1.
J Clin Monit Comput ; 36(6): 1869-1879, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35332406

RESUMO

Accurate measurement of respiratory rate (RR) in neonates is challenging due to high neonatal RR variability (RRV). There is growing evidence that RRV measurement could inform and guide neonatal care. We sought to quantify neonatal RRV during a clinical study in which we compared multiparameter continuous physiological monitoring (MCPM) devices. Measurements of capnography-recorded exhaled carbon dioxide across 60-s epochs were collected from neonates admitted to the neonatal unit at Aga Khan University-Nairobi hospital. Breaths were manually counted from capnograms and using an automated signal detection algorithm which also calculated mean and median RR for each epoch. Outcome measures were between- and within-neonate RRV, between- and within-epoch RRV, and 95% limits of agreement, bias, and root-mean-square deviation. Twenty-seven neonates were included, with 130 epochs analysed. Mean manual breath count (MBC) was 48 breaths per minute. Median RRV ranged from 11.5% (interquartile range (IQR) 6.8-18.9%) to 28.1% (IQR 23.5-36.7%). Bias and limits of agreement for MBC vs algorithm-derived breath count, MBC vs algorithm-derived median breath rate, MBC vs algorithm-derived mean breath rate were - 0.5 (- 2.7, 1.66), - 3.16 (- 12.12, 5.8), and - 3.99 (- 11.3, 3.32), respectively. The marked RRV highlights the challenge of performing accurate RR measurements in neonates. More research is required to optimize the use of RRV to improve care. When evaluating MCPM devices, accuracy thresholds should be less stringent in newborns due to increased RRV. Lastly, median RR, which discounts the impact of extreme outliers, may be more reflective of the underlying physiological control of breathing.


Assuntos
Capnografia , Taxa Respiratória , Recém-Nascido , Humanos , Taxa Respiratória/fisiologia , Quênia , Monitorização Fisiológica , Respiração
2.
BMJ Open ; 12(1): e053486, 2022 01 11.
Artigo em Inglês | MEDLINE | ID: mdl-35017248

RESUMO

OBJECTIVE: To assess the feasibility, usability and acceptability of two non-invasive, multiparameter, continuous physiological monitoring (MCPM) technologies for use in neonates within a resource-constrained healthcare setting in sub-Saharan Africa. DESIGN: A qualitative study using in-depth interviews and direct observations to describe healthcare professional and caregiver perspectives and experiences with investigational MCPM technologies from EarlySense and Sibel compared with selected reference technologies. SETTING: Pumwani Maternity Hospital is a public, high-volume, tertiary hospital in Nairobi, Kenya. PARTICIPANTS: In-depth interviews were conducted with five healthcare administrators, 12 healthcare providers and 10 caregivers. Direct observations were made of healthcare providers using the technologies on 12 neonates overall. RESULTS: Design factors like non-invasiveness, portability, ease-of-use and ability to measure multiple vital signs concurrently emerged as key themes supporting the usability and acceptability of the investigational technologies. However, respondents also reported feasibility challenges to implementation, including overcrowding in the neonatal unit, lack of reliable access to electricity and computers, and concerns about cost and maintenance needs. To improve acceptability, respondents highlighted the need for adequate staffing to appropriately engage caregivers and dispel misconceptions about the technologies. CONCLUSION: Study participants were positive about the usefulness of the investigational technologies to strengthen clinical care quality and identification of at-risk neonates for better access to timely interventions. These technologies have the potential to improve equity of access to appropriate healthcare services and neonatal outcomes in sub-Saharan African healthcare facilities. However, health system strengthening is also critical to support sustainable uptake of technologies into routine care. TRIAL REGISTRATION NUMBER: NCT03920761.


Assuntos
Centros de Atenção Terciária , Estudos de Viabilidade , Feminino , Humanos , Recém-Nascido , Quênia , Monitorização Fisiológica , Gravidez , Pesquisa Qualitativa
3.
J Med Internet Res ; 23(10): e29755, 2021 10 28.
Artigo em Inglês | MEDLINE | ID: mdl-34709194

RESUMO

BACKGROUND: Continuous physiological monitoring technologies are important for strengthening hospital care for neonates, particularly in resource-constrained settings, and understanding user perspectives is critical for informing medical technology design, development, and optimization. OBJECTIVE: This study aims to assess the feasibility, usability, and acceptability of 2 noninvasive, multiparameter, continuous physiological monitoring technologies for use in neonates in an African health care setting. METHODS: We assessed 2 investigational technologies from EarlySense and Sibel, compared with the reference Masimo Rad-97 technology through in-depth interviews and direct observations. A purposive sample of health care administrators, health care providers, and caregivers at Aga Khan University Hospital, a tertiary, private hospital in Nairobi, Kenya, were included. Data were analyzed using a thematic approach in NVivo 12 software. RESULTS: Between July and August 2020, we interviewed 12 health care providers, 5 health care administrators, and 10 caregivers and observed the monitoring of 12 neonates. Staffing and maintenance of training in neonatal units are important feasibility considerations, and simple training requirements support the feasibility of the investigational technologies. Key usability characteristics included ease of use, wireless features, and reduced number of attachments connecting the neonate to the monitoring technology, which health care providers considered to increase the efficiency of care. The main factors supporting acceptability included caregiver-highlighted perceptions of neonate comfort and health care respondent technology familiarity. Concerns about the side effects of wireless connections, electromagnetic fields, and mistrust of unfamiliar technologies have emerged as possible acceptability barriers to investigational technologies. CONCLUSIONS: Overall, respondents considered the investigational technologies feasible, usable, and acceptable for the care of neonates at this health care facility. Our findings highlight the potential of different multiparameter continuous physiological monitoring technologies for use in different neonatal care settings. Simple and user-friendly technologies may help to bridge gaps in current care where there are many neonates; however, challenges in maintaining training and ensuring feasibility within resource-constrained health care settings warrant further research. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR2-10.1136/bmjopen-2019-035184.


Assuntos
Cuidadores , Pessoal de Saúde , Estudos de Viabilidade , Hospitais Privados , Humanos , Recém-Nascido , Quênia , Monitorização Fisiológica , Tecnologia , Centros de Atenção Terciária
4.
JMIR Mhealth Uhealth ; 6(7): e153, 2018 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-30054263

RESUMO

BACKGROUND: Limited evidence exists on the value for money of mHealth information programs in low resource settings. OBJECTIVE: This study sought to model the incremental cost-effectiveness of gradually scaling up text messaging services to pregnant women throughout Gauteng province, South Africa from 2012 to 2017. METHODS: Data collection occurred as part of a retrospective study in 6 health centers in Gauteng province. Stage-based short message service (SMS) text messages on maternal health were sent to pregnant women twice per week during pregnancy and continued until the infant's first birthday. Program costs, incremental costs to users, and the health system costs for these women were measured along with changes in the utilization of antenatal care visits and childhood immunizations and compared with those from a control group of pregnant women who received no SMS text messages. Incremental changes in utilization were entered into the Lives Saved Tool and used to forecast lives saved and disability adjusted life years (DALYs) averted by scaling up program activities over 5 years to reach 60% of pregnant women across Gauteng province. Uncertainty was characterized using one-way and probabilistic uncertainty analyses. RESULTS: Five-year program costs were estimated to be US $1.2 million, 17% of which were incurred by costs on program development and 31% on SMS text message delivery costs. Costs to users were US $1.66 to attend clinic-based services, nearly 90% of which was attributed to wages lost. Costs to the health system included provider time costs to register users (US $0.08) and to provide antenatal care (US $4.36) and postnatal care (US $3.08) services. Incremental costs per DALY averted from a societal perspective ranged from US $1985 in the first year of implementation to US $200 in the 5th year. At a willingness-to-pay threshold of US $2000, the project had a 40% probability of being cost-effective in year 1 versus 100% in all years thereafter. CONCLUSIONS: Study findings suggest that delivering SMS text messages on maternal health information to pregnant and postpartum women may be a cost-effective strategy for bolstering antenatal care and childhood immunizations, even at very small margins of coverage increases. Primary data obtained prospectively as part of more rigorous study designs are needed to validate modeled results.

SELEÇÃO DE REFERÊNCIAS