1.
Med Phys ; 42(2): 1080-6, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25652520

RESUMO

PURPOSE: The purpose of this study was to assess the accuracy of a Monte Carlo simulation-based method for estimating radiation dose from multidetector computed tomography (MDCT) by comparing simulated doses in ten patients to in-vivo dose measurements. METHODS: MD Anderson Cancer Center Institutional Review Board approved the acquisition of in-vivo rectal dose measurements in a pilot study of ten patients undergoing virtual colonoscopy. The dose measurements were obtained by affixing TLD capsules to the inner lumen of rectal catheters. Voxelized patient models were generated from the MDCT images of the ten patients, and the dose to the TLD for all exposures was estimated using Monte Carlo based simulations. The Monte Carlo simulation results were compared to the in-vivo dose measurements to determine accuracy. RESULTS: The calculated mean percent difference between TLD measurements and Monte Carlo simulations was -4.9% with standard deviation of 8.7% and a range of -22.7% to 5.7%. CONCLUSIONS: The results of this study demonstrate very good agreement between simulated and measured doses in-vivo. Taken together with previous validation efforts, this work demonstrates that the Monte Carlo simulation methods can provide accurate estimates of radiation dose in patients undergoing CT examinations.


Assuntos
Método de Monte Carlo , Tomografia Computadorizada Multidetectores , Humanos , Imagens de Fantasmas , Doses de Radiação , Radiometria , Reprodutibilidade dos Testes
2.
AJR Am J Roentgenol ; 202(4): 703-10, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24660695

RESUMO

OBJECTIVE: The purpose of this study was to develop a method of measuring rectal radiation dose in vivo during CT colonography (CTC) and assess the accuracy of size-specific dose estimates (SSDEs) relative to that of in vivo dose measurements. MATERIALS AND METHODS: Thermoluminescent dosimeter capsules were attached to a CTC rectal catheter to obtain four measurements of the CT radiation dose in 10 volunteers (five men and five women; age range, 23-87 years; mean age, 70.4 years). A fixed CT technique (supine and prone, 50 mAs and 120 kVp each) was used for CTC. SSDEs and percentile body habitus measurements were based on CT images and directly compared with in vivo dose measurements. RESULTS: The mean absorbed doses delivered to the rectum ranged from 8.8 to 23.6 mGy in the 10 patients, whose mean body habitus was in the 27th percentile among American adults 18-64 years old (range, 0.5-67th percentile). The mean SSDE error was 7.2% (range, 0.6-31.4%). CONCLUSION: This in vivo radiation dose measurement technique can be applied to patients undergoing CTC. Our measurements indicate that SSDEs are reasonable estimates of the rectal absorbed dose. The data obtained in this pilot study can be used as benchmarks for assessing dose estimates using other indirect methods (e.g., Monte Carlo simulations).


Assuntos
Colonografia Tomográfica Computadorizada , Doses de Radiação , Reto/efeitos da radiação , Dosimetria Termoluminescente/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Método de Monte Carlo , Projetos Piloto
3.
Med Phys ; 40(9): 091901, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24007152

RESUMO

PURPOSE: CT neuroperfusion examinations are capable of delivering high radiation dose to the skin or lens of the eyes of a patient and can possibly cause deterministic radiation injury. The purpose of this study is to: (a) estimate peak skin dose and eye lens dose from CT neuroperfusion examinations based on several voxelized adult patient models of different head size and (b) investigate how well those doses can be approximated by some commonly used CT dose metrics or tools, such as CTDIvol, American Association of Physicists in Medicine (AAPM) Report No. 111 style peak dose measurements, and the ImPACT organ dose calculator spreadsheet. METHODS: Monte Carlo simulation methods were used to estimate peak skin and eye lens dose on voxelized patient models, including GSF's Irene, Frank, Donna, and Golem, on four scanners from the major manufacturers at the widest collimation under all available tube potentials. Doses were reported on a per 100 mAs basis. CTDIvol measurements for a 16 cm CTDI phantom, AAPM Report No. 111 style peak dose measurements, and ImPACT calculations were performed for available scanners at all tube potentials. These were then compared with results from Monte Carlo simulations. RESULTS: The dose variations across the different voxelized patient models were small. Dependent on the tube potential and scanner and patient model, CTDIvol values overestimated peak skin dose by 26%-65%, and overestimated eye lens dose by 33%-106%, when compared to Monte Carlo simulations. AAPM Report No. 111 style measurements were much closer to peak skin estimates ranging from a 14% underestimate to a 33% overestimate, and with eye lens dose estimates ranging from a 9% underestimate to a 66% overestimate. The ImPACT spreadsheet overestimated eye lens dose by 2%-82% relative to voxelized model simulations. CONCLUSIONS: CTDIvol consistently overestimates dose to eye lens and skin. The ImPACT tool also overestimated dose to eye lenses. As such they are still useful as a conservative predictor of dose for CT neuroperfusion studies. AAPM Report No. 111 style measurements are a better predictor of both peak skin and eye lens dose than CTDIvol and ImPACT for the patient models used in this study. It should be remembered that both the AAPM Report No. 111 peak dose metric and CTDIvol dose metric are dose indices and were not intended to represent actual organ doses.


Assuntos
Cristalino/efeitos da radiação , Método de Monte Carlo , Órgãos em Risco/efeitos da radiação , Perfusão , Doses de Radiação , Relatório de Pesquisa , Pele/efeitos da radiação , Adulto , Encéfalo/diagnóstico por imagem , Encéfalo/efeitos da radiação , Humanos , Masculino , Pessoa de Meia-Idade , Radiometria , Sociedades Médicas , Fatores de Tempo , Tomografia Computadorizada por Raios X
4.
AJR Am J Roentgenol ; 198(2): 412-7, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22268186

RESUMO

OBJECTIVE: The purpose of our study was to accurately estimate the radiation dose to skin and the eye lens from clinical CT brain perfusion studies, investigate how well scanner output (expressed as volume CT dose index [CTDI(vol)]) matches these estimated doses, and investigate the efficacy of eye lens dose reduction techniques. MATERIALS AND METHODS: Peak skin dose and eye lens dose were estimated using Monte Carlo simulation methods on a voxelized patient model and 64-MDCT scanners from four major manufacturers. A range of clinical protocols was evaluated. CTDI(vol) for each scanner was obtained from the scanner console. Dose reduction to the eye lens was evaluated for various gantry tilt angles as well as scan locations. RESULTS: Peak skin dose and eye lens dose ranged from 81 mGy to 348 mGy, depending on the scanner and protocol used. Peak skin dose and eye lens dose were observed to be 66-79% and 59-63%, respectively, of the CTDI(vol) values reported by the scanners. The eye lens dose was significantly reduced when the eye lenses were not directly irradiated. CONCLUSION: CTDI(vol) should not be interpreted as patient dose; this study has shown it to overestimate dose to the skin or eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice. These actions should be considered when they are consistent with the clinical task and patient anatomy.


Assuntos
Encéfalo/diagnóstico por imagem , Cristalino/efeitos da radiação , Doses de Radiação , Pele/efeitos da radiação , Tomografia Computadorizada por Raios X/métodos , Protocolos Clínicos , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Lesões por Radiação/prevenção & controle , Radiometria/métodos
5.
Med Phys ; 37(4): 1816-25, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20443504

RESUMO

PURPOSE: Monte Carlo radiation transport techniques have made it possible to accurately estimate the radiation dose to radiosensitive organs in patient models from scans performed with modern multidetector row computed tomography (MDCT) scanners. However, there is considerable variation in organ doses across scanners, even when similar acquisition conditions are used. The purpose of this study was to investigate the feasibility of a technique to estimate organ doses that would be scanner independent. This was accomplished by assessing the ability of CTDIvol measurements to account for differences in MDCT scanners that lead to organ dose differences. METHODS: Monte Carlo simulations of 64-slice MDCT scanners from each of the four major manufacturers were performed. An adult female patient model from the GSF family of voxelized phantoms was used in which all ICRP Publication 103 radiosensitive organs were identified. A 120 kVp, full-body helical scan with a pitch of 1 was simulated for each scanner using similar scan protocols across scanners. From each simulated scan, the radiation dose to each organ was obtained on a per mA s basis (mGy/mA s). In addition, CTDIvol values were obtained from each scanner for the selected scan parameters. Then, to demonstrate the feasibility of generating organ dose estimates from scanner-independent coefficients, the simulated organ dose values resulting from each scanner were normalized by the CTDIvol value for those acquisition conditions. RESULTS: CTDIvol values across scanners showed considerable variation as the coefficient of variation (CoV) across scanners was 34.1%. The simulated patient scans also demonstrated considerable differences in organ dose values, which varied by up to a factor of approximately 2 between some of the scanners. The CoV across scanners for the simulated organ doses ranged from 26.7% (for the adrenals) to 37.7% (for the thyroid), with a mean CoV of 31.5% across all organs. However, when organ doses are normalized by CTDIvoI values, the differences across scanners become very small. For the CTDIvol, normalized dose values the CoVs across scanners for different organs ranged from a minimum of 2.4% (for skin tissue) to a maximum of 8.5% (for the adrenals) with a mean of 5.2%. CONCLUSIONS: This work has revealed that there is considerable variation among modern MDCT scanners in both CTDIvol and organ dose values. Because these variations are similar, CTDIvol can be used as a normalization factor with excellent results. This demonstrates the feasibility of establishing scanner-independent organ dose estimates by using CTDIvol to account for the differences between scanners.


Assuntos
Tomógrafos Computadorizados , Tomografia Computadorizada por Raios X/instrumentação , Medula Óssea/patologia , Osso e Ossos/patologia , Simulação por Computador , Desenho de Equipamento , Humanos , Modelos Teóricos , Método de Monte Carlo , Imagens de Fantasmas , Doses de Radiação , Software , Distribuição Tecidual , Tomografia Computadorizada por Raios X/métodos
6.
AJR Am J Roentgenol ; 193(5): 1340-5, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19843751

RESUMO

OBJECTIVE: The aims of this study were to estimate the dose to radiosensitive organs (glandular breast and lung) in patients of various sizes undergoing routine chest CT examinations with and without tube current modulation; to quantify the effect of tube current modulation on organ dose; and to investigate the relation between patient size and organ dose to breast and lung resulting from chest CT examinations. MATERIALS AND METHODS: Thirty voxelized models generated from images of patients were extended to include lung contours and were used to represent a cohort of women of various sizes. Monte Carlo simulation-based virtual MDCT scanners had been used in a previous study to estimate breast dose from simulations of a fixed-tube-current and a tube current-modulated chest CT examinations of each patient model. In this study, lung doses were estimated for each simulated examination, and the percentage organ dose reduction attributed to tube current modulation was correlated with patient size for both glandular breast and lung tissues. RESULTS: The average radiation dose to lung tissue from a chest CT scan obtained with fixed tube current was 23 mGy. The use of tube current modulation reduced the lung dose an average of 16%. Reductions in organ dose (up to 56% for lung) due to tube current modulation were more substantial among smaller patients than larger. For some larger patients, use of tube current modulation for chest CT resulted in an increase in organ dose to the lung as high as 33%. For chest CT, lung dose and breast dose estimates had similar correlations with patient size. On average the two organs receive approximately the same dose effects from tube current modulation. CONCLUSION: The dose to radiosensitive organs during fixed-tube-current and tube current-modulated chest CT can be estimated on the basis of patient size. Organ dose generally decreases with the use of tube current-modulated acquisition, but patient size can directly affect the dose reduction achieved.


Assuntos
Mama/efeitos da radiação , Pulmão/efeitos da radiação , Doses de Radiação , Radiometria/métodos , Tomografia Computadorizada por Raios X , Adolescente , Adulto , Idoso de 80 Anos ou mais , Simulação por Computador , Feminino , Humanos , Método de Monte Carlo , Radiografia Torácica
7.
Med Phys ; 36(6): 2154-64, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19610304

RESUMO

The purpose of this study was to present a method for generating x-ray source models for performing Monte Carlo (MC) radiation dosimetry simulations of multidetector row CT (MDCT) scanners. These so-called "equivalent" source models consist of an energy spectrum and filtration description that are generated based wholly on the measured values and can be used in place of proprietary manufacturer's data for scanner-specific MDCT MC simulations. Required measurements include the half value layers (HVL1 and HVL2) and the bowtie profile (exposure values across the fan beam) for the MDCT scanner of interest. Using these measured values, a method was described (a) to numerically construct a spectrum with the calculated HVLs approximately equal to those measured (equivalent spectrum) and then (b) to determine a filtration scheme (equivalent filter) that attenuates the equivalent spectrum in a similar fashion as the actual filtration attenuates the actual x-ray beam, as measured by the bowtie profile measurements. Using this method, two types of equivalent source models were generated: One using a spectrum based on both HVL1 and HVL2 measurements and its corresponding filtration scheme and the second consisting of a spectrum based only on the measured HVL1 and its corresponding filtration scheme. Finally, a third type of source model was built based on the spectrum and filtration data provided by the scanner's manufacturer. MC simulations using each of these three source model types were evaluated by comparing the accuracy of multiple CT dose index (CTDI) simulations to measured CTDI values for 64-slice scanners from the four major MDCT manufacturers. Comprehensive evaluations were carried out for each scanner using each kVp and bowtie filter combination available. CTDI experiments were performed for both head (16 cm in diameter) and body (32 cm in diameter) CTDI phantoms using both central and peripheral measurement positions. Both equivalent source model types result in simulations with an average root mean square (RMS) error between the measured and simulated values of approximately 5% across all scanner and bowtie filter combinations, all kVps, both phantom sizes, and both measurement positions, while data provided from the manufacturers gave an average RMS error of approximately 12% pooled across all conditions. While there was no statistically significant difference between the two types of equivalent source models, both of these model types were shown to be statistically significantly different from the source model based on manufacturer's data. These results demonstrate that an equivalent source model based only on measured values can be used in place of manufacturer's data for Monte Carlo simulations for MDCT dosimetry.


Assuntos
Algoritmos , Carga Corporal (Radioterapia) , Filtração/métodos , Modelos Biológicos , Radiometria/métodos , Tomografia Computadorizada por Raios X/métodos , Simulação por Computador , Humanos , Método de Monte Carlo , Eficiência Biológica Relativa , Espalhamento de Radiação
8.
Med Phys ; 36(3): 1025-38, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19378763

RESUMO

The larger coverage afforded by wider z-axis beams in multidetector CT (MDCT) creates larger cone angles and greater beam divergence, which results in substantial surface dose variation for helical and contiguous axial scans. This study evaluates the variation of absorbed radiation dose in both cylindrical and anthropomorphic phantoms when performing helical or contiguous axial scans. The approach used here was to perform Monte Carlo simulations of a 64 slice MDCT. Simulations were performed with different radiation profiles (simulated beam widths) for a given collimation setting (nominal beam width) and for different pitch values and tube start angles. The magnitude of variation at the surface was evaluated under four different conditions: (a) a homogeneous CTDI phantom with different combinations of pitch and simulated beam widths, (b) a heterogeneous anthropomorphic phantom with one measured beam collimation and various pitch values, (c) a homogeneous CTDI phantom with fixed beam collimation and pitch, but with different tube start angles, and (d) pitch values that should minimize variations of surface dose-evaluated for both homogeneous and heterogeneous phantoms. For the CTDI phantom simulations, peripheral dose patterns showed variation with percent ripple as high as 65% when pitch is 1.5 and simulated beam width is equal to the nominal collimation. For the anterior surface dose on an anthropomorphic phantom, the percent ripple was as high as 40% when the pitch is 1.5 and simulated beam width is equal to the measured beam width. Low pitch values were shown to cause beam overlaps which created new peaks. Different x-ray tube start angles create shifts of the peripheral dose profiles. The start angle simulations showed that for a given table position, the surface dose could vary dramatically with minimum values that were 40% of the peak when all conditions are held constant except for the start angle. The last group of simulations showed that an "ideal" pitch value can be determined which reduces surface dose variations, but this pitch value must take into account the measured beam width. These results reveal the complexity of estimating surface dose and demonstrate a range of dose variability at surface positions for both homogeneous cylindrical and heterogeneous anthropomorphic phantoms. These findings have potential implications for small-sized dosimeter measurements in phantoms, such as with TLDs or small Farmer chambers.


Assuntos
Tomografia Computadorizada por Raios X/estatística & dados numéricos , Antropometria , Fenômenos Biofísicos , Humanos , Modelos Teóricos , Método de Monte Carlo , Imagens de Fantasmas , Radiometria/instrumentação , Tomografia Computadorizada por Raios X/métodos
9.
Phys Med Biol ; 54(3): 497-512, 2009 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-19124953

RESUMO

Tube current modulation was designed to reduce radiation dose in CT imaging while maintaining overall image quality. This study aims to develop a method for evaluating the effects of tube current modulation (TCM) on organ dose in CT exams of actual patient anatomy. This method was validated by simulating a TCM and a fixed tube current chest CT exam on 30 voxelized patient models and estimating the radiation dose to each patient's glandular breast tissue. This new method for estimating organ dose was compared with other conventional estimates of dose reduction. Thirty detailed voxelized models of patient anatomy were created based on image data from female patients who had previously undergone clinically indicated CT scans including the chest area. As an indicator of patient size, the perimeter of the patient was measured on the image containing at least one nipple using a semi-automated technique. The breasts were contoured on each image set by a radiologist and glandular tissue was semi-automatically segmented from this region. Previously validated Monte Carlo models of two multidetector CT scanners were used, taking into account details about the source spectra, filtration, collimation and geometry of the scanner. TCM data were obtained from each patient's clinical scan and factored into the model to simulate the effects of TCM. For each patient model, two exams were simulated: a fixed tube current chest CT and a tube current modulated chest CT. X-ray photons were transported through the anatomy of the voxelized patient models, and radiation dose was tallied in the glandular breast tissue. The resulting doses from the tube current modulated simulations were compared to the results obtained from simulations performed using a fixed mA value. The average radiation dose to the glandular breast tissue from a fixed tube current scan across all patient models was 19 mGy. The average reduction in breast dose using the tube current modulated scan was 17%. Results were size dependent with smaller patients getting better dose reduction (up to 64% reduction) and larger patients getting a smaller reduction, and in some cases the dose actually increased when using tube current modulation (up to 41% increase). The results indicate that radiation dose to glandular breast tissue generally decreases with the use of tube current modulated CT acquisition, but that patient size (and in some cases patient positioning) may affect dose reduction.


Assuntos
Carga Corporal (Radioterapia) , Mama/fisiologia , Mamografia/métodos , Modelos Biológicos , Doses de Radiação , Radiometria/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Simulação por Computador , Feminino , Humanos , Pessoa de Meia-Idade , Modelos Estatísticos , Método de Monte Carlo , Eficiência Biológica Relativa , Adulto Jovem
10.
Radiology ; 249(1): 220-7, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18796678

RESUMO

PURPOSE: To use Monte Carlo simulations of a current-technology multidetector computed tomographic (CT) scanner to investigate fetal radiation dose resulting from an abdominal and pelvic examination for a range of actual patient anatomies that include variation in gestational age and maternal size. MATERIALS AND METHODS: Institutional review board approval was obtained for this HIPAA-compliant retrospective study. Twenty-four models of maternal and fetal anatomy were created from image data from pregnant patients who had previously undergone clinically indicated CT examination. Gestational age ranged from less than 5 weeks to 36 weeks. Simulated helical scans of the abdominal and pelvic region were performed, and a normalized dose (in milligrays per 100 mAs) was calculated for each fetus. Stepwise multiple linear regression was performed to analyze the correlation of dose with gestational age and anatomic measurements of maternal size and fetal location. Results were compared with several existing fetal dose estimation methods. RESULTS: Normalized fetal dose estimates from the Monte Carlo simulations ranged from 7.3 to 14.3 mGy/100 mAs, with an average of 10.8 mGy/100 mAs. Previous methods yielded values of 10-14 mGy/100 mAs. The correlation between gestational age and fetal dose was not significant (P = .543). Normalized fetal dose decreased linearly with increasing patient perimeter (R(2) = 0.681, P < .001), and a two-factor model with patient perimeter and fetal depth demonstrated a strong correlation with fetal dose (R(2) = 0.799, P < .002). CONCLUSION: A method for the estimation of fetal dose from models of actual patient anatomy that represented a range of gestational age and patient size was developed. Fetal dose correlated with maternal perimeter and varied more than previously recognized. This correlation improves when maternal size and fetal depth are combined.


Assuntos
Feto/efeitos da radiação , Pelve/diagnóstico por imagem , Doses de Radiação , Radiografia Abdominal , Tomografia Computadorizada por Raios X , Feminino , Idade Gestacional , Humanos , Método de Monte Carlo , Gravidez , Radiometria , Estudos Retrospectivos
11.
Acad Radiol ; 13(11): 1431-41, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17111584

RESUMO

RATIONALE AND OBJECTIVES: The American College of Radiology Imaging Network is participating in the National Lung Screening Trial, a large, multicenter, randomized controlled trial, comparing multidetector helical computed tomography (MDCT) versus chest radiography (CXR) in screening for lung cancer. Because the threshold for detection of disease is an inherent function of image quality, and consistent image quality is necessary to track changes in suspicious findings, our purpose was to develop an image quality control (QC) program across all clinical sites for both modalities. MATERIALS AND METHODS: The primary goals of the QC program include standardization of imaging protocols, certification of imaging equipment, and ongoing, periodic evaluation of the equipment calibration and image quality. Minimum standards for equipment and standardized cross-platform acquisition protocols are achieved via radiologist and physicist attestation forms and web-distributed technique charts, respectively. Imaging equipment performance standards are implemented through an initial machine certification process that includes equipment calibration. Ongoing assessment of equipment performance and calibration, as well as adherence to established imaging protocols. is accomplished via periodic submission of calibration records and phantom images. Participant-specific image acquisition parameters are entered into a web-based centralized database and variations from established protocols are automatically flagged for review. Participant radiation dose can be estimated from the image acquisition parameters applied to the imaging equipment calibration measurements. A radiologist visual review committee also evaluates participant images for diagnostic quality. Data are collected from 23 independent centers, representing 14 models of MDCT scanners from four manufacturers, and CXR systems that include film-screen, computed radiography, and direct digital radiography systems. RESULTS: Widespread imaging protocol variation in extant clinical practice-as well as variability in equipment technology, image acquisition parameters, manufacturer terminology, and user interface-have required careful standardization as a prerequisite to trial participation and ongoing image QC. Acceptable ranges for image acquisition parameters have been refined to accommodate continuously evolving equipment platforms and the scope of participant size and body habitus. CONCLUSION: Standardization of imaging protocols is a critical component of image-based clinical trials, predicated on ongoing dialogue between sites and a centralized review committee.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Desenvolvimento de Programas , Controle de Qualidade , Radiografia Torácica , Sistemas de Informação em Radiologia/normas , Tomografia Computadorizada Espiral , Inteligência Artificial , Fidelidade a Diretrizes , Humanos , Processamento de Imagem Assistida por Computador/normas , Neoplasias Pulmonares/epidemiologia , Programas de Rastreamento/normas , Variações Dependentes do Observador , Participação do Paciente , Doses de Radiação , Radiografia Torácica/normas , Avaliação da Tecnologia Biomédica , Tomografia Computadorizada Espiral/normas , Estados Unidos/epidemiologia , Interface Usuário-Computador
12.
AJR Am J Roentgenol ; 186(5): 1458-67, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16632745

RESUMO

OBJECTIVE: Discrepancy between fields of view (FOVs) in a PET/CT scanner causes a truncation artifact when imaging extends beyond the CT FOV. The purposes of this study were to evaluate the impact of this artifact on measurements of 18F-FDG activity concentrations and to assess a truncation correction algorithm. MATERIALS AND METHODS: Two phantoms and five patients were used in this study. In the first phantom, three inserts (water, air, bone equivalent) were placed in a water-filled cylinder containing 18F-FDG. In the second phantom study, a chest phantom and a 2-L bottle fitted with a bone insert were used to simulate a patient's torso and arm. Both phantoms were imaged while positioned centrally (baseline) and at the edge of the CT FOV to induce truncation. PET images were reconstructed using attenuation maps from truncated and truncation-corrected CT images. Regions of interest (ROIs) drawn on the inserts, simulated arm, and background water of the baseline truncated and truncation-corrected PET images were compared. In addition, extremity malignancies of five patients truncated on CT images were reconstructed with and without correction and the maximum standard uptake values (SUVs) of the malignancies were compared. RESULTS: Truncation artifact manifests as a rim of high activity concentration at the edge of the truncated CT image with an adjacent low-concentration region peripherally. The correction algorithm minimizes these effects. Phantom studies showed a maximum variation of -5.4% in the truncation-corrected background water image compared with the baseline image. Activity concentration in the water insert was 6.3% higher while that of air and bone inserts was similar to baseline. Extremity malignancies showed a consistent increase in the maximum SUV after truncation correction. CONCLUSION: Truncation affects measurements of 18F-FDG activity concentrations in PET/CT. A truncation-correction algorithm corrects truncation artifacts with small residual error.


Assuntos
Algoritmos , Artefatos , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas