Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 53(3): 497-503, 2022 May.
Artigo em Chinês | MEDLINE | ID: mdl-35642161

RESUMO

Objective: To explore the feasibility of single-breath-hold compressed sensing real-time cine imaging (CS-cine) in the assessment of ventricular function and left ventricular (LV) strain. Methods: A total of 70 subjects were enrolled prospectively, and all subjects underwent cardiac magnetic resonance imaging (cardiac MRI) using both the standard steady-state free procession cine (sta-cine) acquisition and a prototype CS-cine sequence. For both CS-cine and sta-cine imaging, continuous short-axis cine images were acquired from the base to the apex to cover the entire left ventricle, and long-axis cine images including two-, three-, and four-chamber views were also acquired. The scanning range, number of slices, slice thickness and intervals were kept identical for the two cine images of the same participant. Subjective evaluation of the image quality was performed on all cine images. For both sequences, the conventional function parameters of the left and the right ventricles and LV strain values were assessed with post-processing software analysis. The cine image quality, conventional ventricular function parameters, and LV strain values were compared between the two cine groups and the differences were examined. Inter- and intraobserver agreements for CS-cine images were measured using intraclass correlation coefficient ( ICC). Bland-Altman analysis was performed to assess reproducibility between the two cine methods. Results: The median scanning time of CS-cine was 21 s versus 272 s for sta-cine ( P<0.001). The median image quality scores of two groups were significantly different, 4 points for sta-cine and 2 points for CS-cine ( P<0.001). Bi-ventricular end-diastolic volumes (EDV), stroke volume (SV) and ejection fraction (EF) were significantly smaller in CS-cine ( P<0.001). Nevertheless, no significant differences between the two groups in bi-ventricular ESV or LV mass were observed ( P>0.05). LV strain parameters, including the peak radial strain, peak circumferential strain and peak longitudinal strain derived from LV mid-ventricular slice, were significantly different in the two sequences ( P<0.001). Moreover, CS-cine-derived functional parameters and strain measurements have a good correlation with those of sta-cine (for RV function parameters, and left ventricular PLS, PCS values, more than 95% points fell within the limits of agreement [ LoA]; meanwhile, more than 91% points fell within the LoA for other parameters) and inter- and intraobserver agreements were strong ( ICC=0.88 to 0.99) for CS-cine. Conclusion: CS-cine can well realize the rapid acquisition of cine images for quantitative analysis of cardiac function, and the conventional ventricular function parameters and LV globalized strain values obtained from CS-cine imaging have good reproducibility.


Assuntos
Ventrículos do Coração , Imagem Cinética por Ressonância Magnética , Estudos de Viabilidade , Ventrículos do Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Imagem Cinética por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Reprodutibilidade dos Testes , Função Ventricular Esquerda
2.
Sci Rep ; 9(1): 11656, 2019 08 12.
Artigo em Inglês | MEDLINE | ID: mdl-31406129

RESUMO

To evaluate the value of dual-source computed tomography (DSCT) compared with transthoracic echocardiography (TTE) in assessing intracardiac and extracardiac anomalies in patients with coarctation of aorta (CoA) and interrupted aortic arch (IAA). Seventy-five patients (63 with CoA and 12 with IAA) who received preoperative DSCT and TTE were retrospectively studied. Intracardiac and extracardiac anomalies were recorded and compared by DSCT and TTE, in reference to surgical or cardiac catheterization findings. A total of 155 associated anomalies were finally found. Collateral circulation (56, 74.70%), patent ductus arteriosus (PDA; 41, 54.67%) were the most common anomalies. PDA, aortopulmonary window, and collateral circulation were more frequently present in patients with IAA than those with CoA (100% vs. 46.03%, 16.67% vs. 0%, and 100% vs. 69.84%, respectively, all p < 0.05). DSCT was superior to TTE in assessing associated extracardiac-vascular anomalies (sensitivity: 100% vs. 39.81%; specificity: 100% vs. 100%; positive predictive value: 100% vs. 100%; negative predictive value: 100% vs. 76.06%). Extracardiac-vascular anomalies, including collateral circulation and PDA, were the most common anomalies in patients with IAA and CoA. Compared with TTE, DSCT is more reliable in providing an overall preoperative evaluation of morphological features and extracardiac anomalies for surgical planning.


Assuntos
Aorta Torácica/diagnóstico por imagem , Coartação Aórtica/complicações , Defeito do Septo Aortopulmonar/epidemiologia , Permeabilidade do Canal Arterial/epidemiologia , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Aorta Torácica/anormalidades , Coartação Aórtica/diagnóstico por imagem , Defeito do Septo Aortopulmonar/complicações , Defeito do Septo Aortopulmonar/diagnóstico por imagem , Cateterismo Cardíaco/estatística & dados numéricos , Criança , Pré-Escolar , Circulação Colateral , Permeabilidade do Canal Arterial/complicações , Permeabilidade do Canal Arterial/diagnóstico por imagem , Ecocardiografia/estatística & dados numéricos , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Adulto Jovem
3.
BMC Cardiovasc Disord ; 17(1): 285, 2017 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-29202750

RESUMO

BACKGROUND: To investigate the diagnostic value of dual-source computed tomography (DSCT) in the evaluation of tetralogy of Fallot (TOF)-associated extracardiac vascular abnormalities in pediatric patients compared with transthoracic echocardiography (TTE). METHODS: One hundred and twenty-three pediatric patients diagnosed with TOF were included in this retrospective study. All patients underwent DSCT and TTE preoperatively. All associated extracardiac vascular abnormalities and their percentages were recorded. The diagnostic performances of DSCT and TTE were compared based on the surgical results. The image quality of DSCT was rated, and the effective radiation dose (ED) was calculated. RESULTS: A total of 159 associated extracardiac vascular deformities were confirmed by surgery. Patent ductus arteriosus (36, 22.64%), right-sided aortic arch (29, 18.24%), and pulmonary valve stenosis (23, 14.47%) were the most common associated extracardiac vascular abnormalities. DSCT was superior to TTE in demonstrating associated extracardiac anomalies (diagnostic accuracy: 99.13% vs. 97.39%; sensitivity: 92.45% vs. 77.07%; specificity: 99.81% vs. 99.42%). The agreement on grading the image quality of DSCT was excellent (κ = 0.80), and the mean score of the image quality was 3.39 ± 0.50. The mean ED of DSCT was 0.86 ± 0.47 mSv. CONCLUSIONS: Compared to TTE, low-dose DSCT has high diagnostic accuracy in the depiction of associated extracardiac vascular anomalies in pediatric patients with TOF, and could provide more morphological details for surgeons.


Assuntos
Ecocardiografia , Doses de Radiação , Tetralogia de Fallot/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Malformações Vasculares/diagnóstico por imagem , Fatores Etários , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Valor Preditivo dos Testes , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco , Tomografia Computadorizada por Raios X/efeitos adversos
4.
PLoS One ; 12(11): e0187578, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29155835

RESUMO

PURPOSE: To determine the value of dual-source computed tomography (DSCT) in depicting the morphological characteristics and diagnosing the associated malformations for patients with transposition of the great arteries (TGA) before surgery. MATERIALS AND METHODS: Twenty-five patients with TGA who underwent DSCT and transthoracic echocardiography (TTE) examination were retrospectively reviewed. The morphological types of TGA, the spatial relationship between the pulmonary artery and the aorta, as well as coronary artery-associated abnormalities were assessed by DSCT. In contrast to TTE, the diagnostic accuracy of associated malformations on DSCT were analyzed and calculated with reference to surgical or digital subtraction angiography (DSA) findings. Effective doses (EDs) were also calculated. RESULTS: Among the 25 patients, 12 (48%) had ventricular septal defects and left ventricular outflow tract stenosis. Sixteen patients (16/25, 64%) had great arteries with an oblique spatial relationship on DSCT. In addition, we found seven patients (7/25, 28%) with coronary artery malformation, including five with an abnormal coronary origin and two with signs of a myocardial bridge. According to DSA or surgical findings, DSCT was superior to TTE in demonstrating extracardiac anomalies (sensitivity, anomalies of great vessels: 100% vs. 93.33%, other anomalies: 100% vs. 46.15%). The mean estimated ED for those aged <10 years was <2 mSv (1.59 ± 0.95 mSv). CONCLUSIONS: DSCT can achieve an overall assessment of patients with TGA, including any associated malformations as well as the identification of the spatial relationship of the great arteries. DSCT can therefore be considered as an alternative imaging modality for surgical decision making.


Assuntos
Angiografia por Tomografia Computadorizada , Comunicação Interventricular/diagnóstico por imagem , Transposição dos Grandes Vasos/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Adolescente , Adulto , Aorta/diagnóstico por imagem , Aorta/fisiopatologia , Criança , Pré-Escolar , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Ecocardiografia/métodos , Feminino , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/fisiopatologia , Cardiopatias Congênitas/cirurgia , Comunicação Interventricular/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Lactente , Masculino , Ponte Miocárdica/diagnóstico por imagem , Ponte Miocárdica/fisiopatologia , Transposição dos Grandes Vasos/fisiopatologia , Transposição dos Grandes Vasos/cirurgia , Obstrução do Fluxo Ventricular Externo/fisiopatologia
5.
Eur J Radiol ; 89: 20-26, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28267539

RESUMO

PURPOSE: The aim of this study was to clarify the feasibility of myocardial strain using cardiovascular magnetic resonance (CMR) for the evaluation of left ventricular (LV) deformation in patients with Ebstein's anomaly (EA). MATERIALS AND METHODS: We recruited 32 patients with EA and 30 controls for CMR examination and measured LV function, dimension and tissue tracking parameters (the global and regional radial, circumferential and longitudinal peak strain), together with the right ventricle (RV) dimension. LV strain parameters were compared among the controls, patients with preserved LV ejection fraction (LVEF; ≥55%), and patients with reduced LVEF (<55%). Pearson's correlation was used to evaluate relationships between tissue tracking parameters with the RVEDD/LVEDD index and LVEF. An ROC analysis was also performed to determine whether the cut-off values for PS could be used to differentiate LV dysfunction between patients with EA and controls. The intraclass correlation coefficient (ICC) was used to assess the inter- and intra-observer variability. RESULTS: The global strain parameters all decreased significantly in the EA group compared with the control group (all P<0.05). Furthermore, the global radial and circumferential peak strain (PS) were obviously even lower in the reduced LVEF group than the strain measured in preserved LVEF groups (28.64% vs. 37.39%, p<0.05; and -8.20% vs. -17.89%; p<0.05; respectively). The regional strain abnormalities in EA patients were mainly involved in basal and middle segments. The results also demonstrated a significant correlation between the ratio of the RV end-diastolic dimension to the LV end-diastolic dimension (RVEDD/LVEDD index) with the global circumferential PS (r=0.508) and the longitudinal PS (r=0.474), as well as a good correlation between radial PS and LVEF (r=0.465). The ICCs for intra- and inter-observer variability were 0.797-0.904 and 0.701-0.896. CONCLUSIONS: LV strain serves an earlier and more comprehensive measurement of LV dysfunction than LVEF in EA, which could potentially be included as a supplementary diagnostic procedure in the evaluation of EA.


Assuntos
Anomalia de Ebstein/complicações , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Imageamento por Ressonância Magnética , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/patologia , Adulto , Anomalia de Ebstein/patologia , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Curva ROC , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA