Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Circ Arrhythm Electrophysiol ; 13(10): e008503, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32915063

RESUMO

BACKGROUND: In the WRAP-IT trial (Worldwide Randomized Antibiotic Envelope Infection Prevention), adjunctive use of an absorbable antibacterial envelope resulted in a 40% reduction of major cardiac implantable electronic device infection without increased risk of complication in 6983 patients undergoing cardiac implantable electronic device revision, replacement, upgrade, or initial cardiac resynchronization therapy defibrillator implant. There is limited information on the cost-effectiveness of this strategy. As a prespecified objective, we evaluated antibacterial envelope cost-effectiveness compared with standard-of-care infection prevention strategies in the US healthcare system. METHODS: A decision tree model was used to compare costs and outcomes of antibacterial envelope (TYRX) use adjunctive to standard-of-care infection prevention versus standard-of-care alone over a lifelong time horizon. The analysis was performed from an integrated payer-provider network perspective. Infection rates, antibacterial envelope effectiveness, infection treatment costs and patterns, infection-related mortality, and utility estimates were obtained from the WRAP-IT trial. Life expectancy and long-term costs associated with device replacement, follow-up, and healthcare utilization were sourced from the literature. Costs and quality-adjusted life years were discounted at 3%. An upper willingness-to-pay threshold of $150 000 per quality-adjusted life year was used to determine cost-effectiveness, in alignment with the American College of Cardiology/American Heart Association practice guidelines and as supported by the World Health Organization and contemporary literature. RESULTS: The base case incremental cost-effectiveness ratio of the antibacterial envelope compared with standard-of-care was $112 603/quality-adjusted life year. The incremental cost-effectiveness ratio remained lower than the willingness-to-pay threshold in 74% of iterations in the probabilistic sensitivity analysis and was most sensitive to the following model inputs: infection-related mortality, life expectancy, and infection cost. CONCLUSIONS: The absorbable antibacterial envelope was associated with a cost-effectiveness ratio below contemporary benchmarks in the WRAP-IT patient population, suggesting that the envelope provides value for the US healthcare system by reducing the incidence of cardiac implantable electronic device infection. Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02277990.


Assuntos
Antibacterianos/economia , Antibioticoprofilaxia/economia , Dispositivos de Terapia de Ressincronização Cardíaca/economia , Desfibriladores Implantáveis/economia , Custos de Medicamentos , Implantação de Prótese/economia , Infecções Relacionadas à Prótese/economia , Implantes Absorvíveis/economia , Antibacterianos/uso terapêutico , Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Tomada de Decisão Clínica , Redução de Custos , Análise Custo-Benefício , Árvores de Decisões , Desfibriladores Implantáveis/efeitos adversos , Humanos , Modelos Econômicos , Estudos Multicêntricos como Assunto , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/prevenção & controle , Qualidade de Vida , Anos de Vida Ajustados por Qualidade de Vida , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
2.
Heart Rhythm ; 11(3): 404-11, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24291414

RESUMO

BACKGROUND: An arteriovenous (AV) fistula is an infrequently reported complication of transvenous lead extraction (TLE), but may be under-recognized. OBJECTIVE: To determine the incidence, management, and outcomes of the AV fistula complicating TLE. METHODS: All TLE procedures from July 2001 to December 2012 were reviewed. RESULTS: Of 2471 patients who underwent TLE, the AV fistula occurred in 8 (0.3%; 6 pacemaker and 2 implantable cardioverter-defibrillator) procedures. Patients who developed an AV fistula had longer lead implant duration (11.8 [interquartile range 7.7] vs 5.2 [interquartile range 7.0] years) and were more likely to have required a powered sheath (8 of 8 [100%] vs 1392 of 2463 [56.5%]) compared to those who did not. Other procedural and demographic details did not discriminate. All patients had a continuous bruit along the anterior chest wall. Catheter angiography was more sensitive (100%) than computed tomography (75%) or ultrasound (25%) for confirming the diagnosis and identifying the vessels involved. One fistula closed spontaneously, while others were closed with covered stents (4) or surgical glue (1). One attempt at closure failed, and one was diagnosed postmortem. Mortality related to the AV fistula was 3 of 8 (37.5%). Patients who died all had structural heart disease. In the 5 patients with normal hearts, the AV fistula was well tolerated for up to 2 years. CONCLUSIONS: An AV fistula is an infrequent, though possibly under-recognized, complication of TLE. It requires a high index of suspicion for early diagnosis, may present late, and may be associated with significant morbidity and mortality in patients with structural heart disease.


Assuntos
Fístula Arteriovenosa/etiologia , Fístula Arteriovenosa/terapia , Remoção de Dispositivo , Eletrodos Implantados , Marca-Passo Artificial , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Fístula Arteriovenosa/mortalidade , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Resultado do Tratamento
3.
Expert Rev Med Devices ; 9(4): 367-76, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22905841

RESUMO

Traditional follow-up of cardiac implantable electronic devices involves the intermittent download of largely nonactionable data. Remote monitoring represents a paradigm shift from episodic office-based follow-up to continuous monitoring of device performance and patient and disease state. This lessens device clinical burden and may also lead to cost savings, although data on economic impact are only beginning to emerge. Remote monitoring technology has the potential to improve the outcomes through earlier detection of arrhythmias and compromised device integrity, and possibly predict heart failure hospitalizations through integration of heart failure diagnostics and hemodynamic monitors. Remote monitoring platforms are also huge databases of patients and devices, offering unprecedented opportunities to investigate real-world outcomes. Here, the current status of the field is described and future directions are predicted.


Assuntos
Prótese Vascular , Eletrodos Implantados , Eletrônica Médica/instrumentação , Monitorização Fisiológica/métodos , Tecnologia de Sensoriamento Remoto/métodos , Eletrodos Implantados/economia , Eletrônica Médica/economia , Humanos , Monitorização Fisiológica/economia , Satisfação do Paciente , Tecnologia de Sensoriamento Remoto/economia
4.
Heart Rhythm ; 9(10): 1619-26, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22772136

RESUMO

BACKGROUND: A significant proportion of implantable cardioverter-defibrillators (ICDs) have been subject to Food and Drug Administration (FDA) advisories. The impact of device advisories on mortality or patient care is poorly understood. Although estimated risks of ICD generators under advisory are low, dependency on ICD therapies to prevent sudden death justifies the assessment of long-term mortality. OBJECTIVE: To test the association of FDA advisory status with long-term mortality. METHODS: The study was a retrospective, single-center review of clinical outcomes, including device malfunctions, in patients from implantation to either explant or death. Patients with ICDs first implanted at Cleveland Clinic between August 1996 and May 2004 who became subject to FDA advisories on ICD generators were identified. Mortality was determined by using the Social Security Death Index. RESULTS: In 1644 consecutive patients receiving first ICD implants, 704 (43%) became subject to an FDA advisory, of which 172 (10.5%) were class I and 532 (32.3%) were class II. ICDs were explanted before advisory notifications in 14.0% of class I and 10.1% of class II advisories. Among ICDs under advisory, 28 (4.0%) advisory-related and 15 non-advisory- related malfunctions were documented. Over a median follow-up of 70 months, 814 patients died. Kaplan-Meier 5-year survival rate was 65.6% overall, and 64.2, 61.1, and 69.3% in patients with no, class I, and class II advisories, respectively (P = .17). CONCLUSIONS: ICD advisories impacted 43% of the patients. Advisory-related malfunctions affected 4% within the combined advisory group. Based on a conservative management strategy, ICDs under advisory were not associated with increased mortality over a background of significant disease-related mortality.


Assuntos
Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/efeitos adversos , Vigilância de Produtos Comercializados , Distribuição de Qui-Quadrado , Remoção de Dispositivo , Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Análise de Sobrevida , Estados Unidos , United States Food and Drug Administration
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA