Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Acad Radiol ; 30(5): 873-880, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-35811218

RESUMO

RATIONALE AND OBJECTIVES: This study aimed to explore the effect of iron deposition on native T1 mapping and blood oxygen level-dependent (BOLD) imaging in detecting liver fibrosis (LF) in a rabbit model. MATERIALS AND METHODS: An LF group (n = 100) was established by subcutaneously injecting 50% carbon tetrachloride (CCl4) oil solution, and 20 normal rabbits composed a control group. Native T1 mapping and BOLD were performed, and the T1native and R2* quantitative parameters were analyzed by receiver operating characteristic (ROC) and multiple logistic regression analyses, with histopathological results and liver iron content (LIC) serving as reference standards. RESULTS: In total, 18, 17, 16, 18, and 15 rabbits were histopathologically diagnosed with LF stages F0, F1, F2, F3, and F4, respectively. T1native (r = 0.47), R2* (r = 0.75) and LIC (r = 0.61) increased with LF stage progression (p < 0.001). Compared to T1native values, R2* performed better in diagnosing the LF stage, especially for distinguishing F1-F2 from F3-F4 (AUC = 0.66 vs. 0.91, p = 0.01). Combined with the LIC, both T1native and R2* showed improved diagnostic value in comparison to the individual imaging techniques, particularly for diagnosing F0 vs. F1-F2 and F0 vs. F1-F4, with AUC values of 0.90 vs. 0.70 (p = 0.01) and 0.93 vs. 0.77 (p = 0.01) for T1native + LIC vs. LIC, respectively. CONCLUSION: BOLD imaging performed better than native T1 mapping in predicting and diagnosing LF stage progression. The decrease in diagnostic accuracy caused by the deposition of liver iron is a potential pitfall in the assessment of LF with BOLD imaging and native T1 mapping.


Assuntos
Tetracloreto de Carbono , Saturação de Oxigênio , Animais , Coelhos , Tetracloreto de Carbono/toxicidade , Cirrose Hepática/induzido quimicamente , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Fígado/diagnóstico por imagem , Fígado/patologia , Imageamento por Ressonância Magnética/métodos
2.
Magn Reson Imaging ; 70: 57-63, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32325235

RESUMO

PURPOSE: To explore quantitative parameters obtained by dynamic contrast-enhanced magnetic resonance imaging (DCE MRI) with Gd-EOB-DTPA in discriminating early-stage liver fibrosis (LF) in a rabbit model. MATERIALS AND METHODS: LF was established in 60 rabbits by the injection of 50% CCl4 oil solution, whereas 30 rabbits served as the control group. All rabbits underwent pathological examination to determine the LF stage using the METAVIR classification system. DCE MRI was performed, and quantitative parameters, including Ktrans, Kep, Ve, Vp and Re were measured and evaluated among the different LF stages using spearman correlation coefficients and receiver operating characteristic curve. RESULTS: In all, 24, 25, and 22 rabbits had stage F0, stage F1, and stage F2 LF, respectively. Ktrans (r = 0.803) increased, and Kep (r = -0.495) and Re (r = -0.701) decreased with LF stage progression (P < 0.001), while no significant correlation was found for Ve or Vp. Ktrans and Re were significantly different between all LF stage pairs compared (F0 vs. F1, F0 vs. F2, F1 vs. F2, F0 vs. F1-F2, P < 0.05). With the exception of F0 vs. F1, Kep differed significantly between stages (P < 0.05). The AUC of Ktrans was higher than that of other quantitative parameters, with an AUC of 0.92, 0.99, 0.94 and 0.92 for staging F0 vs. F1, F0 vs. F2, F1 vs. F2, and F0 vs. F1-F2, respectively. CONCLUSION: Among quantitative parameters of Gd-EOB-DTPA DCE MRI, Ktrans was the best predictor for quantitatively differentiating early-stage LF.


Assuntos
Tetracloreto de Carbono/toxicidade , Meios de Contraste , Gadolínio DTPA , Cirrose Hepática/induzido quimicamente , Cirrose Hepática/diagnóstico por imagem , Imageamento por Ressonância Magnética , Animais , Cirrose Hepática/patologia , Masculino , Curva ROC , Coelhos
3.
J Magn Reson Imaging ; 47(6): 1572-1577, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29236342

RESUMO

BACKGROUND: Previous studies indicated that two-dimensional-susceptibility weighted imaging (2D-SWI) could serve as a useful biomarker for differentiating the grade of liver fibrosis. PURPOSE: To evaluate the feasibility of 2D-SWI in the dynamic quantification of renal fibrosis in a rabbit model. STUDY TYPE: Longitudinal study. ANIMAL MODEL: Twenty-Four New Zealand White Rabbits including control group (n = 4); and renal fibrosis group (n = 20), by means of a unilateral ureteral obstruction (UUO) model. FIELD STRENGTH/SEQUENCE: The 3.0 T SWI using a 2D gradient-echo sequence. ASSESSMENT: The relative SWI signal ratio(r) of cortical and medulla (r = SIrenal /SImuscle ) was longitudinally assessed before ligation and on weeks 2, 4, 6, and 8 following ligation. Sirius Red staining was used to assess the degree of fibrosis in five high-power fields. STATISTICAL TESTS: The repeated measures of analysis of variance and linear regression analysis. RESULTS: Both the cortical and medullary r values were significantly higher in the UUO kidneys at week 2 compared with the kidneys before ligation. Over the course of UUO progression, significant changes occurred in the cortical and medullary r values in vivo and fibrosis scores in vitro (all P values < 0.05). The r values gradually decreased, while the fibrosis scores gradually increased over 8 weeks following ligation. The linear regression analysis showed a strong and significant correlation between cortical and medullary r values and the pathologic fibrosis scores (R2 = 0.91, 0.81, respectively). DATA CONCLUSION: The SWI sequence could provide a quantitative evaluation of renal fibrosis during UUO progression. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:1572-1577.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Nefropatias/diagnóstico por imagem , Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética , Ureter/diagnóstico por imagem , Obstrução Ureteral/patologia , Animais , Artefatos , Modelos Animais de Doenças , Progressão da Doença , Fibrose , Rim/patologia , Nefropatias/patologia , Modelos Lineares , Estudos Longitudinais , Masculino , Coelhos , Ureter/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA