Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Aliment Pharmacol Ther ; 47(12): 1682-1689, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29665081

RESUMO

BACKGROUND: In liver transplant recipients with hepatitis C virus recurrence, there is concern about renal safety of sofosbuvir-based regimens. Changes in serum creatinine or in the estimated glomerular filtration rate (eGFR) under treatment are used to look for possible renal toxicity. However, serum creatinine and eGFR are highly variable. AIM: To analyse renal function trajectory with numerous assays of serum creatinine over a long period of time. METHODS: In a multicentre cohort of 139 patients, the eGFR was obtained from serum creatinine using the Chronic Kidney Disease-Epidemiology Collaboration (CKD-EPI) equation. Slopes of eGFR were defined as a change in eGFR during a period divided by time. Pre-treatment, on-treatment and post-treatment periods were 9 months, 3-9 months and 4.5 months. Interactions between eGFR slopes and the pre-treatment eGFR, use of ribavirin or mycophenolate mofetil, and stage of fibrosis were addressed. On-treatment eGFR slopes were separated in tertiles. Pre- and post-treatment eGFR slopes were compared globally and according to tertiles. RESULTS: The post-treatment eGFR slope was significantly better than pre-treatment eGFR slope (+0.18 (IQR -0.76 to +1.32) vs -0.11 (IQR -1.01 to +0.73) mL/min/1.73 m2 /month, P = 0.03) independently of the pre-treatment eGFR (P = 0.99), ribavirin administration (P = 0.26), mycophenolate mofetil administration (P = 0.51) and stage of fibrosis (F3 and F4 vs lower stages, P = 0.18; F4 vs lower stages, P = 0.08; F4 Child-Pugh B and C vs lower stages, P = 0.38). Tertiles of on-treatment eGFR slopes were -1.71 (IQR -2.54 to -1.48), -0.78 (IQR -1.03 to -0.36) and +0.75 (IQR +0.28 to +1.47) mL/min/1.73 m2 /month. Pre- and post-treatment eGFR slopes were not significantly different according to tertiles (respectively, P = 0.34, 0.08, 0.73). CONCLUSION: The eGFR varies during treatment and gives a confusing picture of the renal safety of sofosbuvir-based regimens. In contrast, longitudinal assessment of the eGFR shows a rising trajectory over longer time, meaning that these therapies are safe for the kidneys in our cohort of liver transplant recipients.


Assuntos
Hepatite C/tratamento farmacológico , Rim/patologia , Transplante de Fígado/métodos , Sofosbuvir/administração & dosagem , Idoso , Estudos de Coortes , Creatinina/sangue , Feminino , Taxa de Filtração Glomerular , Hepacivirus/isolamento & purificação , Humanos , Estudos Longitudinais , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Insuficiência Renal Crônica/epidemiologia , Ribavirina/administração & dosagem , Sofosbuvir/efeitos adversos
2.
J Viral Hepat ; 19(4): 244-53, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22404722

RESUMO

A novel controlled attenuation parameter (CAP) has been developed for Fibroscan(®) to assess liver steatosis, simultaneously with liver stiffness measurement (LSM). We assessed CAP diagnostic accuracy in a large cohort of patients with chronic hepatitis C (CHC) virus. A total of 615 patients with CHC, who underwent both Fibroscan(®) and liver biopsy, were analysed. Fibrosis was graded using METAVIR score. Steatosis was categorized by visual assessment as S(0) : steatosis in <10% of hepatocytes, S(1) : 11-33%, S(2) : 34-66% and S(3) : 67-100%. Performances of CAP and liver stiffness were determined using receiver operating characteristic (ROC) curve analysis and cross-validated using the bootstrap method. The Obuchowski measure was used to assess overall accuracy of CAP and to differentiate between steatosis grades. In multivariate analysis, CAP was related to steatosis (P < 10(-15) ) independently of fibrosis stage (which was related to LSM). The areas under ROC curves using CAP to detect steatosis were 0.80 (95% CI, 0.75-0.84) for S ≥ S(1) , 0.86 (0.81-0.92) for S ≥ S(2) and 0.88 (0.73-1) S = S(3) . CAP exhibited a good ability to differentiate steatosis grades (Obuchowski measure = 0.92). Performance of LSM for fibrosis assessment confirmed results from previous studies. CAP is a novel tool to assess the degree of steatosis and both fibrosis and steatosis can be evaluated noninvasively during the same procedure using Fibroscan(®) , in patients with CHC.


Assuntos
Técnicas de Laboratório Clínico/métodos , Fígado Gorduroso/diagnóstico , Fígado Gorduroso/patologia , Hepatite C Crônica/complicações , Hepatite C Crônica/patologia , Adulto , Biópsia , Técnicas de Imagem por Elasticidade , Feminino , Humanos , Fígado/patologia , Masculino , Pessoa de Meia-Idade , Curva ROC , Índice de Gravidade de Doença
3.
Aliment Pharmacol Ther ; 33(4): 455-65, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21235598

RESUMO

BACKGROUND: Non invasive methods for fibrosis evaluation remain to be validated longitudinally in hepatitis B. AIM: To evaluate longitudinally transient elastography (TE) and biomarkers for liver fibrosis assessment and follow-up of hepatitis B virus (HBV) inactive carriers. METHODS: Three hundred and twenty-nine consecutive HBeAg-negative HBV patients (201 inactive carriers) who underwent TE, Fibrotest and aspartate to platelet ratio index (APRI) the same day were studied. RESULTS: TE (median 4.8 vs. 6.8 kPa, P < 0.0001), Fibrotest (0.16 vs. 0.35, P < 0.0001) and APRI values (0.28 vs. 0.43, P < 0.0001) were significantly lower in inactive carriers than in the remaining patients whereas they did not differ among inactive carriers according to HBV DNA levels. In 82 inactive carriers with repeated examinations, although differences were observed among individual patients, TE values did not differ significantly over time (median intra-patient changes at end of follow-up relative to baseline: -0.2 kPa, P = 0.12). Conversely, significant fluctuations were observed for Fibrotest (+0.03, P = 0.012) and APRI (-0.01, P < 0.05). Eleven inactive carriers (5.5%) had initial elevated TE values (>7.2 kPa) confirmed during follow-up in two with significant fibrosis (F2 and F3) on liver biopsy. CONCLUSION: Non-invasive tools, particularly TE, could be useful, in addition to HBV DNA and transaminase levels, for follow-up of HBV inactive carriers as well as better selection of patients who require a liver biopsy.


Assuntos
Biomarcadores/sangue , Técnicas de Imagem por Elasticidade/métodos , Hepatite B/complicações , Cirrose Hepática/diagnóstico , Adulto , Alanina Transaminase/sangue , Aspartato Aminotransferases/sangue , Portador Sadio , Estudos Transversais , Feminino , Hepatite B/diagnóstico por imagem , Vírus da Hepatite B , Humanos , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/fisiopatologia , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Índice de Gravidade de Doença , Estatística como Assunto
4.
Gastroenterol Clin Biol ; 34(6-7): 388-96, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20580175

RESUMO

BACKGROUND: ActiTest (AT) is a biomarker of liver necro-inflammatory histological activity validated in patients with chronic hepatitis C (HCV). AIM: The aim was to assess the accuracy of AT in comparison with alanine aminotransferase (ALT) the standard of care. METHODS: Methods used an integrated database of individual data and the new recommended Obuchowski measures. An updated "classical" meta-analysis of AT validation studies was also performed. The main end points were the area under the ROC curves (AUROCs) for the diagnosis of each histological activity grade defined using METAVIR scoring system. To avoid repeated tests and the spectrum effect of activity grades prevalence, the comparison of AT and ALT accuracies used the Obuchowski method. RESULTS: For the individual analysis, a total of 1250 patients were included and for the meta-analysis six studies (2017 patients) were included. The overall accuracy of AT for the diagnosis of any activity grade (Obuchowski measure=0.850) was significantly higher than the accuracy of ALT (Obuchowski measure=0.837; P=0.009). The updated standard meta-analysis confirmed the accuracy of AT (p<0.0001) both in independent AUROC=0.79 (95% CI, 0.73-0.85) and in non independent studies AUROC=0.74 (95% CI, 0.67-0.81). CONCLUSIONS: The accuracy of AT for grading the necro-inflammatory activity of patients with HCV was significantly higher than ALT serum activity alone, the standard biomarker.


Assuntos
Alanina Transaminase/sangue , Hepatite C Crônica/sangue , Hepatite C Crônica/patologia , Curva ROC , Adulto , Biomarcadores/sangue , Biópsia , Análise Química do Sangue , Feminino , Humanos , Fígado/patologia , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA