Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Environ Radioact ; 272: 107359, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38147785

RESUMO

In this paper, we present a voxel-based phantom of Medaka fish that can be used to assess the internal radiation doses that would be absorbed by different organs of this fish species if exposed to radioactive wastewater released into the ocean. The geometric model for fish was generated based on available Wavefront Object files for smooth-bodied Medaka fish organs, whereas due to the lack of Medaka fish material specification, the material model was constructed using material data appropriate to ICRP 110 adult male voxel-based phantom. Absorbed Fractions (AFs) and Specific Absorbed Fractions (SAFs) were calculated for eight organs of major interest as sources and for each organ as target at a set of discrete photon, electron, alpha and neutron energies. To validate the present model the calculated AFs in the studied organs were compared to ones obtained in similar organs in a voxel-based phantom of another teleost fish species called Limanda limanda. The results presented are consistent with the reference dosimetric data. We concluded that the Medaka model can be used in radioecology research to improve marine radiation protection.


Assuntos
Oryzias , Monitoramento de Radiação , Animais , Masculino , Doses de Radiação , Radiometria/métodos , Radiação Ionizante , Imagens de Fantasmas , Fótons , Método de Monte Carlo , Simulação por Computador
2.
Jpn J Radiol ; 41(12): 1420-1430, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37454023

RESUMO

In the present work, a new Monte Carlo Geant4 based code called InterDosi 1.0, was used to simulate specific absorbed fractions (SAFs) in the six reference pediatric voxel-based phantoms developed by the International Commission on Radiological Protection (ICRP). The aim of this study was to assess the ability of this code to estimate SAFs in a variety of voxel-based phantoms. A large number of photon SAFs were calculated for pairs of organs corresponding to three sources and 170 target organs/regions. A total of 108 initial photons were uniformly emitted from the source organs with eight discrete energies. In order to speed up the calculation of SAFs, Monte Carlo multithreaded simulations were started on a workstation with 12 threads, and a Geant4 tracking optimization technique was applied that consists in skipping the voxel boundaries when two adjacent voxels share the same material, which seems to reduce the simulation time by an average of approximately 36%. The results showed good agreement with the reference data produced through the MCNP 2.7 code, with average and maximum absolute discrepancies of 0.5% and 7.68%, respectively. We concluded that these results confirm the feasibility of InterDosi code to perform photon internal dosimetry calculations at a voxel level.


Assuntos
Radiometria , Software , Humanos , Criança , Doses de Radiação , Radiometria/métodos , Simulação por Computador , Imagens de Fantasmas , Fótons , Método de Monte Carlo
3.
Radiol Phys Technol ; 16(2): 212-226, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36917405

RESUMO

Internal radiation exposure using radiopharmaceuticals, as in nuclear medicine procedures, necessitates the estimation of the S-value to determine and improve the estimates of absorbed doses in at-risk organs and tissues. The S value is defined as the absorbed dose in the target organ per unit of nuclear transformation in the source organ. It is calculated using the specific absorbed fraction, which is an important quantity that connects the deposited energy in the target and emitting source organs. In this study, we applied DoseCalcs, a new Geant4-based tool, to estimate the S values of [Formula: see text]F using nuclear data from ICRP Publication 107. Geometrical data from ICRP Publications 110 and 143 were used to select four models representing male and female phantoms for adults and 15 years old to study the variability in the S-values arising from variations in anatomy and initial energy validations, because we used the [Formula: see text] mean energy instead of the full beta spectrum. The [Formula: see text]F-released photons and [Formula: see text] from 26 source organs were tracked using the Geant4 Livermore package. Accordingly, the S-values were calculated for 141 target organs. The results for the adult male and female phantoms were compared with the OpenDose reference data. These results agreed well with OpenDose, the average ratio for self-absorption S-values was 1.015, and the average ratios for the cross-irradiation were 1.2 and 1.22 for the AM and AF, respectively. This indicates the accuracy of DoseCalcs for subsequent use in estimating [Formula: see text]F S-values using voxelized geometries.


Assuntos
Braquiterapia , Exposição à Radiação , Masculino , Humanos , Adulto , Feminino , Doses de Radiação , Fótons , Imagens de Fantasmas
4.
Radiat Environ Biophys ; 61(4): 623-629, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36173460

RESUMO

S-values are typically used to quantify internal doses of biota internally due to the incorporation of radionuclides. In this study, the InterDosi 1.0 Monte Carlo code was used to estimate S-values in five main organs of a crab phantom as well as in surrounding seawater for eleven radionuclides, namely 3H, 14C, 134Cs, 137Cs, 60Co, 125Sb, 90Sr, 129I, 99Tc, 106Ru, and 238Pu. After the Fukushima accident, these radionuclides have been detected in wastewater by the Japan Nuclear Regulatory Authority. In this work, S-values were calculated for all crab organs and the surrounding seawater. These values can be used in conjunction with any measured activities in water, to determine internal doses absorbed by crab organs. Furthermore, it is shown that for a self-absorption condition the studied radionuclides can be classified into five main categories, with 238Pu showing the highest S-values for any organ. Moreover, the results demonstrate that the obtained S-values decrease with increasing organ mass. In contrast, for a cross-absorption condition, the studied organs can be classified into seven main categories. In addition, by taking seawater as a source of irradiation, 238Pu had the highest cross-absorption S-values in two organs of particular biological relevance, the heart and gonads, when compared to the remaining radionuclides. It is concluded that due to the pre-calculated S-value database of a reference crab, it will become easier to use this organism as a bio indicator to study any radiation-induced effects on the marine environment.


Assuntos
Braquiúros , Acidente Nuclear de Fukushima , Exposição à Radiação , Monitoramento de Radiação , Poluentes Radioativos da Água , Animais , Águas Residuárias , Radioisótopos de Césio , Poluentes Radioativos da Água/análise , Japão , Monitoramento de Radiação/métodos
5.
Appl Radiat Isot ; 182: 110145, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35180525

RESUMO

The International Commission on Radiological Protection (ICRP) through its publications recommends the estimation of Specific Absorbed Fractions (SAFs) using voxelized phantoms in order to assess the doses internally absorbed by organs exposed to ionizing radiation. In the present work, we report a large set of SAFs calculated using the ICRP Adult Female (ICRP-AF) phantom. The new Geant4-based code called InterDosi version 1.0 was used to simulate monoenergetic electrons of 20 different energies, ranging from 0.005 to 10 MeV, emitted uniformly from 18 different source organs. In order to estimate SAFs in 169 target organs/regions, 360 Monte Carlo multithreaded simulations were run on 32 CPUs of the HPC-MARWAN-CNRST computing grid. The calculated SAFs were compared to the recent results obtained using GATE 8.1 code and published by the OpenDose collaboration. It is shown that the obtained results are in well-agreement with the reference values, with absolute discrepancies less than 0.6% for a self-absorption condition and less than 5% in almost all energies for a cross-absorption condition. We concluded that InterDosi code might be used for dosimetry of internal electron emitters.


Assuntos
Imagens de Fantasmas , Doses de Radiação , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador , Adulto , Feminino , Humanos , Método de Monte Carlo , Medicina Nuclear , Proteção Radiológica , Valores de Referência
6.
Radiat Environ Biophys ; 61(1): 111-118, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34657189

RESUMO

InterDosi is a new in-house Monte Carlo code that aims at facilitating the use of the Geant4 toolkit for internal dosimetry using voxel-based phantoms. In the present work the dosimetric capabilities of this code are assessed by calculating self-irradiation specific absorbed fractions (SI-SAFs) in a voxel-based crab phantom. Recent standard human organ compositions and densities taken from ICRP Publication 110 have been used for material specifications of the four organs of a crab, namely, the heart, hepatopancreas, gills, and gonads, whereas the material assigned to the crab shell has been modeled based on literature values. The SI-SAFs were calculated for mono-energetic photons of energies between 10 and 4000 keV, and for mono-energetic electrons of energies between 100 and 4000 keV. The statistical errors corresponding to the calculated SI-SAFs were all less than 0.01%. The results obtained demonstrate that the simulated masses and volumes of the crab organs are in good agreement with those presented in the literature. In addition, the dosimetric results show that the calculated SI-SAFs are generally consistent with those reported in the literature, with some moderate differences due to differences in material specification. It is concluded that the InterDosi code can be successfully employed in internal dose estimations in small organisms, and it is suggested that material specifications specifically relating to crab tissues should be developed to provide more precise SI-SAFs.


Assuntos
Braquiúros , Fótons , Animais , Elétrons , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Doses de Radiação , Radiometria/métodos
7.
Appl Radiat Isot ; 176: 109838, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34175546

RESUMO

In this work we used the InterDosi code to estimate photon specific absorbed fractions (SAFs) for some organs of the Zubal adult male voxelized phantom. Chemical compositions and densities of ICRP 110 adult male organs were attributed to those of the studied voxelized phantom. The SAFs of monoenergetic photons with energies ranging from 0.01 to 2 MeV, were calculated for three target regions, namely kidneys, liver, and spleen, which were the radiation source regions too. The obtained SAFs were compared to recent results obtained with the GATE code. In the GATE study, chemical compositions and densities of different organs were obtained from the ICRU report number 44. The inter-comparisons between the two studies show reasonably similar results, as 80% of the calculated SAFs are consistent within 2.5% discrepancy. This demonstrates the usefulness and applicability of the InterDosi code for internal dose calculations in a voxel-based phantom. We completed this work by studying the alpha SAFs in some organs for energies emitted by 213Bi used in targeted alpha-therapy and an analytical formula was derived for rapid alpha self-irradiation calculation in soft tissues.


Assuntos
Partículas alfa , Imagens de Fantasmas , Fótons , Doses de Radiação , Adulto , Humanos , Masculino , Método de Monte Carlo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA