Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Diabetes Ther ; 14(3): 553-567, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36732434

RESUMO

INTRODUCTION: Cardiovascular disease (CVD) is the leading cause of mortality in type 1 diabetes (T1D). However, there is a need for daily practice tools for identifying those more prone to suffer from these events. We aimed to assess the relationships between nuclear magnetic resonance (1H NMR)-based lipidomic analysis and several CVD risk variables (including preclinical carotid atherosclerosis) in individuals with T1D at high risk. METHODS: We included patients with T1D without CVD, with at least one of the following: age ≥ 40 years, diabetic kidney disease, or ≥ 10 years of evolution with another risk factor. The presence of plaque (intima-media thickness > 1.5 mm) was determined by standardized ultrasonography protocol. Lipidomic analysis was performed by 1H NMR. Bivariate and multivariate-adjusted differences in 1H NMR lipidomics were evaluated. RESULTS: We included n = 131 participants (49.6% female, age 46.4 ± 10.3 years, diabetes duration 27.0 ± 9.5 years, 47.3% on statins). Carotid plaques were present in 28.2% of the individuals (n = 12, with ≥ 3 plaques). Glucose (HbA1c), anthropometric (body mass index and waist circumference), and insulin resistance-related (fatty liver index and estimated glucose disposal rate) variables were those most associated with 1H NMR-derived lipidomic analysis (p < 0.01 for all). Regarding preclinical atherosclerosis, sphingomyelin was independently associated with carotid plaque presence (for 0.1 mmol/L increase, OR 0.50 [0.28-0.86]; p = 0.013), even after adjusting for age, sex, hypertension, statin use, mean 5-year HbA1c and diabetes duration. Furthermore, linoleic acid and ω-6 fatty acids remained independently associated with higher plaque burden (≥ 3 plaques) in multivariate models (0.17 [0.03-0.93] and 0.27 [0.07-0.97], respectively; p < 0.05 for both). CONCLUSION: In our preliminary study of individuals with T1D at high risk, several 1H NMR-derived lipidomic parameters were independently associated with preclinical atherosclerosis. Specifically, ω-6 fatty acids and linoleic acid seem promising for identifying those with higher plaque burden.

2.
Diabetes Res Clin Pract ; 171: 108548, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33238177

RESUMO

AIMS: Evaluate the role of plasma metabolomics in atherosclerosis according to the presence of type 1 diabetes (T1D) or previous preeclampsia. METHODS: We recruited 105 women without cardiovascular disease and last pregnancy ≥5 years previously, divided according to the presence of T1D or previous preeclampsia. Preclinical atherosclerosis was defined as the presence of carotid plaque (intima-media thickness ≥1.5 mm) assessed by ultrasonography. Metabolomics were evaluated by nuclear magnetic resonance (NMR). Bivariate and multivariate-adjusted differences in NMR-metabolomics were evaluated. RESULTS: The participants were 44.9 ± 8.1 years-old; 20% harbored plaques. There were significant differences in lipidic-, energetic- and nitrogen-related metabolites according to the presence of T1D/preeclampsia (p < 0.05). In multivariate-adjusted models (by age, statins, blood pressure and T1D/preeclampsia), only lipidomic-related metabolites were associated with atherosclerosis in the whole sample. However, stronger associations were observed in women with previous preeclampsia (vs. without; per 0.5 mmol/L increments); phosphatidylcholine, OR 4.08 (1.32-27.22); free cholesterol, 5.18 (1.22-21.97); saturated fatty acids, OR 2.99 (1.37-6.48); w-7, OR 2.29 (1.15-4.56); and w-9 fatty acids, OR 1.49 (1.00-2.23). CONCLUSIONS: NMR-metabolomics showed a differential pattern according to the presence of T1D/preeclampsia in relation to preclinical atherosclerosis. Since most of these metabolites mirror lifestyle factors, they could help tailor dietetic advice in high-risk women.


Assuntos
Aterosclerose/diagnóstico , Diabetes Mellitus Tipo 1/complicações , Espectroscopia de Ressonância Magnética/métodos , Metabolômica/métodos , Placa Aterosclerótica/diagnóstico , Pré-Eclâmpsia/diagnóstico , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/diagnóstico por imagem , Gravidez , Fatores de Risco
3.
Endocrinol Diabetes Nutr (Engl Ed) ; 66(9): 534-539, 2019 Nov.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-31133475

RESUMO

OBJECTIVE: Less than one third of patients with type 1 diabetes mellitus (T1DM) achieve the cut-off value proposed as good metabolic control by most guidelines, HbA1c<7%. However, HbA1c reductions and prevention of severe hypoglycemia (SH) have shown clinically relevant benefits. The study objective therefore was to assess the effectiveness of continuous subcutaneous insulin infusion (CSII) therapy at 5 years of follow-up in a cohort of patients attending a specialized unit using HbA1c reduction and abscence of SH as combined goals. METHODS: A retrospective, observational study on 178 patients with T1DM who started CSII treatment at Hospital Clinic of Barcelona between 2003 and 2008. HbA1c levels at baseline and after 5 years of treatment with CSII and presence or absence of SH were recorded. The combined variables calculated included: a) HbA1c reduction by≥0.5 points and absence of SH in the last 2 years; b) HbA1c at 5 years<7.5% and no SH in the last 2 years; c) HbA1c<8.5% and no HG in the last 2 years, and d) HbA1c reduction by≥0.5 points and/or HbA1c<7.5% at 5 years with no SH in the last 2 years of follow-up. RESULTS: Twenty-seven of the 178 patients were excluded due to loss to follow-up or CSII discontinuation. A total of 151 patients (aged 37.4±10.5 years, 64% women, diabetes duration of 19.2±10.7 years) were therefore analyzed. The 2 main reasons for starting CSII were suboptimal metabolic control (60.9%) and severe hypoglycemia/hypoglycemia unawareness (28.5%). HbA1c levels in the total cohort and in patients with suboptimal metabolic control were 8.0±1.2 and 8.4±1.1% at CSII start and 7.8±1.2 and 8.0±1.3% at 5 years of treatment (P=.104 and P=.016) respectively. In the overall cohort, 55.5% of patients achieved at 5 years the combined goal of HbA1c<7.5% and/or HbA1c reductions≥0.5% without SH. CONCLUSIONS: After 5 years of CSII therapy, more than half of the patients achieved the combined goal of significant HbA1c reduction and absence of SH. The use of combined goals offers the opportunity to assess the effectiveness of T1DM treatment from a clinically more meaningful point of view.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas/análise , Hipoglicemia/prevenção & controle , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Adulto , Diabetes Mellitus Tipo 1/sangue , Feminino , Humanos , Bombas de Infusão Implantáveis , Masculino , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
4.
Endocrinol Diabetes Nutr (Engl Ed) ; 65(7): 380-386, 2018.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-29789227

RESUMO

OBJECTIVE: To compare the cost-effectiveness of sensor-augmented pump therapy (SAP) [continuous subcutaneous insulin infusion (CSII) plus real-time continuous glucose monitoring (RT-CGM)] with low glucose suspend (MiniMed™ Veo™) and CSII alone in patients with type 1 diabetes mellitus (T1DM) at high risk of hypoglycemia in Spain. METHODS: The IQVIA CORE Diabetes Model was used to estimate healthcare outcomes as life-years gained (LYGs) and quality-adjusted life years (QALYs), and to project lifetime costs. Information about efficacy, resource utilization, and unit costs (€2016) was taken from published sources and validated by an expert panel. Analyses were performed from both the Spanish National Health System (NHS) perspective and the societal perspective. RESULTS: From the NHS perspective, SAP with low glucose suspend was associated to a €47,665 increase in direct healthcare costs and to increases of 0.19 LYGs and 1.88 QALYs, both discounted, which resulted in an incremental cost-effectiveness ratio (ICER) of €25,394/QALY. From the societal perspective, SAP with low glucose suspend increased total costs (including direct and indirect healthcare costs) by €41,036, with a resultant ICER of €21,862/QALY. Considering the willingness-to-pay threshold of €30,000/QALY in Spain, SAP with low glucose suspend represents a cost-effective option from both the NHS and societal perspectives. Sensitivity analyses confirmed the robustness of the model. CONCLUSIONS: From both the Spanish NHS perspective and the societal perspective, SAP with low glucose suspend is a cost-effective option for the treatment of T1DM patients at high risk of hypoglycemia.


Assuntos
Automonitorização da Glicemia/economia , Análise Custo-Benefício , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemia/prevenção & controle , Sistemas de Infusão de Insulina/economia , Adolescente , Diabetes Mellitus Tipo 1/complicações , Feminino , Humanos , Hipoglicemia/sangue , Hipoglicemia/epidemiologia , Hipoglicemia/etiologia , Masculino , Medição de Risco , Espanha
6.
Endocrinol Diabetes Nutr ; 64(7): 377-383, 2017.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-28745609

RESUMO

OBJECTIVE: Hypoglycemia is one of the most common complications to achieve a good metabolic control, and has been listed by several scientific associations as a common indication to start treatment with continuous subcutaneous insulin infusion (CSII). Use of CSII is still residual in Spain as compared to neighbouring countries, and cost of acquisition cost is one of the main reasons. This study estimates the budget impact of treatment with CSII, as compared to multiple daily insulin injections, of patients with type 1 diabetes mellitus who experience recurrent severe hypoglycemia episodes from the National Healthcare System perspective. METHODS: Budget impact was based on a retrospective, observational study evaluating the efficacy of CSII in patients with type 1 diabetes mellitus conducted at Hospital Clínic i Universitari in Barcelona, where one of the main indications for switching to CSII were recurrent severe hypoglycemia episodes. The mean number of annual episodes was 1.33 in the two years prior to CSII start and 0.08 in the last two years of follow up (p=0.003). Costs of treatment and major hypoglycemic events over a four-year period were considered. Costs were taken from different Spanish data sources and expressed in € of 2016. RESULTS: Treatment with CSII increased costs by €9,509 per patient as compared to multiple daily insulin injections (€11,902-€2,393). Cost associated to severe hypoglycemic events decreased by €19,330 per patient treated with CSIII (€1,371-€20,701). Results suggest mean total savings of €9,821 per patient during the four-year study period. CONCLUSION: The higher costs associated to CSII therapy may be totally offset by the severe hypoglycemic events prevented.


Assuntos
Orçamentos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Custos de Medicamentos/estatística & dados numéricos , Hipoglicemia/induzido quimicamente , Hipoglicemiantes/administração & dosagem , Infusões Subcutâneas/economia , Sistemas de Infusão de Insulina/economia , Programas Nacionais de Saúde/economia , Adulto , Redução de Custos , Efeitos Psicossociais da Doença , Análise Custo-Benefício , Custos e Análise de Custo , Diabetes Mellitus Tipo 1/sangue , Feminino , Hemoglobinas Glicadas/análise , Custos de Cuidados de Saúde/estatística & dados numéricos , Humanos , Hipoglicemia/economia , Hipoglicemia/epidemiologia , Hipoglicemia/prevenção & controle , Hipoglicemiantes/efeitos adversos , Injeções Subcutâneas/economia , Masculino , Pessoa de Meia-Idade , Estudos Observacionais como Assunto , Recidiva , Estudos Retrospectivos , Espanha/epidemiologia
7.
J Diabetes Sci Technol ; 11(6): 1089-1095, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28633537

RESUMO

BACKGROUND: Closed-loop (CL) systems aims to outperform usual treatments in blood glucose control and continuous glucose monitors (CGM) are a key component in such systems. Meals represents one of the main disturbances in blood glucose control, and postprandial period (PP) is a challenging situation for both CL system and CGM accuracy. METHODS: We performed an extensive analysis of sensor's performance by numerical accuracy and precision during PP, as well as its influence in blood glucose control under CL therapy. RESULTS: During PP the mean absolute relative difference (MARD) for both sensors presented lower accuracy in the hypoglycemic range (19.4 ± 12.8%) than in other ranges (12.2 ± 8.6% in euglycemic range and 9.3 ± 9.3% in hyperglycemic range). The overall MARD was 12.1 ± 8.2%. We have also observed lower MARD for rates of change between 0 and 2 mg/dl. In CL therapy, the 10 trials with the best sensor spent less time in hypoglycemia (PG < 70 mg/dl) than the 10 trials with the worst sensors (2 ± 7 minutes vs 32 ± 38 minutes, respectively). CONCLUSIONS: In terms of accuracy, our results resemble to previously reported. Furthermore, our results showed that sensors with the lowest MARD spent less time in hypoglycemic range, indicating that the performance of CL algorithm to control PP was related to sensor accuracy.


Assuntos
Automonitorização da Glicemia , Glicemia/efeitos dos fármacos , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Período Pós-Prandial , Adulto , Algoritmos , Biomarcadores/sangue , Glicemia/metabolismo , Automonitorização da Glicemia/instrumentação , Diabetes Mellitus Tipo 1/sangue , Feminino , Humanos , Hipoglicemia/sangue , Hipoglicemia/induzido quimicamente , Hipoglicemia/diagnóstico , Hipoglicemiantes/efeitos adversos , Insulina/efeitos adversos , Sistemas de Infusão de Insulina/efeitos adversos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Fatores de Tempo , Transdutores , Resultado do Tratamento
8.
Endocrinol Nutr ; 62(8): 384-90, 2015 Oct.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-26391507

RESUMO

OBJECTIVES: The self-determination of blood glucose is relevant for diabetes mellitus (DM) insulin-treated patients. The use of glucometers with advanced features and measuring glycated haemoglobin (HbA1c) may help improve metabolic control. The main objective of this study was to determine the percentage of insulin treated patients who reduced HbA1c by at least 0.4% after 6 months of using Contour and A1CNow+. MATERIALS AND METHODS: Observational, prospective, multicentre study in adult DM insulin treated patients, with HbA1c> 8%. RESULTS: Of the 454 recruited patients analysed, a total of 333 were evaluable. After 6 months the HbA1c decreased (P<.05) in both groups [-0.89 (95% CI -1.01 to -0.76) and -0.98 (95% CI: -1.21 to -0.76), in type 1 and 2 DM, respectively]. An HbA1c reduction of 0.4% was observed in 73% of patients after 6 months of device use. A decrease in the number of patients with HbA1c > 8% was observed, with this reaching: 41% for all, 45% in type 1 DM, and 25% in type 2 DM. In the glycaemic profile, a reduction (P<.05) was observed in pre- and post-prandial glycaemia in both groups (-20.7±36.4 and -37.1±47.1mg/dL, respectively), with 23% pre-prandial glucose < 130mg/dL and post-prandial < 180mg/dL CONCLUSION: The use of glucometers with advanced features, and measuring glycated haemoglobin (HbA1c) may help improve metabolic control and to monitor insulin treated DM patients more closely.


Assuntos
Automonitorização da Glicemia/instrumentação , Glicemia/análise , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 2/sangue , Hemoglobinas Glicadas/análise , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Adulto , Consumo de Bebidas Alcoólicas/epidemiologia , Automonitorização da Glicemia/métodos , Complicações do Diabetes/epidemiologia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 2/tratamento farmacológico , Jejum/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade/epidemiologia , Período Pós-Prandial , Estudos Prospectivos , Fumar/epidemiologia , Resultado do Tratamento , Adulto Jovem
9.
Endocrinol Nutr ; 61(6): 318-22, 2014.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-24533929

RESUMO

BACKGROUND AND OBJECTIVE: Patients with type 1 diabetes (T1DM) treated with continuous subcutaneous insulin infusion (CSII) have available several specific features of these devices. The aim of this study was to evaluate the relationship between real use of them and the degree of glycemic control in patients using this therapy. PATIENTS AND METHODS: Forty-four T1DM patients on CSII therapy with or without real-time continuous glucose monitoring (CGM) were included. Data from 14 consecutive days were retrospectively collected using the therapy management software CareLink Personal/Pro(®) and HbA1c measurement performed at that period. The relationship between the frequency of usie of specific features of insulin pumps (non-sensor augmented or sensor-augmented) and glycemic control was analyzed. RESULTS: Mean HbA1c in the group was 7.5 ± .8%. Mean daily number of boluses administered was 5.1 ± 1.8, with 75.4% of them being bolus wizards (BW). Daily number of boluses was significantly greater in patients with HbA1c <7.5% than in those with HbA1c>7.5% (5.3 ± 1.6 vs. 4.3 ± 1.6, P=.056). There was a trend to greater use of BW in patients with better control (82.8 ± 21.4% vs. 69.9 ± 29.1%, P=.106). HbA1c was lower in patients using CGM (n=8) as compared to those not using sensor-augmented pumps (7.6 ± .8 vs 7.1 ± .7, P=.067), but the difference was not statistically significant. CONCLUSIONS: More frequent use of BW appears to be associated to better metabolic control in patients with T1DM using pump therapy. In standard clinical practice, augmentation of insulin pump with CGM may be associated to improved glycemic control.


Assuntos
Automonitorização da Glicemia/estatística & dados numéricos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Software , Adulto , Algoritmos , Glicemia/análise , Automonitorização da Glicemia/instrumentação , Sistemas Computacionais , Diabetes Mellitus Tipo 1/sangue , Relação Dose-Resposta a Droga , Desenho de Equipamento , Feminino , Hemoglobinas Glicadas/análise , Humanos , Bombas de Infusão Implantáveis , Infusões Subcutâneas , Insulina/uso terapêutico , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Design de Software , Resultado do Tratamento , Interface Usuário-Computador
10.
Rev Esp Cardiol ; 57(6): 577-80, 2004 Jun.
Artigo em Espanhol | MEDLINE | ID: mdl-15225505

RESUMO

Coronary risk in patients with type 2 diabetes mellitus can be calculated using population-based scores or diabetes-specific scores. Our objective was to compare the results with both scores in a group of patients with type 2 diabetes and no history of cardiovascular disease. We analyzed the results for 101 patients aged 40 to 65 years with type 2 diabetes and no prior cardiovascular disease. Two scales were used, one based on the general population (Framingham function adapted from the REGICOR study), and the other based on the population with type 2 diabetes mellitus (UKPDS risk engine). The average 10-year likelihood of coronary events was 5.8 (2.5)% and 15.7 (8.4)% for the REGICOR risk score and the UKPDS risk score, respectively (P<.001), with a Pearson correlation coefficient of 0.525 (P<.01). Risk was higher in men (19.2 [8.7]% based on the UKPDS score, and 5.6 [2.8]% based on the REGICOR score, P<.001). The figures for women were 11.3 [5.9]% and 5.9 [2.1]% with the UKPDS and REGICOR scores, respectively (P<.001). Our results suggest that substantially different findings are obtained when general population-based scores or specific scores are used to assess cardiovascular risk in subjects with type 2 diabetes.


Assuntos
Doença das Coronárias/etiologia , Diabetes Mellitus Tipo 2/complicações , Indicadores Básicos de Saúde , Adulto , Idoso , Doença das Coronárias/prevenção & controle , Feminino , Humanos , Funções Verossimilhança , Masculino , Pessoa de Meia-Idade , Medição de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA