Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Int J Radiat Oncol Biol Phys ; 98(3): 691-698, 2017 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-28581411

RESUMO

PURPOSE: To report an assessment of in-house software, Verifier, developed to improve efficacy and efficiency of the radiation therapy (RT) treatment planning process and quality control review (QCR). METHODS AND MATERIALS: Radiation therapy plan parameters retrieved from our treatment planning database are used by automated tests to give 75 types of warnings, such as prescription and plan discrepancies. The software is continuously updated on the basis of new issues, ideas, and planning policies. Verifier was retrospectively assessed (2007-2015) by examining impact on treatment plan revisions, frequency of quality improvement incident reports of avoidable RT plan-related safety events, unaddressed issues, and staff efficiency. RESULTS: Plan revisions for specific issues declined dramatically in response to implementation of corresponding Verifier tests. Between 2012 and 2015 our institution's total rate of plan revisions dropped from 18.0% to 11.2%. Between 2008 and 2015 specific tests were added to Verifier while the rate of corresponding avoidable safety events was reduced from 0.34% to 0.00% over the same period. Simulations suggest Verifier saves approximately 2 to 5 minutes per QCR. CONCLUSIONS: The decrease in quantifiable metrics of plan revisions and incident reports suggests automatic RT plan-checking software enhances patient safety and clinical efficiency. Although only modest time savings may be gained using Verifier for the QCR itself, the greater impact on efficiency is through avoiding late-stage plan modifications and improving documentation via automation. We encourage other institutions to consider working toward adding similar technologies to enhance their RT quality assurance programs.


Assuntos
Segurança do Paciente , Melhoria de Qualidade , Planejamento da Radioterapia Assistida por Computador/métodos , Software , Boston , Humanos , Segurança do Paciente/estatística & dados numéricos , Garantia da Qualidade dos Cuidados de Saúde/métodos , Radioterapia (Especialidade) , Planejamento da Radioterapia Assistida por Computador/normas , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos , Estudos Retrospectivos , Gestão de Riscos/estatística & dados numéricos , Treinamento por Simulação/métodos , Fatores de Tempo , Interface Usuário-Computador
2.
Int J Radiat Oncol Biol Phys ; 81(4): e673-9, 2011 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-21669503

RESUMO

PURPOSE: Technological advances in radiation therapy (RT) delivery have the potential to reduce errors via increased automation and built-in quality assurance (QA) safeguards, yet may also introduce new types of errors. Intensity-modulated RT (IMRT) is an increasingly used technology that is more technically complex than three-dimensional (3D)-conformal RT and conventional RT. We determined the rate of reported errors in RT delivery among IMRT and 3D/conventional RT treatments and characterized the errors associated with the respective techniques to improve existing QA processes. METHODS AND MATERIALS: All errors in external beam RT delivery were prospectively recorded via a nonpunitive error-reporting system at Brigham & Women's Hospital/Dana Farber Cancer Institute. Errors are defined as any unplanned deviation from the intended RT treatment and are reviewed during monthly departmental quality improvement meetings. We analyzed all reported errors since the routine use of IMRT in our department, from January 2004 to July 2009. Fisher's exact test was used to determine the association between treatment technique (IMRT vs. 3D/conventional) and specific error types. Effect estimates were computed using logistic regression. RESULTS: There were 155 errors in RT delivery among 241,546 fractions (0.06%), and none were clinically significant. IMRT was commonly associated with errors in machine parameters (nine of 19 errors) and data entry and interpretation (six of 19 errors). IMRT was associated with a lower rate of reported errors compared with 3D/conventional RT (0.03% vs. 0.07%, p = 0.001) and specifically fewer accessory errors (odds ratio, 0.11; 95% confidence interval, 0.01-0.78) and setup errors (odds ratio, 0.24; 95% confidence interval, 0.08-0.79). CONCLUSIONS: The rate of errors in RT delivery is low. The types of errors differ significantly between IMRT and 3D/conventional RT, suggesting that QA processes must be uniquely adapted for each technique. There was a lower error rate with IMRT compared with 3D/conventional RT, highlighting the need for sustained vigilance against errors common to more traditional treatment techniques.


Assuntos
Erros Médicos/estatística & dados numéricos , Radioterapia/métodos , Boston , Institutos de Câncer/estatística & dados numéricos , Intervalos de Confiança , Humanos , Modelos Logísticos , Razão de Chances , Segurança do Paciente , Garantia da Qualidade dos Cuidados de Saúde/normas , Controle de Qualidade , Radioterapia/normas , Erros de Configuração em Radioterapia/estatística & dados numéricos , Radioterapia Conformacional/estatística & dados numéricos , Radioterapia de Intensidade Modulada/efeitos adversos , Radioterapia de Intensidade Modulada/métodos , Radioterapia de Intensidade Modulada/estatística & dados numéricos
3.
J Appl Clin Med Phys ; 10(1): 80-89, 2009 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-19223833

RESUMO

Dental restorations, fixed prosthodontics, and implants affect dose distribution in head and neck radiation therapy due to the high atomic number of the materials utilized. The backscatter of electrons from metallic materials due to the impinging treatment x-ray results in localized dose enhancements. These dose enhancements cause localized mucositis in patients who have dental work, a significant clinical complication. We investigated the backscatter effect of 23 configurations of dental work using the EGS4nrc Monte Carlo (MC) simulation system. We found that all-metal fixed partial dentures caused the highest amount of dose enhancement--up to 33%--while amalgam restorations did not cause a significant amount. Restorations with a ceramic veneer caused up to 8% enhancement. Between 3 mm and 5 mm of water-equivalent material almost completely absorbed the backscatter. MC simulations provide an accurate estimate of backscatter dose, and may provide patient-specific estimates in future.


Assuntos
Restauração Dentária Permanente , Neoplasias de Cabeça e Pescoço/radioterapia , Método de Monte Carlo , Amálgama Dentário/efeitos da radiação , Materiais Dentários/efeitos da radiação , Humanos , Próteses e Implantes , Dosagem Radioterapêutica
4.
Med Dosim ; 32(3): 151-6, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17707193

RESUMO

Air-filled intrarectal balloons can be used to localize and immobilize the prostate for radiation therapy, allowing dose escalation to the prostate and reducing the probability of radiation proctitis, but also introducing potentially significant heterogeneity. We compare the Eclipse treatment planning system (TPS) with Monte Carlo (MC) simulations for 5 patients to assess how well a conventional TPS includes the effect of the balloon on doses near the rectum. The MC results show that, for a 27-Gy prescription to the 95% isodose line, Eclipse overestimates the volume of the rectum receiving more than 26 Gy (96%) by 2 approximately 10 cc and the volume of the rectum receiving between 12 approximately 15 Gy by 10 approximately 20 cc. Differential dose volume histograms are also computed and compared for individual fields in the anterior expansion of the rectum, and the TPS is again shown to predict higher mean dose in the region by 0.3 approximately 1.0 Gy.


Assuntos
Método de Monte Carlo , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador , Reto/efeitos da radiação , Humanos , Masculino , Doses de Radiação
5.
Med Phys ; 34(4): 1266-73, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17500458

RESUMO

This work is intended to investigate the application and accuracy of micro-MOSFET for superficial dose measurement under clinically used MV x-ray beams. Dose response of micro-MOSFET in the build-up region and on surface under MV x-ray beams were measured and compared to Monte Carlo calculations. First, percentage-depth-doses were measured with micro-MOSFET under 6 and 10 MV beams of normal incidence onto a flat solid water phantom. Micro-MOSFET data were compared with the measurements from a parallel plate ionization chamber and Monte Carlo dose calculation in the build-up region. Then, percentage-depth-doses were measured for oblique beams at 0 degrees-80 degrees onto the flat solid water phantom with micro-MOSFET placed at depths of 2 cm, 1 cm, and 2 mm below the surface. Measurements were compared to Monte Carlo calculations under these settings. Finally, measurements were performed with micro-MOSFET embedded in the first 1 mm layer of bolus placed on a flat phantom and a curved phantom of semi-cylindrical shape. Results were compared to superficial dose calculated from Monte Carlo for a 2 mm thin layer that extends from the surface to a depth of 2 mm. Results were (1) Comparison of measurements with MC calculation in the build-up region showed that micro-MOSFET has a water-equivalence thickness (WET) of 0.87 mm for 6 MV beam and 0.99 mm for 10 MV beam from the flat side, and a WET of 0.72 mm for 6 MV beam and 0.76 mm for 10 MV beam from the epoxy side. (2) For normal beam incidences, percentage depth dose agree within 3%-5% among micro-MOSFET measurements, parallel-plate ionization chamber measurements, and MC calculations. (3) For oblique incidence on the flat phantom with micro-MOSFET placed at depths of 2 cm, 1 cm, and 2 mm, measurements were consistent with MC calculations within a typical uncertainty of 3%-5%. (4) For oblique incidence on the flat phantom and a curved-surface phantom, measurements with micro-MOSFET placed at 1.0 mm agrees with the MC calculation within 6%, including uncertainties of micro-MOSFET measurements of 2%-3% (1 standard deviation), MOSFET angular dependence of 3.0%-3.5%, and 1%-2% systematical error due to phantom setup geometry asymmetry. Micro-MOSFET can be used for skin dose measurements in 6 and 10 MV beams with an estimated accuracy of +/- 6%.


Assuntos
Modelos Biológicos , Radiometria/instrumentação , Radioterapia Conformacional/instrumentação , Fenômenos Fisiológicos da Pele/efeitos da radiação , Transistores Eletrônicos , Simulação por Computador , Relação Dose-Resposta à Radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Modelos Estatísticos , Método de Monte Carlo , Radiometria/métodos , Dosagem Radioterapêutica , Radioterapia Conformacional/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Acad Radiol ; 9(8): 906-12, 2002 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12186439

RESUMO

RATIONALE AND OBJECTIVES: The authors performed this study to document the deformations that occur between pretreatment magnetic resonance (MR) imaging and intraoperative MR imaging during brachytherapy. MATERIALS AND METHODS: MR images obtained at 1.5 and 0.5 T in 10 patients with prostate cancer were analyzed for changes in the shape and substructure of the prostate. Three-dimensional models of the prostate were obtained. The authors measured anteroposterior dimension; total gland, peripheral zone, and central gland volumes; transverse dimension; and superoinferior height. RESULTS: Gland deformations were seen at visual inspection of the three-dimensional models. The anteroposterior dimension of the total gland, central gland, and peripheral zone increased from 1.5- to 0.5-T imaging (median dimension, 4.9, 1.5, and 1.8 mm, respectively), and the increase was greatest in the peripheral zone (P < .05, all comparisons). There was a decrease in the transverse dimension from 1.5- to 0.5-T imaging (median, 4.5 mm; P < .005). The total gland volume and the superoinferior height did not show a statistically significant change. CONCLUSION: There were significant deformations in the shape of the prostate, especially in the peripheral zone, between the two imaging studies. The likely causes of the shape change are differences in rectal filling (endorectal coil used in 1.5-T studies vs obturator in 0.5-T studies) and/or changes in patient position (supine vs lithotomy). These findings suggest that pretreatment images alone may not be reliable for accurate therapy planning. It may be useful to integrate pre-and intraoperative data.


Assuntos
Imageamento por Ressonância Magnética/métodos , Próstata/patologia , Neoplasias da Próstata/patologia , Neoplasias da Próstata/radioterapia , Braquiterapia/métodos , Humanos , Imageamento Tridimensional , Cuidados Intraoperatórios , Masculino , Planejamento de Assistência ao Paciente , Cuidados Pré-Operatórios , Próstata/efeitos da radiação , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/cirurgia , Reprodutibilidade dos Testes , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA