Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Clin Med ; 11(5)2022 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-35268505

RESUMO

Fetal Heart Quantification (FetalHQ®) is a novel speckle tracking software that permits the study of global and regional ventricular shape and function from a 2D four-chamber-view loop. The 4D-Spatio Temporal Image Correlation (STIC) modality enables the offline analysis of optimized and perfectly aligned cardiac planes. We aimed to evaluate the feasibility and reproducibility of 4D-STIC speckle tracking echocardiography (STE) using FetalHQ® and to compare it to 2D STE. We conducted a prospective study including 31 low-risk singleton pregnancies between 20 and 40 weeks of gestation. Four-chamber view volumes and 2D clips were acquired with an apex pointing at 45° and with a frame rate higher than 60 Hz. Morphometric and functional echocardiography was performed by FetalHQ®. Intra- and interobserver reproducibility were evaluated by the intraclass correlation coefficient (ICC). Our results showed excellent reproducibility (ICC > 0.900) for morphometric evaluation (biventricular area, longitudinal and transverse diameters). Reproducibility was also good (ICC > 0.800) for functional evaluation (biventricular strain, Fractional Area Change, left ventricle volumes, ejection fraction and cardiac output). On the contrary, the study of the sphericity index and shortening fraction of the different ventricular segments showed lower reproducibility (ICC < 0.800). To conclude, 4D-STIC is feasible, reproducible and comparable to 2D echocardiography for the assessment of cardiac morphometry and function.

2.
Sci Rep ; 11(1): 14020, 2021 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-34234175

RESUMO

Cardiovascular research is in an ongoing quest for a superior imaging method to integrate gross-anatomical information with microanatomy, combined with quantifiable parameters of cardiac structure. In recent years, synchrotron radiation-based X-ray Phase Contrast Imaging (X-PCI) has been extensively used to characterize soft tissue in detail. The objective was to use X-PCI to comprehensively quantify ischemic remodeling of different myocardial structures, from cell to organ level, in a rat model of myocardial infarction. Myocardial infarction-induced remodeling was recreated in a well-established rodent model. Ex vivo rodent hearts were imaged by propagation based X-PCI using two configurations resulting in 5.8 µm and 0.65 µm effective pixel size images. The acquired datasets were used for a comprehensive assessment of macrostructural changes including the whole heart and vascular tree morphology, and quantification of left ventricular myocardial thickness, mass, volume, and organization. On the meso-scale, tissue characteristics were explored and compared with histopathological methods, while microstructural changes were quantified by segmentation of cardiomyocytes and calculation of cross-sectional areas. Propagation based X-PCI provides detailed visualization and quantification of morphological changes on whole organ, tissue, vascular as well as individual cellular level of the ex vivo heart, with a single, non-destructive 3D imaging modality.


Assuntos
Diagnóstico por Imagem/métodos , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/patologia , Síncrotrons , Remodelação Ventricular , Raios X , Animais , Vasos Coronários/diagnóstico por imagem , Modelos Animais de Doenças , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Microscopia de Contraste de Fase , Isquemia Miocárdica/terapia , Intervenção Coronária Percutânea , Ratos
3.
Eur Radiol ; 31(10): 7242-7250, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33787972

RESUMO

OBJECTIVES: Myocardial deformation integrated with cardiac dimensions provides a comprehensive assessment of cardiac function, which has proven useful to differentiate cardiac pathology from physiological adaptation to situations such as chronic intensive training. Feature tracking (FT) can measure myocardial deformation from cardiac magnetic resonance (CMR) cine sequences; however, its accuracy is not yet fully validated. Our aim was to compare the accuracy and reproducibility of FT with speckle tracking echocardiography (STE) in highly trained endurance athletes. METHODS: Ninety-three endurance athletes (> 12-h training/week during the last 5 years, 52% male, 35 ± 5.1 years old) and 72 age-matched controls underwent resting CMR and transthoracic echocardiography to assess biventricular exercise-induced remodeling and biventricular global longitudinal strain (GLS) by CMR-FT and STE. RESULTS: Strain values were significantly lower when assessed by CMR-FT compared to STE (p < 0.001), with good reproducibility for the left ventricle (bias = 3.94%, limit of agreement [LOA] = ± 4.27 %) but wider variability for right ventricle strain. Strain values by both techniques proportionally decreased with increasing ventricular volumes, potentially depicting the functional biventricular reserve that characterizes athletes' hearts. CONCLUSIONS: Biventricular longitudinal strain values were lower when assessed by FT as compared to STE. Both methods were statistically comparable when measuring LV strain but not RV strain. These differences might be justified by the lower in-plane spatial and temporal resolution of FT, which is particularly relevant for the complex anatomy of the RV. KEY POINTS: • Strain values were significantly lower when assessed by FT as compared to STE, which was expected due to the lower in-plane spatial and temporal resolution of FT versus STE. • Both methods were statistically comparable when measuring LV strain but not for RV strain analysis. • Characterizing the normal ranges and reproducibility of strain metrics by FT is an important step toward its clinical applicability, since it can be assessed offline and applied to routinely acquired cine CMR images.


Assuntos
Coração , Imagem Cinética por Ressonância Magnética , Adulto , Ecocardiografia , Feminino , Coração/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Humanos , Espectroscopia de Ressonância Magnética , Masculino , Reprodutibilidade dos Testes , Função Ventricular Esquerda
4.
PLoS One ; 13(12): e0208784, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30589837

RESUMO

BACKGROUND: We have used a previously reported rabbit model of fetal growth restriction (FGR), reproducing perinatal neurodevelopmental and cardiovascular impairments, to investigate the main relative changes in cerebral and cardiac metabolism of term FGR fetuses during nutrient infusion. METHODS: FGR was induced in 9 pregnant New Zealand rabbits at 25 days of gestation: one horn used as FGR, by partial ligation of uteroplacental vessels, and the contralateral as control (appropriate for gestation age, AGA). At 30 days of gestation, fasted mothers under anesthesia were infused i.v. with 1-13C-glucose (4 mothers), 2-13C-acetate (3 mothers), or not infused (2 mothers). Fetal brain and heart samples were quickly harvested and frozen down. Brain cortex and heart apex regions from 30 fetuses were studied ex vivo by HRMAS at 4°C, acquiring multinuclear 1D and 2D spectra. The data were processed, quantified by peak deconvolution or integration, and normalized to sample weight. RESULTS: Most of the total 13C-labeling reaching the fetal brains/hearts (80-90%) was incorporated to alanine and lactate (cytosol), and to the glutamine-glutamate pool (mitochondria). Acetate-derived lactate (Lac C2C3) had a slower turnover in FGR brains (~ -20%). In FGR hearts, mitochondrial turnover of acetate-derived glutamine (Gln C4) was slower (-23%) and there was a stronger accumulation of phospholipid breakdown products (glycerophosphoethanolamine and glycerophosphocholine, +50%), resembling the profile of non-infused control hearts. CONCLUSIONS: Our results indicate specific functional changes in cerebral and cardiac metabolism of FGR fetuses under nutrient infusion, suggesting glial impairment and restricted mitochondrial metabolism concomitant with slower cell membrane turnover in cardiomyocytes, respectively. These prenatal metabolic changes underlie neurodevelopmental and cardiovascular problems observed in this FGR model and in clinical patients, paving the way for future studies aimed at evaluating metabolic function postnatally and in response to stress and/or treatment.


Assuntos
Encéfalo/embriologia , Encéfalo/metabolismo , Retardo do Crescimento Fetal/metabolismo , Coração Fetal/metabolismo , Acetatos/metabolismo , Animais , Isótopos de Carbono , Modelos Animais de Doenças , Feminino , Glucose/metabolismo , Gravidez , Coelhos , Distribuição Aleatória , Análise Espectral
5.
Australas J Ultrasound Med ; 16(4): 158-167, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28191192

RESUMO

Introduction: Fetal heart evaluation with US is feasible and reproducible, although challenging due to the smallness of the heart, the high heart rate and limited access to the fetus. However, some cardiac parameters have already shown a strong correlation with outcomes and may soon be incorporated into clinical practice. Materials and Methods: Cardiac function assessment has proven utility in the differential diagnosis of cardiomyopathies or prediction of perinatal mortality in congenital heart disease. In addition, some cardiac parameters with high sensitivity such as MPI or annular peak velocities have shown promising results in monitoring and predicting outcome in intrauterine growth restriction or congenital diaphragmatic hernia. Conclusion: Cardiac function can be adequately evaluated in most fetuses when appropriate expertise, equipment and time are available. Fetal cardiac function assessment is a promising tool that may soon be incorporated into clinical practice to diagnose, monitor or predict outcome in some fetal conditions. Thus, more research is warranted to further define specific protocols for each fetal condition that may affect cardiac function.

6.
Fetal Diagn Ther ; 32(1-2): 30-8, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22626950

RESUMO

OBJECTIVE: Tissue Doppler echocardiography is being increasingly used in fetal medicine as a clinical and research tool. The objective of this study was to review the current status of tissue Doppler imaging (TDI) techniques applied to the fetus. METHODS: Fetal cardiac function was evaluated using spectral and color TDI modes in normal fetuses and in several clinical conditions. RESULTS: Annular peak velocities and their ratios as well as the myocardial performance index were evaluated using spectral TDI, and changes throughout gestation were described. Color TDI has several limitations in fetal life, particularly the use of low frame rates with current methods of acquisition and the lack of normal references for deformation parameters. CONCLUSIONS: Despite its limitations, TDI is a sensitive and promising method to evaluate fetal cardiac function.


Assuntos
Cardiopatias/diagnóstico por imagem , Cardiopatias/fisiopatologia , Coração/embriologia , Contração Miocárdica , Ultrassonografia Pré-Natal/métodos , Função Ventricular , Ecocardiografia Doppler , Ecocardiografia Doppler em Cores , Feminino , Coração/fisiologia , Coração/fisiopatologia , Cardiopatias/embriologia , Hérnia Ventral , Humanos , Gravidez , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA