Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Rheumatol Adv Pract ; 7(3): rkad072, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37675202

RESUMO

Objectives: The aim was to explore the inter-reliability of a newly developed US scanning protocol (multimodal US) for the assessment of different aspects of sarcopenia-related muscle involvement, including muscle mass, muscle quality and muscle stiffness [using point shear-wave elastography (SWE)], in patients with rheumatic and musculoskeletal diseases (RMDs). Methods: Quadriceps muscle mass (i.e. muscle thickness), muscle quality (i.e. muscle echogenicity evaluated with both a visual semi-quantitative scale and a dedicated software package for image analysis, ImageJ) and point SWE measurements were obtained by two rheumatologists (blinded to each other's evaluation) in consecutive RMD patients without previous/current myositis or neuromuscular disorders.Inter-reliability was assessed using the intraclass correlation coefficient (ICC) for continuous variables and Cohen's kappa (κ) for categorical variables. Results: A total of 45 RMD patients were enrolled [mean age 54.5 (16.0) years, male-to-female ratio 1:1.5, mean BMI 24.6 (4.6) kg/m2], 10 with PsA, 7 RA, 5 AS, 5 PMR, 4 SLE, 4 gout, 4 OA, 3 FM and 3 SSc. The grade of inter-rater reliability was excellent for muscle mass [ICC = 0.969 (0.953 < ICC < 0.979)]. Regarding muscle echogenicity, the agreement was substantial/almost perfect using the visual semi-quantitative scale (weighted linear = 0.793, weighted squared = 0.878) and excellent using ImageJ analysis [ICC = 0.916 (0.876 < ICC < 0.944)]. Finally, a good agreement was obtained for point SWE measurements [ICC = 0.76 (0.712 < ICC < 0.8)]. Conclusion: Multimodal US is a novel and reliable tool for the evaluation of different aspects of muscle involvement (muscle mass, muscle quality and muscle stiffness) in RMD patients.

2.
RMD Open ; 9(1)2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36927850

RESUMO

OBJECTIVE: To test whether the double contour (DC) sign has a different dynamic behaviour in gout and calcium pyrophosphate deposition (CPPD) and whether the dynamic assessment of the DC sign increases its accuracy in gout diagnosis. METHODS: This cross-sectional analysis included patients with gout meeting the 2015 ACR/EULAR classification criteria and patients with crystal-proven diagnosis of CPPD. Hyaline cartilages were explored by ultrasound (US) to detect the DC sign (ie, abnormal hyperechoic band over the superficial margin of hyaline cartilages) and its dynamic behaviour during joint movement was evaluated ((ie, movement of the DC sign together with subchondral bone (DC sign), or in the opposite direction (pseudo DC sign)). RESULTS: Eighty-one patients with gout and 84 patients with CPPD underwent US assessment. Among them, 47 patients with gout and 9 patients with CPPD had evidence of the DC sign. During dynamic assessment, in all 47/47 patients with gout there was a DC sign. Conversely, in 7/9 (77.8%) patients with CPPD, there was a pseudo DC sign (p<0.01).The presence of DC sign during static assessment had a sensitivity, specificity and accuracy of 58.0% (95% CI 46.5% to 68.9%), 89.3% (95% CI 80.6% to 95.0%) and 73.9% (95% CI 66.5% to 80.5%) for gout, respectively. The dynamic evaluation improved the DC sign's diagnostic performance (p=0.01) as the specificity (97.6% (95% CI 91.7% to 99.7%)) and the accuracy (78.2% (95% CI 71.1% to 84.2%)) increased without loss in sensitivity. CONCLUSION: The dynamic US assessment of the DC sign may help to differentiate the DC sign due to MSU crystals from the pseudo DC sign seen in CPPD, as they move in opposite directions.


Assuntos
Calcinose , Condrocalcinose , Gota , Humanos , Condrocalcinose/diagnóstico por imagem , Estudos Transversais , Gota/diagnóstico por imagem , Pirofosfato de Cálcio , Ultrassonografia
4.
Rheumatology (Oxford) ; 61(12): 4863-4874, 2022 11 28.
Artigo em Inglês | MEDLINE | ID: mdl-35293988

RESUMO

OBJECTIVES: To investigate the reliability of the OMERACT US Task Force definition of US enthesitis in SpA. METHODS: In this web exercise, based on the evaluation of 101 images and 39 clips of the main entheses of the lower limbs, the elementary components included in the OMERACT definition of US enthesitis in SpA (hypoechoic areas, entheseal thickening, power Doppler signal at the enthesis, enthesophytes/calcifications, bone erosions) were assessed by 47 rheumatologists from 37 rheumatology centres in 15 countries. Inter- and intra-observer reliability of the US components of enthesitis was calculated using Light's kappa, Cohen's kappa, Prevalence And Bias Adjusted Kappa (PABAK) and their 95% CIs. RESULTS: Bone erosions and power Doppler signal at the enthesis showed the highest overall inter-reliability [Light's kappa: 0.77 (0.76-0.78), 0.72 (0.71-0.73), respectively; PABAK: 0.86 (0.86-0.87), 0.73 (0.73-0.74), respectively], followed by enthesophytes/calcifications [Light's kappa: 0.65 (0.64-0.65), PABAK: 0.67 (0.67-0.68)]. This was moderate for entheseal thickening [Light's kappa: 0.41 (0.41-0.42), PABAK: 0.41 (0.40-0.42)], and fair for hypoechoic areas [Light's kappa: 0.37 (0.36-0.38); PABAK: 0.37 (0.37-0.38)]. A similar trend was observed in the intra-reliability exercise, although this was characterized by an overall higher degree of reliability for all US elementary components compared with the inter-observer evaluation. CONCLUSIONS: The results of this multicentre, international, web-based study show a good reliability of the OMERACT US definition of bone erosions, power Doppler signal at the enthesis and enthesophytes/calcifications. The low reliability of entheseal thickening and hypoechoic areas raises questions about the opportunity to revise the definition of these two major components for the US diagnosis of enthesitis.


Assuntos
Entesopatia , Humanos , Reprodutibilidade dos Testes , Entesopatia/diagnóstico por imagem , Ultrassonografia/métodos , Ultrassonografia Doppler/métodos , Internet
5.
Rheumatology (Oxford) ; 61(12): 4775-4785, 2022 11 28.
Artigo em Inglês | MEDLINE | ID: mdl-35333315

RESUMO

OBJECTIVES: The objectives of this study were (1) to explore US findings for muscle mass, muscle quality and muscle stiffness in SLE patients and healthy subjects; (2) to investigate the relationship between the US muscle findings and physical performance in SLE patients and healthy subjects. METHODS: Quadriceps muscle thickness was used for assessment of muscle mass, muscle echogenicity (using a visual semi-quantitative scale and grayscale analysis with histograms) for assessment of muscle quality, and point shear-wave elastography (SWE) for assessment of muscle stiffness in 30 SLE patients (without previous/current myositis or neuromuscular disorders) and 15 age-, sex- and BMI-matched healthy subjects. Hand grip strength tests and short physical performance battery (SPPB) tests were carried out in the same populations. RESULTS: No difference was observed between SLE patients and healthy subjects for quadriceps muscle thickness (35.2 mm ±s.d. 6.8 vs 34.8 mm ± s.d. 6.0, respectively, P = 0.79). Conversely, muscle echogenicity was significantly increased in SLE patients (visual semi-quantitative scale: 1.7 ± s.d. 1.0 vs 0.3 ± s.d. 0.5, respectively, P < 0.01; grayscale analysis with histograms: 87.4 mean pixels ± s.d. 18.8 vs 70.1 mean pixels ± s.d. 14.0, respectively, P < 0.01). Similarly, SWE was significantly lower in SLE patients compared with healthy subjects {1.5 m/s [interquartile range (IQR) 0.3] vs 1.6 m/s (IQR 0.2), respectively, P = 0.01}. Muscle echogenicity was inversely correlated with grip strength (visual semi-quantitative scale, Rho: -0.47, P = 0.01; grayscale analysis with histograms, Rho: -0.41, p < 0.01) and SPPB (visual semi-quantitative scale, Rho: -0.50, P < 0.01; grayscale analysis with histograms Rho: -0,46, P < 0.01). CONCLUSIONS: US assessment of muscle echogenicity and stiffness is useful for the early detection of muscle involvement in SLE patients.


Assuntos
Força da Mão , Lúpus Eritematoso Sistêmico , Humanos , Ultrassonografia , Lúpus Eritematoso Sistêmico/diagnóstico por imagem , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/fisiologia , Desempenho Físico Funcional
6.
Rheumatology (Oxford) ; 61(3): 1018-1025, 2022 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-34097001

RESUMO

OBJECTIVE: To test the validity of the OMERACT semi-quantitative score by comparing with a quantitative method in the US assessment of hyaline cartilage at the metacarpal head (MH) in patients with RA and healthy controls (HCs). METHODS: The hyaline cartilage from the second to fifth MHs of both hands was scanned. Hyaline cartilage was scored semi-quantitatively and quantitatively by measuring cartilage thickness and comparing with reference values. In RA patients, radiographic joint space narrowing (JSN) was scored on the same joints using the Simple Erosion Narrowing Score (SENS). RESULTS: A total of 408 MHs in 51 RA patients and 320 MHs in 40 HSs were evaluated. The OMERACT semi-quantitative score was quicker to perform than the quantitative method [6.0 min (s.d. 0.5) vs 8.0 (1.5); P < 0.01]. A significant correlation between the US scores (R = 0.68) and between the US scores and the JSN-SENS (R = 0.61 and R = 0.63 for the semi-quantitative and quantitative method, respectively) was found. The frequency of cartilage abnormalities was similar between the two US methods in RA patients (58.8% and 51.0% of RA patients for the semi-quantitative and quantitative method, respectively; P = 0.46), while the former revealed more abnormalities in HCs (27.5% and 7.5% of HCs; P = 0.02). CONCLUSION: The higher feasibility of the OMERACT semi-quantitative score suggests its use as a first-choice method in the evaluation of cartilage damage. However, despite its limits, the quantitative assessment of HCs, providing patient-tailored information with age- and sex-corrected cut-off values, may represent a valid supplement for optimizing the evaluation of cartilage damage in selected cases.


Assuntos
Artrite Reumatoide/diagnóstico por imagem , Doenças das Cartilagens/diagnóstico por imagem , Articulação Metacarpofalângica/diagnóstico por imagem , Ultrassonografia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
7.
Ultraschall Med ; 43(5): e65-e72, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33126276

RESUMO

PURPOSE: i) To assess the inter- and intra-observer reliability of ultrasound (US) in the evaluation of the hyaline cartilage (HC) of the metacarpal head (MH) in patients with rheumatoid arthritis (RA) and in healthy subjects (HS) both qualitatively and quantitatively. ii) To calculate the smallest detectable difference (SDD) of the MH cartilage thickness measurement. iii) To correlate the qualitative scoring system and the quantitative assessment. MATERIALS AND METHODS: US examination was performed on 280 MHs of 20 patients with RA and 15 HS using a very high frequency probe (up to 22 MHz). HC status was evaluated both qualitatively (using a five-grade scoring system) and quantitatively (using the average value of the longitudinal and transverse measures). The HC of MHs from II to V metacarpophalangeal joint of both hands were scanned independently on the same day by two rheumatologists to assess inter-observer reliability. All subjects were re-examined using the same scanning protocol and the same US setting by one sonographer after a week to assess intra-observer reliability. RESULTS: The inter-observer agreement and intra-observer agreement were moderate to substantial (k = 0.66 and k = 0.73) for the qualitative scoring system and high (ICC = 0.93 and ICC = 0.94) for the quantitative assessment. The SDD of the MH cartilage thickness measurement was 0.09 mm. A significant correlation between the two scoring systems was found (r = -0.35; p < 0.001). CONCLUSION: The present study describes the main methodological issues of HC assessment. Using a standardized protocol, both the qualitative and the quantitative scoring systems can be reliable.


Assuntos
Artrite Reumatoide , Ossos Metacarpais , Artrite Reumatoide/diagnóstico por imagem , Humanos , Cartilagem Hialina/diagnóstico por imagem , Ossos Metacarpais/diagnóstico por imagem , Variações Dependentes do Observador , Reprodutibilidade dos Testes
8.
Front Med (Lausanne) ; 9: 1090468, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36733934

RESUMO

Objectives: To investigate the inter/intra-reliability of ultrasound (US) muscle echogenicity in patients with rheumatic diseases. Methods: Forty-two rheumatologists and 2 radiologists from 13 countries were asked to assess US muscle echogenicity of quadriceps muscle in 80 static images and 20 clips from 64 patients with different rheumatic diseases and 8 healthy subjects. Two visual scales were evaluated, a visual semi-quantitative scale (0-3) and a continuous quantitative measurement ("VAS echogenicity," 0-100). The same assessment was repeated to calculate intra-observer reliability. US muscle echogenicity was also calculated by an independent research assistant using a software for the analysis of scientific images (ImageJ). Inter and intra reliabilities were assessed by means of prevalence-adjusted bias-adjusted Kappa (PABAK), intraclass correlation coefficient (ICC) and correlations through Kendall's Tau and Pearson's Rho coefficients. Results: The semi-quantitative scale showed a moderate inter-reliability [PABAK = 0.58 (0.57-0.59)] and a substantial intra-reliability [PABAK = 0.71 (0.68-0.73)]. The lowest inter and intra-reliability results were obtained for the intermediate grades (i.e., grade 1 and 2) of the semi-quantitative scale. "VAS echogenicity" showed a high reliability both in the inter-observer [ICC = 0.80 (0.75-0.85)] and intra-observer [ICC = 0.88 (0.88-0.89)] evaluations. A substantial association was found between the participants assessment of the semi-quantitative scale and "VAS echogenicity" [ICC = 0.52 (0.50-0.54)]. The correlation between these two visual scales and ImageJ analysis was high (tau = 0.76 and rho = 0.89, respectively). Conclusion: The results of this large, multicenter study highlighted the overall good inter and intra-reliability of the US assessment of muscle echogenicity in patients with different rheumatic diseases.

9.
Clin Rheumatol ; 40(3): 1085-1092, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32696282

RESUMO

OBJECTIVES: To comparatively assess the sonographic spectrum of carpal tunnel syndrome (CTS) in patients with rheumatoid arthritis (RA) and in patients with idiopathic CTS. METHODS: Fifty-seven RA patients and 25 idiopathic CTS patients were consecutively enrolled. The diagnosis of CTS in RA patients was made according to clinical history and examination. The following sonographic findings were assessed at carpal tunnel level: median nerve cross-sectional area (CSA) at the carpal tunnel proximal inlet, finger flexor tendons tenosynovitis, radio-carpal synovitis and intraneural power Doppler (PD) signal. RESULTS: CTS was diagnosed in 15/57 RA patients (26.3%). Twenty-three RA wrists with CTS, 84 RA wrists without CTS and 34 idiopathic CTS wrists were evaluated. The average CSA of the median nerve was higher in idiopathic CTS than in RA wrists with CTS (17.7 mm2 vs 10.6 mm2, p < 0.01). A higher rate of inflammation of synovial structures (flexor tendons sheath and/or radio-carpal joint) was found in RA wrists with CTS compared with those without CTS (p = 0.04) and idiopathic CTS (p = 0.02). Intraneural PD signal was more common in CTS (in both RA and idiopathic CTS) wrists compared with wrists without CTS (p < 0.01). CONCLUSION: The sonographic spectrum of CTS in RA patients is characterized by an inflammatory pattern, defined by the presence of finger flexor tendons tenosynovitis and/or radio-carpal joint synovitis. Conversely, a marked median nerve swelling is the dominant feature in idiopathic CTS. Intraneural PD signal is a frequent finding in both conditions. Key Points • Carpal tunnel syndrome (CTS) associated with rheumatoid arthritis (RA) and idiopathic CTS have distinct ultrasound patterns. • The most characteristic sonographic features of CTS in RA patients are those indicative of synovial tissue inflammation at carpal tunnel level. Conversely, marked median nerve swelling is the dominant finding in idiopathic CTS. • Intraneural power Doppler signal is a frequent finding in both conditions. • In patients with CTS, differently from electrophysiology, US can provide clues prompting a rheumatology referral in case of prominent inflammatory findings at carpal tunnel level.


Assuntos
Artrite Reumatoide , Síndrome do Túnel Carpal , Artrite Reumatoide/complicações , Artrite Reumatoide/diagnóstico por imagem , Síndrome do Túnel Carpal/diagnóstico por imagem , Humanos , Nervo Mediano/diagnóstico por imagem , Ultrassonografia , Punho/diagnóstico por imagem
10.
Front Med (Lausanne) ; 7: 204, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32582725

RESUMO

Objective: To determine the prevalence of grey scale and power Doppler (PD) ultrasound (US) features of A1 pulley inflammation in a cohort of psoriatic arthritis (PsA) patients compared with rheumatoid arthritis (RA) patients. Methods: Sixty patients (30 with PsA and 30 with RA) were consecutively enrolled. The main clinimetric indexes were recorded, and US assessment of A1 pulleys from second to fifth fingers bilaterally was carried out. The presence of A1 pulley inflammation, defined as PD signal within a thickened pulley, was registered. Results: A1 pulley inflammation was found in 15 of 240 fingers (6.3%) of eight PsA patients (26.7%) and in one of 240 fingers (0.4%) of one RA patient (3.3%) (p < 0.01 and p = 0.03, respectively). Seven of eight PsA patients (88%) with at least one inflamed A1 pulley had a moderate/high disease activity score. The regression linear analysis (R 2 = 0.36, adjusted R 2 = 0.31) showed that A1 pulley inflammation was correlated with Disease Activity Index for Psoriatic Arthritis (DAPSA) (ß = 0.43, p = 0.03). Conclusion: US A1 pulley inflammation appears to be relatively common at patient level in PsA, seems to be a characteristic feature of PsA compared to RA, and correlates with DAPSA.

11.
Joint Bone Spine ; 87(6): 611-617, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32438060

RESUMO

OBJECTIVES: To investigate the diagnostic accuracy of ultrasound and conventional radiography in the evaluation of calcium pyrophosphate crystal deposits at wrist level. METHODS: Consecutive patients with a "definite" diagnosis of calcium pyrophosphate deposition disease and disease-controls were prospectively included in this cross-sectional single-centre study. Scapho-lunate ligament, triangular fibrocartilage complex, and volar recess of the radio-lunate joint were explored using ultrasound, conventional radiography and computed tomography. RESULTS: Sixty one patients and 39 disease controls were enrolled. Two-hundred wrists were evaluated using both conventional radiography and ultrasound and 26 using computed tomography. Ultrasound findings indicative of crystal deposits were found in at least one wrist in 95.1% of patients and in 15.4% of controls (P<0.001). Scapho-lunate ligament calcifications were reported in 83.6% of patients and in 5.1% of controls (P<0.001). On conventional radiography, calcifications were found in at least one wrist in 72.1% of patients and in 0% of controls (P<0.001). Using the Ryan-McCarty criteria as a gold standard, sensitivity, specificity and diagnostic accuracy were 0.72 (0.59-0.83), 1.0 (0.91-1.0) and 0.83 (0.74-0.90) for conventional radiography and 0.95 (0.86-0.99), 0.85 (0.69-0.94) and 0.91 (0.84-0.96) for ultrasound. The agreement between ultrasound and computed tomography was substantial when assessing triangular fibrocartilage complex (kappa=0.70; 0.43-0.97) and scapho-lunate ligament (kappa=0.69; 0.41-0.97), and moderate for radio-lunate joint (kappa=0.46; 0.12-0.80). CONCLUSIONS: This study supports the diagnostic accuracy of ultrasound in evaluating wrist involvement in calcium pyrophosphate deposition disease. The inclusion of the scapho-lunate ligament in a disease-oriented scanning protocol could improve the diagnostic performance of ultrasound.


Assuntos
Condrocalcinose , Punho , Pirofosfato de Cálcio , Condrocalcinose/diagnóstico por imagem , Estudos Transversais , Humanos , Ligamentos/diagnóstico por imagem , Articulação do Punho/diagnóstico por imagem
12.
Clin Exp Rheumatol ; 35(4): 647-652, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28339356

RESUMO

OBJECTIVES: To compare the diagnostic accuracy of musculoskeletal ultrasound (MSUS) and x-ray in evaluating wrist triangular fibrocartilage complex (TFCC) in patients with calcium pyrophosphate dihydrate deposition disease (CPPD) and to investigate the agreement between the extent of the calcium pyrophosphate dihydrate (CPP) crystal deposits assessed by MSUS and the radiographic findings. METHODS: We enrolled 84 patients: 36 patients with "definite" CPPD and 48 controls. The Ryan and McCarty diagnostic criteria were used. A rheumatologist performed bilateral MSUS examinations of the TFCC in all patients, assessing both the presence and absence of CCP crystals deposits and their extent (0-3; 0: absent; 1: 1-2 spots; 2: more than two spots covering <50% of the volume of the structure; 3: deposits covering >50% of the volume of the structure). A radiologist evaluated the presence/absence of x-ray calcifications at TFCC level in both groups. RESULTS: MSUS and x-ray sensitivity was 77.8% and 76.4%, respectively, whereas MSUS and x-ray specificity was 90.6% and 96.9%, respectively. Total agreement between MSUS and radiographic findings indicative of calcifications at TFCC level was 88.7%. CONCLUSIONS: This study supports the diagnostic accuracy of MSUS and x-ray in evaluating TFCC crystal deposits in patients with CPPD. Sensitivity and specificity of MSUS and x-ray resulted comparable. The highest MSUS score of the extent of the deposits correlated better with x-ray findings.


Assuntos
Condrocalcinose/diagnóstico por imagem , Fibrocartilagem Triangular/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Sensibilidade e Especificidade , Ultrassonografia , Articulação do Punho/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA