Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Magn Reson Med ; 80(6): 2449-2463, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29756286

RESUMO

PURPOSE: To develop a fast magnetic resonance fingerprinting (MRF) method for quantitative chemical exchange saturation transfer (CEST) imaging. METHODS: We implemented a CEST-MRF method to quantify the chemical exchange rate and volume fraction of the Nα -amine protons of L-arginine (L-Arg) phantoms and the amide and semi-solid exchangeable protons of in vivo rat brain tissue. L-Arg phantoms were made with different concentrations (25-100 mM) and pH (pH 4-6). The MRF acquisition schedule varied the saturation power randomly for 30 iterations (phantom: 0-6 µT; in vivo: 0-4 µT) with a total acquisition time of ≤2 min. The signal trajectories were pattern-matched to a large dictionary of signal trajectories simulated using the Bloch-McConnell equations for different combinations of exchange rate, exchangeable proton volume fraction, and water T1 and T2 relaxation times. RESULTS: The chemical exchange rates of the Nα -amine protons of L-Arg were significantly (P < 0.0001) correlated with the rates measured with the quantitation of exchange using saturation power method. Similarly, the L-Arg concentrations determined using MRF were significantly (P < 0.0001) correlated with the known concentrations. The pH dependence of the exchange rate was well fit (R2 = 0.9186) by a base catalyzed exchange model. The amide proton exchange rate measured in rat brain cortex (34.8 ± 11.7 Hz) was in good agreement with that measured previously with the water exchange spectroscopy method (28.6 ± 7.4 Hz). The semi-solid proton volume fraction was elevated in white (12.2 ± 1.7%) compared to gray (8.1 ± 1.1%) matter brain regions in agreement with previous magnetization transfer studies. CONCLUSION: CEST-MRF provides a method for fast, quantitative CEST imaging.


Assuntos
Substância Cinzenta/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Substância Branca/diagnóstico por imagem , Algoritmos , Aminas/química , Animais , Arginina/química , Encéfalo/diagnóstico por imagem , Concentração de Íons de Hidrogênio , Aumento da Imagem/métodos , Masculino , Método de Monte Carlo , Imagens de Fantasmas , Prótons , Ratos , Ratos Wistar , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Artigo em Inglês | MEDLINE | ID: mdl-29292160

RESUMO

OBJECTIVES: Bone marrow fat is inversely correlated with bone mineral density. The aim of this study is to present a method to quantify alveolar bone marrow fat content using a 15 T magnetic resonance imaging (MRI) scanner. STUDY DESIGN: A 15 T MRI scanner with a 13-mm inner diameter loop-gap radiofrequency coil was used to scan seven 3-mm diameter alveolar bone biopsy specimens. A 3-D gradient-echo relaxation time (T1)-weighted pulse sequence was chosen to obtain images. All images were obtained with a voxel size (58 µm3) sufficient to resolve trabecular spaces. Automated volume of the bone marrow fat content and derived bone volume fraction (BV/TV) were calculated. Results were compared with actual BV/TV obtained from micro-computed tomography (CT) scans. RESULTS: Mean fat tissue volume was 20.1 ± 11%. There was a significantly strong inverse correlation between fat tissue volume and BV/TV (r = -0.68; P = .045). Furthermore, there was a strong agreement between BV/TV derived from MRI and obtained with micro-CT (interclass correlation coefficient = 0.92; P = .001). CONCLUSIONS: Bone marrow fat of small alveolar bone biopsy specimens can be quantified with sufficient spatial resolution using an ultra-high-field MRI scanner and a T1-weighted pulse sequence.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Processo Alveolar/diagnóstico por imagem , Medula Óssea/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Biópsia , Densidade Óssea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Microtomografia por Raio-X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA