1.
EuroIntervention ; 17(18): 1498-1505, 2022 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-34647890

RESUMO

BACKGROUND: Fractional flow reserve (FFR)-guided percutaneous coronary intervention (PCI) is superior to angiography-guided PCI. The clinical uptake of FFR has been limited, however, by the need to advance a wire in the coronary artery, the additional time required and the need for hyperaemic agents which can cause patient discomfort. FFR derived from routine coronary angiography eliminates these issues. AIMS: The aim of this study was to assess the diagnostic performance and accuracy of three-dimensional quantitative coronary angiography (3D-QCA)-based vessel FFR (vFFR) compared to pressure wire-based FFR (≤0.80). METHODS: The FAST II (Fast Assessment of STenosis severity) study was a prospective observational multicentre study designed to evaluate the diagnostic accuracy of vFFR compared to the reference standard (pressure wire-based FFR ≤0.80). A total of 334 patients from six centres were enrolled. Both site-determined and blinded independent core lab vFFR measurements were compared to FFR. RESULTS: The core lab vFFR was 0.83±0.09 and pressure wire-based FFR 0.83±0.08. A good correlation was found between core lab vFFR and pressure wire-based FFR (R=0.74; p<0.001; mean bias 0.0029±0.0642). vFFR had an excellent diagnostic accuracy in identifying lesions with an invasive wire-based FFR ≤0.80 (area under the curve [AUC] 0.93; 95% confidence interval [CI]: 0.90-0.96; p<0.001). Positive predictive value, negative predictive value, diagnostic accuracy, sensitivity and specificity of vFFR were 90%, 90%, 90%, 81% and 95%, respectively. CONCLUSIONS: 3D-QCA-based vFFR has excellent diagnostic performance to detect FFR ≤0.80. The study was registered on clinicaltrials.gov under identifier NCT03791320.


Assuntos
Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Constrição Patológica , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico , Vasos Coronários/diagnóstico por imagem , Humanos , Valor Preditivo dos Testes , Estudos Prospectivos , Índice de Gravidade de Doença
2.
Catheter Cardiovasc Interv ; 97(4): E495-E501, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32725862

RESUMO

OBJECTIVES: We aimed to evaluate the feasibility of using three dimensional-quantitative coronary angiography (3D-QCA) based fractional flow reserve (FFR) (vessel fractional flow reserve [vFFR], CAAS8.1, Pie Medical Imaging) and to correlate vFFR values with intravascular ultrasound (IVUS) for the evaluation of intermediate left main coronary artery (LMCA) stenosis. BACKGROUND: 3D-QCA derived FFR indices have been recently developed for less invasive functional lesion assessment. However, LMCA lesions were vastly under-represented in first validation studies. METHODS: This observational single-center cohort study enrolled consecutive patients with stable angina, unstable angina, or non-ST-segment elevation myocardial infarction and nonostial, intermediate grade LMCA stenoses who underwent IVUS evaluation. vFFR was computed based on two angiograms with optimal LMCA stenosis projection and correlated with IVUS-derived minimal lumen area (MLA). RESULTS: A total of 256 patients with intermediate grade LMCA stenosis evaluated with IVUS were screened for eligibility; 147 patients met the clinical inclusion criteria and had a complete IVUS LMCA footage available, of them, 63 patients (63 lesions) underwent 3D-QCA and vFFR analyses. The main reason for screening failure was insufficient quality of the angiogram (51 patients,60.7%). Mean age was 65 ± 11 years, 75% were male. Overall, mean MLA within LMCA was 8.77 ± 3.17 mm2 , while mean vFFR was 0.87 ± 0.09. A correlation was observed between vFFR and LMCA MLA (r = .792, p = .001). The diagnostic accuracy of vFFR ≤0.8 in identifying lesions with MLA < 6.0 mm2 (sensitivity 98%, specificity 71.4%, area under the curve (AUC) 0.95, 95% confidence interval (CI) 0.89-1.00, p = .001) was good. CONCLUSIONS: In patients with good quality angiographic visualization of LMCA and available complete LMCA IVUS footage, 3D-QCA based vFFR assessment of LMCA disease correlates well to LMCA MLA as assessed by IVUS.


Assuntos
Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Estudos de Coortes , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Humanos , Masculino , Valor Preditivo dos Testes , Índice de Gravidade de Doença , Resultado do Tratamento , Ultrassonografia de Intervenção
3.
Catheter Cardiovasc Interv ; 96(6): 1156-1171, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-31883294

RESUMO

BACKGROUND: Residual stent strut thrombosis after primary percutaneous coronary intervention (PCI), negatively affects myocardial perfusion, may increase stent thrombosis risk, and it is associated with neointima hyperplasia at follow-up. OBJECTIVES: To study the effectiveness of any bivalirudin infusion versus unfractionated heparin (UFH) infusion in reducing residual stent strut thrombosis in patients with ST-elevation myocardial infarction (STEMI). METHODS: Multi-vessel STEMI patients undergoing primary PCI and requiring staged intervention were selected among those randomly allocated to two different bivalirudin infusion regimens in the MATRIX (Minimizing Adverse Haemorrhagic Events by TRansradial Access Site and angioX) Treatment-Duration study. Those receiving heparin only were enrolled into a registry arm. Optical coherence tomography (OCT) of the infarct-related artery was performed at the end of primary PCI and 3-5 days thereafter during a staged intervention. The primary endpoint was the change in minimum flow area (ΔMinFA) defined as (stent area + incomplete stent apposition [ISA] area) - (intraluminal defect + tissue prolapsed area) between the index and staged PCI. RESULTS: 123 patients in bivalirudin arm and 28 patients in the UFH arm were included. Mean stent area, percentage of malapposed struts, and mean percent thrombotic area were comparable after index or staged PCI. The ΔMinFA in the bivalirudin group was 0.25 versus 0.05 mm2 in the UFH group, which resulted in a between-group significant difference of 0.36 [95% CI: (0.05, 0.71); p = .02]. This was mostly related to a decrease in tissue protrusion in the bivalirudin group (p = .03). There was a trend towards more patients in the bivalirudin group who achieved a 5% difference in the percentage of OCT frames with the area >5% (p = .057). CONCLUSIONS: The administration of bivalirudin after primary PCI significantly reduces residual stent strut thrombosis when compared to UFH. This observation should be considered hypothesis-generating since the heparin-treated patients were not randomly allocated.


Assuntos
Anticoagulantes/administração & dosagem , Antitrombinas/administração & dosagem , Trombose Coronária/terapia , Heparina/administração & dosagem , Hirudinas/administração & dosagem , Fragmentos de Peptídeos/administração & dosagem , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Tomografia de Coerência Óptica , Idoso , Anticoagulantes/efeitos adversos , Antitrombinas/efeitos adversos , Trombose Coronária/diagnóstico por imagem , Feminino , Hemorragia/induzido quimicamente , Heparina/efeitos adversos , Hirudinas/efeitos adversos , Humanos , Infusões Parenterais , Itália , Masculino , Pessoa de Meia-Idade , Neointima , Fragmentos de Peptídeos/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Valor Preditivo dos Testes , Estudos Prospectivos , Proteínas Recombinantes/administração & dosagem , Proteínas Recombinantes/efeitos adversos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Stents , Fatores de Tempo , Resultado do Tratamento
4.
IEEE Trans Med Imaging ; 37(7): 1618-1625, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29969412

RESUMO

Intravascular polarimetry with polarization sensitive optical frequency domain imaging (PS-OFDI) measures polarization properties of the vessel wall and offers characterization of coronary atherosclerotic lesions beyond the cross-sectional image of arterial microstructure available to conventional OFDI. A previous study of intravascular polarimetry in cadaveric human coronary arteries found that tissue birefringence and depolarization provide valuable insight into key features of atherosclerotic plaques. In addition to various tissue components, catheter and sample motion can also influence the polarization of near infrared light as used by PS-OFDI. This paper aimed to evaluate the robustness and repeatability of imaging tissue birefringence and depolarization in a clinical setting. 30 patients scheduled for percutaneous coronary intervention at the Erasmus Medical Center underwent repeated PS-OFDI pullback imaging, using commercial imaging catheters in combination with a custom-built PS-OFDI console. We identified 274 matching cross sections among the repeat pullbacks to evaluate the reproducibility of the conventional backscatter intensity, the birefringence, and the depolarization signals at each spatial location across the vessel wall. Bland-Altman analysis revealed best agreement for the birefringence measurements, followed by backscatter intensity, and depolarization, when limiting the analysis to areas of meaningful birefringence. Pearson correlation analysis confirmed highest correlation for birefringence (0.86), preceding backscatter intensity (0.83), and depolarization (0.78). Our results demonstrate that intravascular polarimetry generates robust maps of tissue birefringence and depolarization in a clinical setting. This outcome motivates the use of intravascular polarimetry for future clinical studies that investigate polarization properties of arterial atherosclerosis.


Assuntos
Procedimentos Endovasculares/métodos , Imagem Óptica/métodos , Birrefringência , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Pessoa de Meia-Idade , Intervenção Coronária Percutânea , Placa Aterosclerótica/diagnóstico por imagem , Reprodutibilidade dos Testes
5.
J Cardiol ; 72(2): 149-154, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29478878

RESUMO

BACKGROUND AND AIMS: Significant left main (LM) stem disease is potentially life-threatening and mandates revascularization. This study aimed to assess how patients rate the importance of particular features of coronary artery bypass grafting (CABG) and percutaneous coronary intervention (PCI), how this determines their preference for a particular treatment strategy, and whether particular personality characteristics influence this preference. METHODS AND RESULTS: In total, 1145 patients who visited the outpatient clinic of the Erasmus Medical Center for stable coronary artery disease were asked to complete a case vignette-questionnaire on a hypothetical significant LM stenosis amenable to PCI or CABG. To assess the individual's personality disposition and general distress level, each patient had to complete a set of 3 standardized, validated questionnaires with satisfactory psychometric properties. Overall 89% of patients preferred PCI to CABG. PCI was the preferred strategy despite a higher risk for repeat revascularization and need for more medication. Remarkably, the fact that a risk for repeat revascularization is more common in the PCI group is less important for the patients who opt for PCI. Risk for stroke and bleeding were the most important arguments to opt for PCI over CABG. Type D personality, depression, and anxiety were all associated with a relatively higher preference for CABG as revascularization strategy. CONCLUSION: Overall, when given the choice patients seem to have a clear preference for PCI over CABG and consider stroke and bleeding important procedure-related complications. Patients with Type D personality, depression, or anxiety favor CABG.


Assuntos
Ponte de Artéria Coronária , Doença da Artéria Coronariana/cirurgia , Preferência do Paciente , Intervenção Coronária Percutânea , Adulto , Idoso , Idoso de 80 Anos ou mais , Ansiedade , Ponte de Artéria Coronária/efeitos adversos , Depressão , Feminino , Hemorragia/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Risco , Acidente Vascular Cerebral/etiologia , Inquéritos e Questionários , Resultado do Tratamento , Personalidade Tipo D
6.
Int J Cardiol ; 233: 80-84, 2017 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-28161129

RESUMO

OBJECTIVES: To assess whether the RXi Navvus system compared to the use of standard Fractional Flow Reserve (FFR) wires reduces total contrast volume, radiation and overall study cost in a real world patient population referred for coronary angiography or percutaneous coronary intervention. BACKGROUND: FFR is the mainstay of functional hemodynamic assessment of coronary artery lesions. The RXi Navvus system (ACIST Medical Systems, Eden Prairie, MN) is a monorail microcatheter with FFR-measurement capability through optical pressure sensor technology. METHODS: This is an investigator-initiated, prospective, single-center, observational cohort study. A total of 238 patients were enrolled, 97 patients with Navvus and 141 with conventional pressure-wire based FFR (PW-FFR). Final analyses were performed on the cohort in which only 1 device was used (82 Navvus procedures vs. 136 PW-FFR procedures). RESULTS: No significant differences were found in the total amount of contrast used (150±77 vs 147±79ml; p=0.81), radiation use (6200±4601 vs. 5076±4655 centiG∗cm2; p=0.09) or costs (€1994,- vs. €1930,-; p=0.32) in the Navvus vs. PW-FFR groups respectively. CONCLUSIONS: No significant differences were found in the amount of contrast used, total procedural costs or radiation when the Navvus system was used as compared to conventional FFR wires. CONDENSED ABSTRACT: CONTRACT is an investigator-initiated, prospective, single-center, observational cohort study that evaluated whether the RXi Navvus system compared to the use of standard Fractional Flow Reserve (FFR) wires reduces total contrast volume, radiation and overall study cost in a real world patient population referred for coronary angiography or percutaneous coronary intervention. Use of the RXi Navvus system was associated with comparable procedural costs, amount of radiation and contrast used as compared to PW-FFR systems.


Assuntos
Cateteres Cardíacos/economia , Angiografia Coronária/instrumentação , Estenose Coronária/cirurgia , Vasos Coronários/cirurgia , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea/instrumentação , Angiografia Coronária/economia , Estenose Coronária/economia , Estenose Coronária/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Análise Custo-Benefício , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Miniaturização , Intervenção Coronária Percutânea/economia , Estudos Prospectivos
7.
Int J Cardiol ; 220: 802-8, 2016 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-27394977

RESUMO

BACKGROUND: The hypothesized increased thrombus entrapment during bioresorbable vascular scaffold implantation in acute myocardial infarction, the so-called "snowshoe effect" has never been demonstrated. METHODS: Patients enrolled in the BVS STEMI FIRST study matched with STEMI patients implanted with everolimus-eluting metal stents (EES) and undergoing optical coherence tomography (OCT) at the index procedure were compared. Quantitative coronary angiography analysis and optical coherence tomography data for evaluation of thrombotic prolapse were reported. Percentage maximal footprint (%MFP) analysis as an indicator of the snowshoe effect was performed. RESULTS: A total of 302 patients were analyzed (151 with BVS and 151 with EES). Of those patients 30 implanted with BVS and 17 implanted with EES were imaged at the index procedure with OCT. Baseline clinical characteristics, TIMI-flow and thrombus burden were similar between groups. Aspiration thrombectomy was similarly performed in the two groups (BVS 83.3% vs 94.1% EES, p=0.405). At the end of the procedure, final TIMI 3 flow was achieved in 93.3% and 82.4% of BVS and EES patients respectively (p=0.296). The %MFP was significantly higher in the BVS treated patients (36.59±5.65% vs 17.61±4.30, p<0.001). The results of the OCT analysis showed a mean prolapse area (0.61±0.26mm(2) vs 0.90±0.31mm(2), p=0.001) and a percentage prolapse area (7.11±2.98mm(2) vs 9.98±2.90mm(2), p=0.002) significantly higher in the EES group. CONCLUSIONS: Scaffold structural characteristics such as strut width may play a role in terms of thrombus dislodgment patterns and acute prolapsing material.


Assuntos
Implantes Absorvíveis/tendências , Stents Farmacológicos/tendências , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Trombose/diagnóstico por imagem , Alicerces Teciduais/tendências , Implantes Absorvíveis/efeitos adversos , Adulto , Idoso , Efeitos Psicossociais da Doença , Stents Farmacológicos/efeitos adversos , Everolimo/administração & dosagem , Estudos de Viabilidade , Feminino , Humanos , Masculino , Metais/efeitos adversos , Pessoa de Meia-Idade , Trombose/etiologia , Alicerces Teciduais/efeitos adversos , Tomografia de Coerência Óptica/tendências , Resultado do Tratamento
10.
Cardiovasc Ultrasound ; 11: 25, 2013 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-23870248

RESUMO

PURPOSE: To evaluate the atherosclerotic evolution in coronary bifurcations located proximally and distally to a bioresorbable scaffold. METHODS: Thirty bifurcations located >5 mm beyond the scaffolded segment, being investigated with serial intravascular ultrasound virtual histology (IVUS-VH) examinations, at baseline and 2-years, in patients enrolled in the ABSORB cohort B1 study were included in this analysis. In each bifurcation, the frames portraying the proximal rim, in-bifurcation, and distal rim of the ostium of the side branch were analyzed. The geometric parameters and plaque types were evaluated at baseline and 2-years follow-up. RESULTS: There were no significant differences in the geometrical parameters such as lumen, vessel and plaque areas as well as in the composition of the atheroma between baseline and 2-years follow-up.When we separately examined the bifurcations located proximally and distally to the scaffolded segment, no changes were found at the distal bifurcations, while at the proximal bifurcations there was a statistical significant decrease in the plaque burden (36.67 ± 13.33% at baseline vs. 35.06 ± 13.20% at 2 years follow-up, p = 0.04).Ten necrotic core rich plaques were found at baseline, of which 2 regressed to either fibrotic plaque or to intimal thickening at 2 years follow-up. The other 8 did not change. Disease progression was noted in 3 plaques (1 adaptive intimal thickening, 1 fibrotic and 1 fibrocalcific plaque) that evolved to necrotic rich plaques. CONCLUSIONS: Plaque regression was noted at the bifurcations located proximally to the bioresorbable scaffold but not at these located distally. Additional studies are required to confirm this finding and examine further the effect of drug elution on atherosclerotic evolution.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Ecocardiografia/métodos , Sirolimo/análogos & derivados , Ultrassonografia de Intervenção/métodos , Idoso , Estenose Coronária , Everolimo , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imunossupressores/administração & dosagem , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Sirolimo/administração & dosagem , Técnica de Subtração , Resultado do Tratamento , Interface Usuário-Computador
12.
EuroIntervention ; 9(6): 709-20, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23628499

RESUMO

AIMS: To assess serially the edge vascular response (EVR) of a bioresorbable vascular scaffold (BVS) compared to a metallic everolimus-eluting stent (EES). METHODS AND RESULTS: Non-serial evaluations of the Absorb BVS at one year have previously demonstrated proximal edge constrictive remodelling and distal edge changes in plaque composition with increase of the percent fibro-fatty (FF) tissue component. The 5 mm proximal and distal segments adjacent to the implanted devices were investigated serially with intravascular ultrasound (IVUS), post procedure, at six months and at two years, from the ABSORB Cohort B1 (n=45) and the SPIRIT II (n=113) trials. Twenty-two proximal and twenty-four distal edge segments were available for analysis in the ABSORB Cohort B1 trial. In the SPIRIT II trial, thirty-three proximal and forty-six distal edge segments were analysed. At the 5-mm proximal edge, the vessels treated with an Absorb BVS from post procedure to two years demonstrated a lumen loss (LL) of 6.68% (-17.33; 2.08) (p=0.027) with a trend toward plaque area increase of 7.55% (-4.68; 27.11) (p=0.06). At the 5-mm distal edge no major changes were evident at either time point. At the 5-mm proximal edge the vessels treated with a XIENCE V EES from post procedure to two years did not show any signs of LL, only plaque area decrease of 6.90% (-17.86; 4.23) (p=0.035). At the distal edge no major changes were evident with regard to either lumen area or vessel remodelling at the same time point. CONCLUSIONS: The IVUS-based serial evaluation of the EVR up to two years following implantation of a bioresorbable everolimus-eluting scaffold shows a statistically significant proximal edge LL; however, this finding did not seem to have any clinical implications in the serial assessment. The upcoming imaging follow-up of the Absorb BVS at three years is anticipated to provide further information regarding the vessel wall behaviour at the edges.


Assuntos
Stents Farmacológicos , Everolimo , Implantes Absorvíveis , Seguimentos , Humanos , Masculino , Sirolimo/administração & dosagem , Resultado do Tratamento
13.
JACC Cardiovasc Interv ; 5(6): 656-65, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22721662

RESUMO

OBJECTIVES: This study sought to investigate in vivo the vascular response at the proximal and distal edges of the second-generation ABSORB everolimus-eluting bioresorbable vascular scaffold (BVS). BACKGROUND: The edge vascular response after implantation of the BVS has not been previously investigated. METHODS: The ABSORB Cohort B trial enrolled 101 patients and was divided into B(1) (n = 45) and B(2) (n = 56) subgroups. The adjacent (5-mm) proximal and distal vessel segments to the implanted ABSORB BVS were investigated at either 6 months (B(1)) or 1 year (B(2)) with virtual histology intravascular ultrasound (VH-IVUS) imaging. RESULTS: At the 5-mm proximal edge, the only significant change was modest constrictive remodeling at 6 months (Δ vessel cross-sectional area: -1.80% [-3.18; 1.30], p < 0.05), with a tendency to regress at 1 year (Δ vessel cross-sectional area: -1.53% [-7.74; 2.48], p = 0.06). The relative change of the fibrotic and fibrofatty (FF) tissue areas at this segment were not statistically significant at either time point. At the 5-mm distal edge, a significant increase in the FF tissue of 43.32% [-19.90; 244.28], (p < 0.05) 1-year post-implantation was evident. The changes in dense calcium need to be interpreted with caution since the polymeric struts are detected as "pseudo" dense calcium structures with the VH-IVUS imaging modality. CONCLUSIONS: The vascular response up to 1 year after implantation of the ABSORB BVS demonstrated some degree of proximal edge constrictive remodeling and distal edge increase in FF tissue resulting in nonsignificant plaque progression with adaptive expansive remodeling. This morphological and tissue composition behavior appears to not significantly differ from the behavior of metallic drug-eluting stents at the same observational time points.


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Sirolimo/análogos & derivados , Alicerces Teciduais , Ultrassonografia de Intervenção , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Vasos Coronários/patologia , Everolimo , Feminino , Fibrose , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Sirolimo/administração & dosagem , Fatores de Tempo , Resultado do Tratamento , Calcificação Vascular/diagnóstico por imagem
14.
JACC Cardiovasc Imaging ; 4(7): 774-80, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21757169

RESUMO

OBJECTIVES: The aim of this study was to evaluate the progression of atherosclerotic coronary plaques at bifurcations, using combined intravascular ultrasound-virtual histology (IVUS-VH) and optical coherence tomography (OCT). BACKGROUND: Pathological findings reveal that atherosclerotic plaques characterized by the presence of large necrotic cores (NCs) with fibrous cap thicknesses < 65 µm are more prone to rupture. Accuracy in the detection of high-risk plaques could be improved by the combined use of IVUS-VH and OCT. METHODS: IVUS-VH and OCT are 2 imaging modalities with different lateral resolutions and different depths of penetration. To provide a precise matching of the images, bifurcations were used as landmarks. IVUS-VH and OCT were performed in 56 bifurcations from 24 patients at baseline and at 6-month follow-up. All patients were treated with standard medical therapy. Bifurcations were studied at the proximal, in-bifurcation, and distal regions. Plaques were classified according to their composition as assessed by IVUS-VH and fibrous cap thickness as quantified by OCT. RESULTS: At baseline, 27 NC-rich plaques were found. At 6-month follow-up, 22 (81%) did not show any significant change. Four new NC-rich lesions developed. At both time points, percent NC was higher and the fibrous cap was thinner at the proximal bifurcation rim compared with the distal. There were no significant changes in percent NC and fibrous cap thickness in the 3 bifurcation regions between baseline and follow-up examinations. No major cardiovascular events due to bifurcation lesion progression were observed. CONCLUSIONS: The combined use of IVUS-VH and OCT is a reliable tool to serially assess plaque progression and regression, and in the present study it was demonstrated to be safe and feasible. At 6-month follow-up, in this post-percutaneous coronary intervention patient population, most high-risk plaques remained unchanged, retaining their imaging classifications, nevertheless appearing to have remained clinically silent.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Tomografia de Coerência Óptica , Ultrassonografia de Intervenção , Idoso , Angioplastia Coronária com Balão/instrumentação , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Doença da Artéria Coronariana/terapia , Progressão da Doença , Estudos de Viabilidade , Feminino , Fibrose , Humanos , Masculino , Pessoa de Meia-Idade , Necrose , Países Baixos , Valor Preditivo dos Testes , Stents , Fatores de Tempo , Resultado do Tratamento
15.
Eur Heart J ; 32(3): 294-304, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21123276

RESUMO

AIMS: The first generation of the everolimus-eluting bioresorbable vascular scaffold (BVS 1.0) showed an angiographic late loss higher than the metallic everolimus-eluting stent Xience V due to scaffold shrinkage. The new generation (BVS 1.1) presents a different design and manufacturing process than the BVS 1.0. This study sought to evaluate the differences in late shrinkage, neointimal response, and bioresorption process between these two scaffold generations using optical coherence tomography (OCT). METHODS AND RESULTS: A total of 12 lesions treated with the BVS 1.0 and 12 selected lesions treated with the revised BVS 1.1 were imaged at baseline and 6-month follow-up with OCT. Late shrinkage and neointimal area (NIA) were derived from OCT area measurements. Neointimal thickness was measured in each strut. Strut appearance has been classified as previously described. Baseline clinical, angiographic, and OCT characteristics were mainly similar in the two groups. At 6 months, absolute and relative shrinkages were significantly larger for the BVS 1.0 than for the BVS 1.1 (0.98 vs. 0.07 mm² and 13.0 vs. 1.0%, respectively; P = 0.01). Neointimal area was significantly higher in the BVS 1.0 than in the BVS 1.1 (in-scaffold area obstruction of 23.6 vs. 12.3%; P < 0.01). Neointimal thickness was also larger in the BVS 1.0 than in the BVS 1.1 (166.0 vs. 76.4 µm; P < 0.01). Consequently, OCT, intravascular ultrasound, and angiographic luminal losses were higher with the BVS 1.0 than with the BVS 1.1. At 6 months, strut appearance was preserved in only 2.9% of the BVS 1.0 struts, but remained unchanged with the BVS 1.1 indicating different state of strut microstucture and/or their reflectivity. CONCLUSION: The BVS 1.1 has less late shrinkage and less neointimal growth at 6-month follow-up compared with the BVS 1.0. A difference in polymer degradation leading to changes in microstructure and reflectivity is the most plausible explanation for this finding.


Assuntos
Stents Farmacológicos/normas , Imunossupressores/administração & dosagem , Isquemia Miocárdica/diagnóstico por imagem , Sirolimo/análogos & derivados , Tomografia de Coerência Óptica/métodos , Idoso , Materiais Biocompatíveis/normas , Prótese Vascular/normas , Angiografia Coronária/métodos , Everolimo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/terapia , Desenho de Prótese , Falha de Prótese , Sirolimo/administração & dosagem , Alicerces Teciduais , Ultrassonografia de Intervenção