in our systematic review.

8.
Clin Invest Med ; 27(6): 324-44, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15675113

RESUMO

BACKGROUND: Apoptosis, the process of cell death, is a complex subject. In this review we highlight recent developments in the regulation and dysregulation of apoptosis in health and disease and summarize common laboratory techniques used to assess the process. METHODS: We accessed MEDLINE publications within the past 10 years, that reported on the clinical relevance, molecular mechanisms and laboratory assessment of apoptosis. PRINCIPAL FINDINGS: Apoptosis is a physiological event essential for normal biologic processes at all stages of life, including embryogenesis, tissue remodelling, cell turnover, reproduction and regulation of immune responses. Dysregulation of apoptosis, either excessive or inadequate, features prominently in the pathophysiology of many diseases, ranging from congenital anomalies to degenerative disorders, ischemic and reperfusion injury, chronic inflammatory or autoimmune diseases, certain infections and malignant disease. CONCLUSION: Improved understanding of the molecular mechanisms underlying apoptosis and its laboratory assessment is critical for reversing the pathophysiological processes associated with dysregulation of apoptosis.


Assuntos
Apoptose/fisiologia , Animais , Sobrevivência Celular/fisiologia , Humanos , Transdução de Sinais/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA