1.
Int J Legal Med ; 133(1): 163-167, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29600323

RESUMO

SYNBONE® spheres were impacted with 7.62 × 39 mm mild steel core ammunition at a mean impact velocity of 654 m/s, SD 7 m/s, to simulate engagement distances of around 50-100 m. The wounds and fracture patterns were assessed by two forensic pathologists familiar with military cranial injury. The overall fracture pattern was assessed as being too comminuted when compared with actual injury. This suggests the SYNBONE® spheres have less utility for simulating military injury than other purposes described in the literature.


Assuntos
Traumatismos Cranianos Penetrantes , Modelos Biológicos , Crânio/lesões , Ferimentos por Arma de Fogo , Balística Forense/instrumentação , Balística Forense/métodos , Gelatina , Dispositivos de Proteção da Cabeça , Humanos , Militares , Poliuretanos , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA