1.
J Plast Reconstr Aesthet Surg ; 92: 264-275, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38582052

RESUMO

BACKGROUND: The increasing number of esthetic procedures emphasizes the need for effective evaluation methods of outcomes. Current practices include the individual practitioners' judgment in conjunction with standardized scales, often relying on the comparison of before and after photographs. This study investigates whether comparative evaluations influence the perception of beauty and aims to enhance the accuracy of esthetic assessments in clinical and research settings. OBJECTIVE: To compare the evaluation of attractiveness and gender characteristics of faces in group-based versus individual ratings. METHODS: A sample of 727 volunteers (average age of 29.5 years) assessed 40 facial photographs (20 male, 20 female) for attractiveness, masculinity, and femininity using a 5-point Likert scale. Each face was digitally edited to display varying ratios in four lip-related proportions: vertical lip position, lip width, upper lip esthetics, and lower lip esthetics. Participants rated these images both in an image series (group-based) and individually. RESULTS: Differences in the perception of the most attractive/masculine/feminine ratios for each lip proportion were found in both the group-based and individual ratings. Group ratings exhibited a significant central tendency bias, with a preference for more average outcomes compared with individual ratings, with an average difference of 0.50 versus 1.00. (p = 0.033) CONCLUSION: A central tendency bias was noted in evaluations of attractiveness, masculinity, and femininity in group-based image presentation, indicating a bias toward more "average" features. Conversely, individual assessments displayed a preference for more pronounced, "non-average" appearances, thereby possibly pointing toward a malleable "intrinsic esthetic blueprint" shaped by comparative context.


Assuntos
Beleza , Estética , Face , Humanos , Feminino , Masculino , Adulto , Face/anatomia & histologia , Fotografação , Masculinidade , Feminilidade , Adulto Jovem , Adolescente , Pessoa de Meia-Idade , Lábio/anatomia & histologia , Inquéritos e Questionários
3.
Eur Arch Otorhinolaryngol ; 280(9): 4271-4278, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37285018

RESUMO

PURPOSE: With the increasing adoption of artificial intelligence (AI) in various domains, including healthcare, there is growing acceptance and interest in consulting AI models to provide medical information and advice. This study aimed to evaluate the accuracy of ChatGPT's responses to practice quiz questions designed for otolaryngology board certification and decipher potential performance disparities across different otolaryngology subspecialties. METHODS: A dataset covering 15 otolaryngology subspecialties was collected from an online learning platform funded by the German Society of Oto-Rhino-Laryngology, Head and Neck Surgery, designed for board certification examination preparation. These questions were entered into ChatGPT, with its responses being analyzed for accuracy and variance in performance. RESULTS: The dataset included 2576 questions (479 multiple-choice and 2097 single-choice), of which 57% (n = 1475) were answered correctly by ChatGPT. An in-depth analysis of question style revealed that single-choice questions were associated with a significantly higher rate (p < 0.001) of correct responses (n = 1313; 63%) compared to multiple-choice questions (n = 162; 34%). Stratified by question categories, ChatGPT yielded the highest rate of correct responses (n = 151; 72%) in the field of allergology, whereas 7 out of 10 questions (n = 65; 71%) on legal otolaryngology aspects were answered incorrectly. CONCLUSION: The study reveals ChatGPT's potential as a supplementary tool for otolaryngology board certification preparation. However, its propensity for errors in certain otolaryngology areas calls for further refinement. Future research should address these limitations to improve ChatGPT's educational use. An approach, with expert collaboration, is recommended for the reliable and accurate integration of such AI models.


Assuntos
Inteligência Artificial , Otolaringologia , Humanos , Certificação , Escolaridade , Encaminhamento e Consulta
4.
Facial Plast Surg Clin North Am ; 30(2): 159-166, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35501053

RESUMO

Three-dimensional surface imaging (3DSI) has been shown to be a useful tool for plastic surgeons in the preoperative, intraoperative, and postoperative setting. The objective of this investigation was to compare the accuracy of facial surface distance measurements using both a handheld facial 3DSI device and a stationary whole-body 3DSI device. Users should be aware of deviations when obtaining 3DSI using the presented imaging devices but should not refrain from using them, as the absolute differences might be too small to play a role in both, clinical and research, settings.


Assuntos
Face , Imageamento Tridimensional , Face/diagnóstico por imagem , Face/cirurgia , Humanos , Imageamento Tridimensional/métodos
5.
J Cosmet Dermatol ; 21(3): 933-939, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35034418

RESUMO

OBJECTIVE: Quantifying the degree of dorsal hand atrophy is a challenging endeavor, but often necessary, in both the clinical and the research setting. The aim of this investigation was to create and consecutively validate a 5-point photonumeric scale for assessment of dorsal hand atrophy. MATERIAL AND METHODS: A medical team created a novel 5-point photonumeric scale. Twelve international raters were involved in the digital validation, while five raters performed a live validation. RESULTS: For the digital validation of the Croma Hand Atrophy Assessment Scale, a total of 72 subjects (58 females, 14 males) with a mean age of 43.0 ± 14.4 years [18-73 years] were assessed. For the live validation, 88 subjects (73 females, 15 males) with a mean age of 45.0 ± 14.1 years [20-73 years] were rated. The results revealed almost perfect intra-rater (ICC: 0.90 [95% CI: 0.88-0.92]) and inter-rater agreements (ICC: 0.85 [95% CI: 0.81-0.89] and 0.86 [95% CI:0.82-0.89]) in the digital validation and substantial intra-rater (ICC: 0.79 [95% CI: 0.75-0.82]) and inter-rater agreements (ICC: 0.75 [95% CI: 0.68-0.81] and ICC: 0.67 [95% CI: 0.54-0.77]) in the live validation. CONCLUSION: The created scale to assess dorsal hand atrophy has been shown to provide substantial-to-almost perfect agreement in the digital and live validation cycles and reached comparable intra-rater and inter-rater agreement to already published and validated scales. It is expected that the created scale will help physicians and researchers in the assessment of hand atrophy in the clinical and research setting in the future.


Assuntos
Reprodutibilidade dos Testes , Adulto , Atrofia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador
6.
J Cosmet Dermatol ; 21(2): 600-607, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34902199

RESUMO

OBJECTIVE: The objective of this investigation was to create and to examine the reproducibility and validity of 5-point photonumeric assessment scales that allow objective assessment of chin retrusion and jawline sagging using a digital and a live validation. MATERIAL AND METHODS: Two new 5-point photonumeric scales created to assess chin projection and jawline sagging were validated by 12 experts in a digital validation and by 5 experts in a live validation setting. Intra-rater agreement and inter-rater agreement were assessed. RESULTS: For the digital validation, an almost perfect intra-rater (Kappa: 0.89 [95% CI: 0.86-0.91]) and almost perfect inter-rater agreement in both sessions (Kappa: 0.80 [95% CI: 0.74-0.86] and 0.80 [95% CI: 0.74-0.86]) was achieved for the Croma Chin Projection Assessment Scale, while intra-rater agreement (Kappa: 0.88 [95% CI: 0.85-0.91]) was almost perfect for the Croma Jawline Sagging Assessment Scale and inter-rater agreement being substantial in the first session (Kappa: 0.76 [95% CI: 0.71-0.81]) and almost perfect in the second session (Kappa: 0.81 [95%CI: 0.76-0.85]). For the live validation, intra-rater agreement was almost perfect for the Croma Chin Projection Assessment Scale (Kappa: 0.82 [95%CI: 0.74-0.90]) and the Croma Jawline Sagging Assessment Scale (Kappa: 0.83 [95%CI: 0.77-0.89]), while inter-rater agreement was substantial in both sessions for both scales. CONCLUSION: The created chin and jawline photonumeric grading scales are valid and reliable tools for assessing chin projection and jawline sagging. The scales will be of value for standardized chin evaluation and quantifying outcomes in clinical research and daily practice.


Assuntos
Fotografação , Queixo , Humanos , Variações Dependentes do Observador , Reprodutibilidade dos Testes
7.
J Cosmet Dermatol ; 21(1): 158-166, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34865301

RESUMO

OBJECTIVE: The objective of this investigation was to create and validate 5-point photonumeric scales for the assessment of dynamic crow's feet, static crow's feet, and infraorbital hollows. MATERIAL AND METHODS: Three novel 5-point photonumeric scales were created by a medical team. A total of 12 raters from all over the world performed a digital validation, and a total of 5 raters a live validation of the created scale. RESULTS: The statistical analysis revealed almost perfect intra-rater and inter-rater reliability in the digital validation of the scales for the assessment of static and dynamic crow's feet as well as infraorbital hollows. In the live validation, both crow's feet scales showed almost perfect intra-rater reliability, while the Croma Infraorbital Hollow Assessment Scale showed substantial intra-rater reliability. Inter-rater reliability was substantial for all three scales in the live validation. All three scales, the Croma Dynamic Crow's Feet Assessment Scale, Croma Static Crow's Feet Assessment Scale, and Croma Infraorbital Hollow Assessment Scale, were validated digitally and in a live setting. CONCLUSION: The created scales to assess infraorbital hollowing, dynamic and static crow's feet have been shown to provide substantial to almost perfect agreement in the digital and live validation and can thus be considered as helpful tools in the clinical and research setting. While technical methods and appliances to assess the degrees of severity of age-dependent features are advancing, validated scales are of great importance due to their ease of use and, as shown by the validations, reliability, and reproducibility.


Assuntos
Envelhecimento da Pele , Face , Humanos , Reprodutibilidade dos Testes
8.
Aesthetic Plast Surg ; 45(6): 2751-2759, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33987696

RESUMO

BACKGROUND: 2D baseline and follow-up clinical images are potentially subject to inconsistency due to alteration of imaging parameters. However, no study to date has attempted to quantify the magnitude by which such images can be influenced. OBJECTIVE: The objective of the present study is to identify the magnitude by which images can be influenced by changing the imaging light angle. METHODS: This study is based on the evaluation of 2D frontal images of the face and included a total of 51 subjects of which n = 14 were males and n = 37 were females. Faces were photographed at 0°, 30°, and 60° light angle under identical and standardized conditions. Images were randomized and rated by 27 blinded raters for age, facial attractiveness, body mass index (BMI), temporal hollowing, lower cheek fullness, nasolabial sulcus severity, and jawline contour. RESULTS: Facial attractiveness decreased, facial unattractiveness increased and the evaluated BMI (based on facial assessment) increased statistically significantly at 60°. The assessment of regional facial scores, i.e., temporal hollowing, lower cheek fullness, and jawline contour, showed no statistically meaningful changes both at 30° and at 60° light angle. CONCLUSION: The results indicate that there might be an observed blind range in light angle (0°-30°) which does not influence facial assessment. Increasing the light angle past the threshold value to 60° might result in a statistically significant impact on facial perception which should be accounted for when documenting and/or presenting facial 2D images. LEVEL OF EVIDENCE V: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .


Assuntos
Face , Fotografação , Estética , Feminino , Humanos , Masculino , Percepção , Sensação
9.
Facial Plast Surg ; 37(5): 614-624, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33682916

RESUMO

The evaluation of neuromodulator treatment outcomes can be performed by noninvasive surface-derived facial electromyography (fEMG) which can detect cumulative muscle fiber activity deep to the skin. The objective of the present study is to identify the most reliable facial locations where the motor unit action potentials (MUAPs) of various facial muscles can be quantified during fEMG measurements. The study population consisted of five males and seven females (31.0 [12.9] years, body mass index of 22.15 [1.6] kg/m2). Facial muscle activity was assessed in several facial regions in each patient for their respective muscle activity utilizing noninvasive surface-derived fEMG. Variables of interest were the average root mean square of three performed muscle contractions (= signal) (µV), mean root mean square between those contraction with the face in a relaxed facial expression (= baseline noise) (µV), and the signal to noise ratio (SNR). A total of 1,709 processed fEMG signals revealed one specific reliable location in each investigated region based on each muscle's anatomy, on the highest value of the SNR, on the lowest value for the baseline noise, and on the practicability to position the sensor while performing a facial expression. The results of this exploratory study may help guiding future researchers and practitioners in designing study protocols and measuring individual facial MUAP when utilizing fEMG. The locations presented herein were selected based on the measured parameters (SNR, signal, baseline noise) and on the practicability and reproducibility of sensor placement.


Assuntos
Músculos Faciais , Contração Muscular , Eletromiografia , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Razão Sinal-Ruído
10.
Arthritis Care Res (Hoboken) ; 67(3): 374-81, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25302424

RESUMO

OBJECTIVE: To analyze the effect of contralateral knee pain on sensitivity of patient-reported outcomes and objectively measured functional performance tests in subjects with knee osteoarthritis (OA). METHODS: Subjects with discordant knee pain status (i.e., 1 knee being painful [≥4 on a numeric pain rating scale (NPRS)], with the contralateral knee being pain free [NPRS 0]) were selected from the Osteoarthritis Initiative and matched to subjects with bilaterally pain-free and painful knees by age, sex, body mass index, and radiographic knee OA. The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) physical function score, the global Physical Activity Scale for the Elderly (PASE), and objective functional performance tests were cross-sectionally compared in a matched case-control design. RESULTS: A total of 378 subjects with discordant knee pain status were matched to 359 controls with bilaterally pain-free knees and to 323 controls with bilaterally painful knees. WOMAC scores in pain-free knees of discordant knee pain cases significantly differed compared to scores of bilaterally pain-free knees (P = 0.003). Likewise, scores in painful knees of discordant knee pain cases significantly differed compared to scores of bilaterally painful knees (P < 0.001). PASE levels between these groups were not significantly different (P > 0.68). Functional performance tests differed in subjects with discordant knee pain compared to subjects with bilaterally pain-free knees and when compared to subjects with bilaterally painful knees, with the chair stand test showing the strongest effect size (standardized response mean 0.28 and 0.33, respectively). CONCLUSION: The WOMAC physical function score, although knee specific, is impacted by the contralateral knee pain status. The repeated chair stand test appears to be the most sensitive assessment in differentiation between groups with different status of knee pain.


Assuntos
Artralgia/fisiopatologia , Articulação do Joelho/fisiopatologia , Osteoartrite do Joelho/fisiopatologia , Idoso , Artralgia/diagnóstico , Fenômenos Biomecânicos , Estudos de Casos e Controles , Estudos Transversais , Avaliação da Deficiência , Teste de Esforço , Feminino , Humanos , Articulação do Joelho/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/diagnóstico , Medição da Dor , Radiografia , Índice de Gravidade de Doença , Fatores de Tempo , Caminhada
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA