Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Clin Med ; 11(17)2022 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-36078941

RESUMO

Background: The aim of this study was to describe the value of the Odysight® application in addition to a classical follow-up regimen in the detection of exudative recurrences in patients with macular edema. Methods: We conducted an observational, multicenter, retrospective study. The Odysight® application includes a visual acuity (VA) test that can lead to alerts in case of a drop of >5 VA letters on two successive tests. The efficacy of the alerts in detecting exudative recurrence was studied. Results: A total of 149 eyes of 123 patients were included. The sensitivity of alerts for the detection of recurrence was 30.8% (95% CI [17.6; 44.0]) and its specificity was 83.7% (95% CI [73.2; 94.3]. A better baseline VA was found to be significantly associated with a better retention of the application (OR = 0.05, 95% CI [0.002; 0.62]; p = 0.045). Of the 12/39 alerts that detected a recurrence, eight (20.5% of all alerts) resulted in the scheduling or advancement of an intravitreal injection. Conclusions: In the present study, the sensitivity and positive predictive value of the Odysight® application seems low but its use in addition to the usual follow-up of the patient can detect, in certain cases, an early recurrence and thus allow an anticipated readjustment of the treatment.

2.
J Refract Surg ; 37(11): 759-766, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34756138

RESUMO

PURPOSE: To assess the impact of the use of artificial tears during the preoperative work-up performed before age-related cataract surgery, when a toric intraocular lens (IOL) was indicated. METHODS: This was a monocentric prospective study assessing 73 eyes of 51 patients, included consecutively after a preoperative work-up performed without artificial tears (no artificial tears group), when a toric IOL was indicated. Each included patient underwent a second series of examinations: biometry using the IOLMaster 700 (Carl Zeiss Meditec AG) and topography using the OPD-Scan II (Nidek), 1 minute after artificial tears instillation (artificial tears group; hyaluronate de sodium 0.15%, threalose 3% [Théalose; Théa]). Changes in anterior corneal astigmatism and subsequent changes in toric IOL calculation were analyzed. The error in predicted residual astigmatism was calculated. RESULTS: Anterior corneal astigmatism and total corneal astigmatism measured with the IOLMaster 700 were significantly modified when artificial tears were instilled before the examinations (1.51 ± 0.57 diopters [D], range: 0.75 to -3.55 vs 1.42 ± 0.63 D, range: 0.42 to 3.35 D; P = .043 and 1.59 ± 0.54 D, range: 0.87 to 3.48 vs 1.51 ± 0.59 D, range: 0.56 to 3.27 D, P = .038, respectively). This modification led to a change in IOL cylinder calculation in 43.8% of cases and to a change in implantation axis greater than 10° in 17.7% of cases. These changes were significantly greater in patients with a breakup time (BUT) less than 5 seconds (57.5% and 27.8%, with P = .009 and .029, respectively). In the subgroup of patients with a BUT of less than 5 seconds, the mean absolute error in predicted astigmatism was significantly lower after artificial tears instillation (0.48 ± 0.50 D, range: 0.00 to 2.79 vs 0.37 ± 0.25 D, range: 0.00 to 1.10 D, P = .048). CONCLUSIONS: Dry eye significantly impacted toric IOL calculations and should be taken into account during the preoperative assessments. Using artificial tears reduced the number of refractive errors. [J Refract Surg. 2021;37(11):759-766.].


Assuntos
Catarata , Facoemulsificação , Catarata/complicações , Topografia da Córnea , Humanos , Implante de Lente Intraocular , Lubrificantes Oftálmicos , Estudos Prospectivos , Refração Ocular , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA