Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Cardiol J ; 29(2): 197-204, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-32436588

RESUMO

BACKGROUND: Performing selective coronary angiogram (CA) and percutaneous coronary intervention (PCI) post transcatheter aortic valve implantation (TAVI) may be challenging with various success rates of coronary ostia engagement. METHODS: Among all patients who underwent CA and/or PCI after TAVI from our single center TAVI registry, ostia cannulation success was reported according to the quality of ostia engagement and artery opacification, and was classified as either selective, partially selective or non-selective but sufficient for diagnosis. RESULTS: Among the 424 consecutive TAVI procedures performed at the aforementioned institution, 20 (4.7%) CA were performed in 19 (4.5%) patients at a median time of 464 days post TAVI (25-75% IQ: 213-634 days). CA were performed in 7 CoreValve, 9 Evolut R, 1 Evolut PRO and 2 Edwards Sapien 3 devices. Transradial vascular approach was attempted in 9 procedures (45%, right n = 6 and left n = 3) and was successful in 8 (40%) patients. A total of 20 left main artery ostium cannulation were attempted leading to a diagnostic CA in all of them with selective engagement in 65%. Engagement of the right coronary artery in 2 out of 15 attempted cases failed due to a low ostium in conjunction with a high implantation of a CoreValve prosthesis. 11 PCI (55% of CA) including 2 left main lesions were performed. In 4 patients (36.4% of the PCI), an extension catheter was required to engage the left main. All planned PCI were successful. CONCLUSIONS: Post TAVI CA and PCI are challenging but feasible even after supra-annular self-expandable valve implantation.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco , Angiografia Coronária , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
2.
Turk Kardiyol Dern Ars ; 48(3): 263-269, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32281955

RESUMO

OBJECTIVE: Chronic obstructive pulmonary disease (COPD) is associated with atrial fibrillation (AF) and reduced forced expiratory volume (FEV1) is an independent predictor for new onset AF. The aims of this study were (1) to analyze the atrial electromechanical delay (AEMD) and P wave dispersion which are two predictors of AF development in patients with COPD and without any cardiovascular disease, and (2) to assess the relationship of those with pulmonary functions as quantified by FEV1 measurements. METHODS: The study included 41 patients with COPD (33 male; mean age: 51 years) and 32 healthy controls. P wave dispersion was calculated as the difference between the maximum and minimum P wave duration in a 12-lead surface electrocardiography (ECG) recording. AEMD, defined as the time interval from the P wave onset on the ECG to the initiation of the late diastolic (Am) wave using a tissue Doppler examination, was measured from the lateral mitral annulus (LAEMD), septal annulus (SAEMD), and tricuspid lateral annulus (TAEMD). RESULTS: P wave dispersion was significantly longer in the COPD group than those in the controls (76±19 ms vs. 45±10 ms; p<0.001). All of the AEMD measurements demonstrated significant prolongation in patients with COPD (LAEMD: 74±9 ms vs. 64±11 ms; SAEMD: 66±10 ms vs. 57±12 ms; and TAEMD: 65±9 ms vs. 46±7 ms; p<0.001 for all). The only correlation with FEV1 was observed in the TAEMD values of the COPD group (rs: -401; p<0.009). CONCLUSION: Both P wave dispersion and AEMD parameters were significantly longer in COPD patients without any established structural or functional cardiac abnormalities, indicating an increased tendency for AF development, beginning from the initial stages of the disease.


Assuntos
Fibrilação Atrial/etiologia , Átrios do Coração/diagnóstico por imagem , Doença Pulmonar Obstrutiva Crônica/complicações , Testes de Função Respiratória/métodos , Fibrilação Atrial/fisiopatologia , Estudos de Casos e Controles , Estudos Transversais , Ecocardiografia/métodos , Ecocardiografia Doppler em Cores/métodos , Eletrocardiografia/métodos , Feminino , Volume Expiratório Forçado/fisiologia , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Doença Pulmonar Obstrutiva Crônica/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA