Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Int J Radiat Biol ; 99(2): 208-228, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35758985

RESUMO

BACKGROUND: There are few occupational studies of women exposed to ionizing radiation. During World War II, the Tennessee Eastman Corporation (TEC) operated an electromagnetic field separation facility of 1152 calutrons to obtain enriched uranium (235U) used for the Hiroshima atomic bomb. Thousands of women were involved in these operations. MATERIALS AND METHODS: A new study was conducted of 13,951 women and 12,699 men employed at TEC between 1943 and 1947 for at least 90 days. Comprehensive dose reconstruction techniques were used to estimate lung doses from the inhalation of uranium dust based on airborne measurements. Vital status through 2018/2019 was obtained from the National Death Index, Social Security Death Index, Tennessee death records and online public record databases. Analyses included standardized mortality ratios (SMRs) and Cox proportional hazards models. RESULTS: Most workers were hourly (77.7%), white (95.6%), born before 1920 (58.3%), worked in dusty environments (57.0%), and had died (94.9%). Vital status was confirmed for 97.4% of the workers. Women were younger than men when first employed: mean ages 25.0 years and 33.0 years, respectively. The estimated mean absorbed dose to the lung was 32.7 mGy (max 1048 mGy) for women and 18.9 mGy (max 501 mGy) for men. The mean dose to thoracic lymph nodes (TLNs) was 127 mGy. Statistically significant SMRs were observed for lung cancer (SMR 1.25; 95% CI 1.19, 1.31; n = 1654), nonmalignant respiratory diseases (NMRDs) (1.23; 95% CI 1.19, 1.28; n = 2585), and cerebrovascular disease (CeVD) (1.13; 95% CI 1.08, 1.18; n = 1945). For lung cancer, the excess relative rate (ERR) at 100 mGy (95% CI) was 0.01 (-0.10, 0.12; n = 652) among women, and -0.15 (-0.38, 0.07; n = 1002) among men based on a preferred model for men with lung doses <300 mGy. NMRD and non-Hodgkin lymphoma were not associated with estimated absorbed dose to the lung or TLN. CONCLUSIONS: There was little evidence that radiation increased the risk of lung cancer, suggesting that inhalation of uranium dust and the associated high-LET alpha particle exposure to lung tissue experienced over a few years is less effective in causing lung cancer than other types of exposures. There was no statistically significant difference in the lung cancer risk estimates between men and women. The elevation of certain causes of death such as CeVD is unexplained and will require additional scrutiny of workplace or lifestyle factors given that radiation is an unlikely contributor since only the lung and lymph nodes received appreciable dose.


Assuntos
Neoplasias Pulmonares , Doenças Profissionais , Exposição Ocupacional , Urânio , Masculino , Humanos , Feminino , Adulto , Urânio/efeitos adversos , Tennessee , Exposição Ocupacional/efeitos adversos , Doenças Profissionais/etiologia , Estudos de Coortes , Neoplasias Pulmonares/etiologia , Poeira
2.
Int J Radiat Biol ; 98(4): 722-749, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34047625

RESUMO

BACKGROUND: During World War II (WWII), the Manhattan Engineering District established a secret laboratory in the mountains of northern New Mexico. The mission was to design, construct and test the first atomic weapon, nicknamed 'The Gadget' that was detonated at the TRINITY site in Alamogordo, NM. After WWII, nuclear weapons research continued, and the laboratory became the Los Alamos National Laboratory (LANL). MATERIALS AND METHODS: The mortality experience of 26,328 workers first employed between 1943 and 1980 at LANL was determined through 2017. Included were 6157 contract workers employed by the ZIA Company. Organ dose estimates for each worker considered all sources of exposure, notably photons, neutrons, tritium, 238Pu and 239Pu. Vital status determination included searches within the National Death Index, Social Security Administration and New Mexico State Mortality Files. Standardized Mortality Ratios (SMR) and Cox regression models were used in the analyses. RESULTS: Most workers (55%) were hired before 1960, 38% had a college degree, 25% were female, 81% white, 13% Hispanic and 60% had died. Vital status was complete, with only 0.1% lost to follow-up. The mean dose to the lung for the 17,053 workers monitored for radiation was 28.6 weighted-mGy (maximum 16.8 weighted-Gy) assuming a Dose Weighting Factor of 20 for alpha particle dose to lung. The Excess Relative Risk (ERR) at 100 weighted-mGy was 0.01 (95%CI -0.02, 0.03; n = 839) for lung cancer. The ERR at 100 mGy was -0.43 (95%CI -1.11, 0.24; n = 160) for leukemia other than chronic lymphocytic leukemia (CLL), -0.06 (95%CI -0.16, 0.04; n = 3043) for ischemic heart disease (IHD), and 0.29 (95%CI 0.02, 0.55; n = 106) for esophageal cancer. Among the 6499 workers with measurable intakes of plutonium, an increase in bone cancer (SMR 2.44; 95%CI 0.98, 5.03; n = 7) was related to dose. The SMR for berylliosis was significantly high, based on 4 deaths. SMRs for Hispanic workers were significantly high for cancers of the stomach and liver, cirrhosis of the liver, nonmalignant kidney disease and diabetes, but the excesses were not related to radiation dose. CONCLUSIONS: There was little evidence that radiation increased the risk of lung cancer or leukemia. Esophageal cancer was associated with radiation, and plutonium intakes were linked to an increase of bone cancer. IHD was not associated with radiation dose. More precise evaluations will await the pooled analysis of workers with similar exposures such as at Rocky Flats, Savannah River and Hanford.


Assuntos
Neoplasias Esofágicas , Leucemia , Neoplasias Pulmonares , Neoplasias Induzidas por Radiação , Doenças Profissionais , Exposição Ocupacional , Plutônio , Feminino , Humanos , Exposição Ocupacional/efeitos adversos
3.
Med Phys ; 46(6): 2744-2751, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30955211

RESUMO

PURPOSE: To quantify the effects of operator head posture and different types of protective eyewear on the eye lens dose to operators in interventional radiology (IR). METHODS: A deformable computational human phantom, Rensselaer Polytechnic Institute (RPI) Adult Male, consisting of a high-resolution eye model, was used to simulate a radiologist who is performing an interventional radiology procedure. The radiologist phantom was deformed to a set of different head postures. Three different protective eyewear models were incorporated into the posture-deformed radiologist phantom. The eye lens dose of the radiologist was calculated using the Monte Carlo code, MCNP. Effects of the radiologist's head posture and different types of protective eyewear on eye lens doses were studied. The relationship between efficacy of protective eyewear and the radiologist's head posture was investigated. Effects of other parameters on efficacy of protective eyewear were also studied, including the angular position of the radiologist, the gap between the eyewear and the face of the radiologist, and the lead equivalent thickness. RESULTS: The dose to both lenses decreased by 80% as the head posture moved from looking downward to looking upward. Sports wrap glasses were found to reduce doses further than the other two studied models. The efficacy of eyewear was found to be related to radiologist's head posture as well. When the radiologist was looking up, the protective eyewear almost provided no protection to both lenses. Other factors such as the face-to-eyewear distance and the lead equivalent thickness were also found to have an impact on the efficacy of protective eyewear. The dose reduction factor (DRF), defined as the ratio of the dose to the lens without protection to that with protection, decreased from 4.25 to 1.07 as the face-to-eyewear distance increased. The DRF almost doubled when the lead equivalent thickness increased from 0.07 to 0.35 mm. However, further increase in lead equivalent thickness showed little improvement in dose reduction. CONCLUSION: The radiologist's head posture has a significant influence on the eye lens dose in IR. Sports wrap protective eyewear which conforms to the curve of the face is essential for the radiation protection of the eye lens. However, the radiologist's head posture and other exposure parameters should be considered when evaluating the protection of the radiologist's eyes.


Assuntos
Dispositivos de Proteção dos Olhos , Cabeça/fisiologia , Cristalino/efeitos da radiação , Método de Monte Carlo , Postura , Doses de Radiação , Radiologia Intervencionista , Artefatos , Humanos , Imagens de Fantasmas
4.
BMC Med Imaging ; 17(1): 28, 2017 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-28446130

RESUMO

BACKGROUND: Computed Tomography (CT) contributes up to 50% of the medical exposure to the United States population. Children are considered to be at higher risk of developing radiation-induced tumors due to the young age of exposure and increased tissue radiosensitivity. Organ dose estimation is essential for pediatric and adult patient cancer risk assessment. The objective of this study is to validate the VirtualDose software in comparison to currently available software and methods for pediatric and adult CT organ dose estimation. METHODS: Five age groups of pediatric patients and adult patients were simulated by three organ dose estimators. Head, chest, abdomen-pelvis, and chest-abdomen-pelvis CT scans were simulated, and doses to organs both inside and outside the scan range were compared. For adults, VirtualDose was compared against ImPACT and CT-Expo. For pediatric patients, VirtualDose was compared to CT-Expo and compared to size-based methods from literature. Pediatric to adult effective dose ratios were also calculated with VirtualDose, and were compared with the ranges of effective dose ratios provided in ImPACT. RESULTS: In-field organs see less than 60% difference in dose between dose estimators. For organs outside scan range or distributed organs, a five times' difference can occur. VirtualDose agrees with the size-based methods within 20% difference for the organs investigated. Between VirtualDose and ImPACT, the pediatric to adult ratios for effective dose are compared, and less than 21% difference is observed for chest scan while more than 40% difference is observed for head-neck scan and abdomen-pelvis scan. For pediatric patients, 2 cm scan range change can lead to a five times dose difference in partially scanned organs. CONCLUSIONS: VirtualDose is validated against CT-Expo and ImPACT with relatively small discrepancies in dose for organs inside scan range, while large discrepancies in dose are observed for organs outside scan range. Patient-specific organ dose estimation is possible using the size-based methods, and VirtualDose agrees with size-based method for the organs investigated. Careful range selection for CT protocols is necessary for organ dose optimization for pediatric and adult patients.


Assuntos
Envelhecimento/fisiologia , Modelos Biológicos , Exposição à Radiação/análise , Tomografia Computadorizada por Raios X/métodos , Vísceras/fisiologia , Contagem Corporal Total/métodos , Absorção de Radiação/fisiologia , Adolescente , Algoritmos , Criança , Pré-Escolar , Simulação por Computador , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Modelos Estatísticos , Método de Monte Carlo , Especificidade de Órgãos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Health Phys ; 112(2): 126-130, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-28027150

RESUMO

The use of radiation has a substantial beneficial impact, particularly in the areas of medicine, energy production, basic science research, and industrial applications. Radiation protection knowledge and experience are required for acquiring and implementing scientific knowledge to protect workers, members of the public, and the environment from potential harmful effects of ionizing radiation while facilitating the beneficial use and development of radiation-based technologies. However, demographic changes are negatively impacting U.S. radiation protection and response capabilities. The number of radiation professionals continues to decrease even as the demand for such professionals is growing. These concerns are most pronounced in the medical, energy, research, and security arenas. Though the United States has been the world leader in radiation protection and radiation sciences for many years, the country has no strategic plan to ensure the maintenance of expertise in radiobiology, radiation physics, and radiation protection. Solving this problem will require a significant increase in federal and state funding as well as formal partnerships and initiatives among academia, professional societies, government, and the private sector.


Assuntos
Emprego/tendências , Física Médica , Necessidades e Demandas de Serviços de Saúde/tendências , Mão de Obra em Saúde , Lesões por Radiação/prevenção & controle , Proteção Radiológica , Escolha da Profissão , Física Médica/tendências , Humanos , Estados Unidos
6.
Int J Radiat Oncol Biol Phys ; 88(3): 746-52, 2014 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-24411623

RESUMO

PURPOSE: A novel (32)P brachytherapy source has been in use at our institution intraoperatively for temporary radiation therapy of the spinal dura and other localized tumors. We describe the dosimetry and clinical implementation of the source. METHODS AND MATERIALS: Dosimetric evaluation for the source was done with a complete set of MCNP5 Monte Carlo calculations preceding clinical implementation. In addition, the depth dose curve and dose rate were measured by use of an electron field diode to verify the Monte Carlo calculations. Calibration procedures using the diode in a custom-designed phantom to provide an absolute dose calibration and to check dose uniformity across the source area for each source before treatment were established. RESULTS: Good agreement was established between the Monte Carlo calculations and diode measurements. Quality assurance measurements results are provided for about 100 sources used to date. Clinical source calibrations were usually within 10% of manufacturer specifications. Procedures for safe handling of the source are described. DISCUSSION: Clinical considerations for using the source are discussed.


Assuntos
Braquiterapia/métodos , Dura-Máter , Neoplasias Meníngeas/radioterapia , Método de Monte Carlo , Radioisótopos de Fósforo/uso terapêutico , Braquiterapia/instrumentação , Calibragem , Física Médica/métodos , Humanos , Neoplasias Meníngeas/patologia , Imagens de Fantasmas , Controle de Qualidade , Proteção Radiológica/instrumentação , Dosagem Radioterapêutica
7.
Radiat Prot Dosimetry ; 158(1): 51-8, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23918744

RESUMO

Four anthropomorphic phantoms (an adult male, an adult female, a 10-y-old child and a 5-y-old child) were exposed to bitewing radiographs at film and digital settings using both rectangular and round collimation. Optically stimulated dosemeters were used. For children, average organ doses were <40 µGy and the organs with the highest doses were the salivary glands, parotid, oral mucosa, skin and extrathoracic airway. For adults, average organ doses were <200 µGy. Highest adult doses were to the salivary glands, oral mucosa and skin. Effective doses ranged from 1.5 to 1.8 µSv for children and from 2.6 to 3.6 µSv for adults when optimised technique factors were employed, including digital receptors, rectangular collimation, size-appropriate exposure times and proper clinical judgment. Optimised doses were a fraction of the natural daily background exposure. Therefore, predictions of hypothetical cancer incidence or detriment in patient populations exposed to such low doses are highly speculative and should be discouraged.


Assuntos
Órgãos em Risco , Imagens de Fantasmas , Doses de Radiação , Radiografia Interproximal/normas , Adulto , Antropometria , Criança , Pré-Escolar , Simulação por Computador , Feminino , Humanos , Lactente , Masculino , Método de Monte Carlo
8.
BMC Med Imaging ; 11: 20, 2011 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-22004072

RESUMO

BACKGROUND: The purpose of this study is to explore how a patient's height and weight can be used to predict the effective dose to a reference phantom with similar height and weight from a chest abdomen pelvis computed tomography scan when machine-based parameters are unknown. Since machine-based scanning parameters can be misplaced or lost, a predictive model will enable the medical professional to quantify a patient's cumulative radiation dose. METHODS: One hundred mathematical phantoms of varying heights and weights were defined within an x-ray Monte Carlo based software code in order to calculate organ absorbed doses and effective doses from a chest abdomen pelvis scan. Regression analysis was used to develop an effective dose predictive model. The regression model was experimentally verified using anthropomorphic phantoms and validated against a real patient population. RESULTS: Estimates of the effective doses as calculated by the predictive model were within 10% of the estimates of the effective doses using experimentally measured absorbed doses within the anthropomorphic phantoms. Comparisons of the patient population effective doses show that the predictive model is within 33% of current methods of estimating effective dose using machine-based parameters. CONCLUSIONS: A patient's height and weight can be used to estimate the effective dose from a chest abdomen pelvis computed tomography scan. The presented predictive model can be used interchangeably with current effective dose estimating techniques that rely on computed tomography machine-based techniques.


Assuntos
Estatura , Peso Corporal , Militares , Doses de Radiação , Tomografia Computadorizada por Raios X , Feminino , Humanos , Masculino , Método de Monte Carlo , Imagens de Fantasmas , Valor Preditivo dos Testes , Radiografia Abdominal , Radiografia Torácica , Análise de Regressão , Estados Unidos
10.
BMC Med Imaging ; 7: 5, 2007 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-17367529

RESUMO

BACKGROUND: It is estimated that 60 million computed tomography (CT) scans were performed during 2006, with approximately 11% of those performed on children age 0-15 years. Various types of gonadal shielding have been evaluated for reducing exposure to the gonads. The purpose of this study was to quantify the radiation dose reduction to the gonads and its effect on image quality when a wrap-around male pediatric gonad shield was used during CT scanning. This information is obtained to assist the attending radiologist in the decision to utilize such male gonadal shields in pediatric imaging practice. METHODS: The dose reduction to the gonads was measured for both direct radiation and for indirect scattered radiation from the abdomen. A 6 cm3 ion chamber (Model 10X5-6, Radcal Corporation, Monrovia, CA) was placed on a Humanoid real bone pelvic phantom at a position of the male gonads. When exposure measurements with shielding were made, a 1 mm lead wrap-around gonadal shield was placed around the ion chamber sensitive volume. RESULTS: The use of the shields reduced scatter dose to the gonads by a factor of about 2 with no appreciable loss of image quality. The shields reduced the direct beam dose by a factor of about 35 at the expense of extremely poor CT image quality due to severe streak artifacts. CONCLUSION: Images in the direct exposure case are not useful due to these severe artifacts and the difficulties in positioning these shields on patients in the scatter exposure case may not be warranted by the small absolute reduction in scatter dose unless it is expected that the patient will be subjected to numerous future CT scans.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Proteção Radiológica/instrumentação , Radiografia Abdominal , Radiometria/métodos , Testículo , Tomografia Computadorizada Espiral , Adulto , Carga Corporal (Radioterapia) , Humanos , Masculino , Especificidade de Órgãos , Imagens de Fantasmas , Doses de Radiação , Proteção Radiológica/métodos , Eficiência Biológica Relativa , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
Brachytherapy ; 3(1): 1-6, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15110306

RESUMO

PURPOSE: To validate radiation safety instructions to patients and to evaluate the potential radiation doses to members of the public after (125)I or (103)Pd prostate implantation. METHODS AND MATERIALS: Radiation dose rate measurements were made in the immediate postoperative period on 636 consecutive patients with stage T1-T2 prostate cancer who underwent transperineal (125)I or (103)Pd implantation at Memorial Sloan-Kettering Cancer Center during the period from August 1995 through January 2003. RESULTS: The mean radiation dose rate at the anterior skin surface following a prostate implant was 37 microSv/hr for (125)I and 8 microSv/hr for (103)Pd. At 30 cm from the anterior skin surface, these dose rates were reduced to 6 microSv/hr for (125)I and 3 microSv/hr for (103)Pd. At 1 m from the anterior skin surface the dose rates from both types of implants were reduced to less than 1 microSv/hr. The effect of body weight on dose rates from (125)I sources was examined for a select sub-group of patients and the measured dose rate was found to decrease with increasing body weight. In another group of patients, dose rate measurements were made on both lateral skin surfaces and were less than 16.8 microSv/hr in all cases. Assuming a 33% occupancy factor and utilizing the mean measured dose rate for (125)I, the time required to reach an effective dose equivalent limit of 5 mSv for caregivers was estimated to be 19 days on contact with the skin surface. Using a similar calculation, the lifetime doses for (125)I at a distance of 30 cm from the anterior skin surface, as well as the lifetime doses for (103)Pd on contact with the skin surface and at 30 cm from the anterior skin surface can be shown to be less than 5 mSv. CONCLUSIONS: The large number of cases available for this study permits a validation of radiation safety recommendations and provides concrete information from which the permitted exposure times following implantation can be estimated. The data support the conclusion that patients treated with these implants do not represent a radiation risk to members of the public.


Assuntos
Braquiterapia/efeitos adversos , Neoplasias da Próstata/radioterapia , Humanos , Radioisótopos do Iodo , Masculino , Paládio , Educação de Pacientes como Assunto , Monitoramento de Radiação , Radioisótopos , Radiometria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA