Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Radiol Imaging Cancer ; 5(6): e230036, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37999629

RESUMO

Purpose To evaluate the feasibility of liver MR fingerprinting (MRF) for quantitative characterization and diagnosis of focal liver lesions. Materials and Methods This single-site, prospective study included 89 participants (mean age, 62 years ± 15 [SD]; 45 women, 44 men) with various focal liver lesions who underwent MRI between October 2021 and August 2022. The participants underwent routine clinical MRI, non-contrast-enhanced liver MRF, and reference quantitative MRI with a 1.5-T MRI scanner. The bias and repeatability of the MRF measurements were assessed using linear regression, Bland-Altman plots, and coefficients of variation. The diagnostic capability of MRF-derived T1, T2, T2*, proton density fat fraction (PDFF), and a combination of these metrics to distinguish benign from malignant lesions was analyzed according to the area under the receiver operating characteristic curve (AUC). Results Liver MRF measurements showed moderate to high agreement with reference measurements (intraclass correlation = 0.94, 0.77, 0.45, and 0.61 for T1, T2, T2*, and PDFF, respectively), with underestimation of T2 values (mean bias in lesion = -0.5%, -29%, 5.8%, and -8.2% for T1, T2, T2*, and PDFF, respectively). The median coefficients of variation for repeatability of T1, T2, and T2* values were 2.5% (IQR, 3.6%), 3.1% (IQR, 5.6%), and 6.6% (IQR, 13.9%), respectively. After considering multicollinearity, a combination of MRF measurements showed a high diagnostic performance in differentiating benign from malignant lesions (AUC = 0.92 [95% CI: 0.86, 0.98]). Conclusion Liver MRF enabled the quantitative characterization of various focal liver lesions in a single breath-hold acquisition. Keywords: MR Imaging, Abdomen/GI, Liver, Imaging Sequences, Technical Aspects, Tissue Characterization, Technology Assessment, Diagnosis, Liver Lesions, MR Fingerprinting, Quantitative Characterization Supplemental material is available for this article. © RSNA, 2023.


Assuntos
Neoplasias Hepáticas , Imageamento por Ressonância Magnética , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos , Abdome , Prótons , Neoplasias Hepáticas/diagnóstico por imagem
2.
Magn Reson Med ; 82(1): 312-325, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30896049

RESUMO

PURPOSE: To develop a motion-corrected 3D flow-insensitive imaging approach interleaved T2 prepared-inversion recovery (iT2 prep-IR) for simultaneous lumen and wall visualization of the great thoracic vessels and cardiac structures. METHODS: A 3D flow-insensitive approach for simultaneous cardiovascular lumen and wall visualization (iT2 prep) has been previously proposed. This approach requires subject-dependent weighted subtraction to completely null the arterial blood signal in the black-blood volume. Here, we propose an (T2 prep-IR) approach to improve wall visualization and remove need for weighted subtraction. The proposed sequence is based on the acquisition and direct subtraction of 2 interleaved 3D whole-heart data sets acquired with and without T2 prep-IR preparation. Image navigators are acquired before data acquisition to enable 2D translational and 3D non-rigid motion correction allowing 100% respiratory scan efficiency. The proposed approach was evaluated in 10 healthy subjects and compared with the conventional 2D double inversion recovery (DIR) sequence and the 3D iT2 prep sequence. Additionally, 5 patients with congenital heart disease were acquired to test the clinical feasibility of the proposed approach. RESULTS: The proposed iT2 prep-IR sequence showed improved blood nulling compared to both DIR and iT2 prep techniques in terms of SNR (SNRblood = 6.9, 12.2, and 18.2, respectively) and contrast-to-noise-ratio (CNRmyoc-blood = 28.4, 15.4, and 15.3, respectively). No statistical difference was observed between iT2 prep-IR, iT2 prep and DIR atrial and ventricular wall thickness quantification. CONCLUSION: The proposed interleaved T2 prep-IR sequence enables the simultaneous lumen and wall visualization of cardiac structures and shows promising results in terms of SNR, CNR, and wall thickness measurement.


Assuntos
Técnicas de Imagem Cardíaca/métodos , Coração/diagnóstico por imagem , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Adulto , Algoritmos , Feminino , Coração/fisiologia , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA