Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
Int J Cardiol ; 402: 131832, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38316189

RESUMO

BACKGROUND: The microvascular resistance reserve (MRR) is an innovative index to assess the vasodilatory capacity of the coronary circulation while accounting for the presence of concomitant epicardial disease. The MRR has shown to be a valuable diagnostic and prognostic tool in the general coronary artery disease (CAD) population. However, considering the fundamental aspects of its assessment and the unique hemodynamic characteristics of women, it is crucial to provide additional considerations for evaluating the MRR specifically in women. AIM: The aim of this study was to assess the diagnostic and prognostic applicability of the MRR in women and assess the potential differences across different sexes. METHODS: From the ILIAS Registry, we enrolled all patients with a stable indication for invasive coronary angiography, ensuring complete physiological and follow-up data. We analyzed the diagnostic value by comparing differences between sexes and evaluated the prognostic value of the MRR specifically in women, comparing it to that in men. RESULTS: A total of 1494 patients were included of which 26% were women. The correlation between MRR and CFR was good and similar between women (r = 0.80, p < 0.005) and men (r = 0.81, p < 0.005). The MRR was an independent and important predictor of MACE in both women (HR 0.67, 0.47-0.96, p = 0.027) and men (HR 0.84, 0.74-0.95, p = 0.007). The optimal cut-off value for MRR in women was 2.8 and 3.2 in men. An abnormal MRR similarly predicted MACE at 5-year follow-up in both women and men. CONCLUSION: The MRR seems to be equally applicable in both women and men with stable coronary artery disease.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Masculino , Humanos , Feminino , Doença da Artéria Coronariana/diagnóstico por imagem , Circulação Coronária/fisiologia , Angiografia Coronária , Prognóstico , Hemodinâmica , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Vasos Coronários/diagnóstico por imagem
2.
JACC Cardiovasc Interv ; 15(10): 1047-1056, 2022 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-35589234

RESUMO

OBJECTIVES: The aim of this study was to demonstrate the clinical implications of combined assessment of fractional flow reserve (FFR) and coronary flow reserve (CFR). BACKGROUND: Combined assessment of FFR and CFR allows detailed characterization of pathophysiology in chronic coronary syndromes. Data on the clinical implications of distinct FFR and CFR patterns are limited, leading to uncertainty regarding their relevance. METHODS: Patients with chronic coronary syndromes and obstructive coronary artery disease were selected from the multicenter ILIAS (Inclusive Invasive Physiological Assessment in Angina Syndromes) registry. Patients were classified into 4 groups on the basis of FFR ≤0.80 and CFR <2.0. The endpoint was the 5-year target vessel failure (TVF) rate. RESULTS: A total of 2,143 patients with 2,725 lesions were included. Compared with normal FFR/normal CFR, low FFR/low CFR carried the highest risk for TVF (HR: 5.4; 95% CI: 3.2-9.3; P < 0.001), significantly higher than in revascularized vessels (P = 0.007). Discordance, with either low FFR/normal CFR or normal FFR/low CFR, was associated with increased TVF rates compared with normal FFR/normal CFR (low FFR/normal CFR: HR: 3.5 [95% CI: 2.2-5.4; P < 0.001]; normal FFR/low CFR: HR: 3.0 [95% CI: 1.9-4.7; P < 0.001]). No difference in 5-year TVF was observed between the 2 discordant groups (P = 0.57) or between the discordant groups and the revascularized group (P = 0.26 vs low FFR/normal CFR; P = 0.60 vs normal FFR/low CFR). CONCLUSIONS: Impaired coronary hemodynamics are uniformly associated with increased 5-year TVF rates. Nonrevascularized vessels with discordant FFR and CFR are associated with 5-year event rates that are equivalent to those of vessels that undergo revascularization, whereas vessels with combined low FFR and CFR exhibit event rates that are significantly higher than after revascularization. (Inclusive Invasive Physiological Assessment in Angina Syndromes Registry [ILIAS Registry]; NCT04485234).


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Tomada de Decisões , Humanos , Valor Preditivo dos Testes , Sistema de Registros , Fatores de Risco , Síndrome , Fatores de Tempo , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 99(7): 2018-2025, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35366386

RESUMO

BACKGROUND: The index of microvascular resistance (IMR) is an established tool to assess the status of coronary microcirculation. However, the need for a pressure wire and hyperemic agents have limited its routine use and have led to the development of angiography-derived pressure-wire-free methods (angiography-derived IMR [IMRAngio]). In this review and meta-analysis, we aim to assess the global diagnosis accuracy of IMRAngio versus IMR. METHODS: A systematic review of the literature was performed. Studies directly evaluating IMRAngio versus IMR were considered eligible. Pooled values of diagnostic test and summary receiver operator curve were calculated. RESULTS: Seven studies directly comparing IMRAngio versus IMR were included (687 patients; 807 vessels). Pooled sensitivity, specificity, +likelihood ratio (LR), and -LR were 82%, 83%, 4.5, and 0.26 respectively. Pooled accuracy was 83% while pooled positive predictive value and negative predictive value were 76% and 85%, respectively. Comparable results were obtained when analyzing by clinical scenario (acute and nonacute coronary syndromes). CONCLUSION: IMRAngio shows a good diagnostic performance for the prediction of abnormal IMR.


Assuntos
Circulação Coronária , Vasos Coronários , Angiografia Coronária , Vasos Coronários/diagnóstico por imagem , Humanos , Microcirculação , Valor Preditivo dos Testes , Resultado do Tratamento , Resistência Vascular
4.
EuroIntervention ; 17(15): 1260-1270, 2022 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-34338643

RESUMO

BACKGROUND: Coronary blood flow in humans is known to be predominantly diastolic. Small studies in animals and humans suggest that this is less pronounced or even reversed in the right coronary artery (RCA). AIMS: This study aimed to characterise the phasic patterns of coronary flow in the left versus right coronary arteries of patients undergoing invasive physiological assessment. METHODS: We analysed data from the Iberian-Dutch-English Collaborators (IDEAL) study. A total of 482 simultaneous pressure and flow measurements from 301 patients were included in our analysis. RESULTS: On average, coronary flow was higher in diastole both at rest and during hyperaemia in both the RCA and LCA (mean diastolic-to-systolic velocity ratio [DSVR] was, respectively, 1.85±0.70, 1.76±0.58, 1.53±0.34 and 1.58±0.43 for LCArest, LCAhyp, RCArest and RCAhyp, p<0.001 for between-vessel comparisons). Although the type of RCA dominance affected the DSVR magnitude (RCAdom=1.55±0.35, RCAco-dom=1.40±0.27, RCAnon-dom=1.35; standard deviation not reported as n=3), systolic flow was very rarely predominant (DSVR was greater than or equal to 1.00 in 472/482 cases [97.9%] overall), with equal prevalence in the LCA. Stenosis severity or microvascular dysfunction had a negligible impact on DSVR in both the RCA and LCA (DSVR x hyperaemic stenosis resistance R2 =0.018, p=0.03 and DSVR x coronary flow reserve R2 <0.001, p=0.98). CONCLUSIONS: In patients with coronary artery disease undergoing physiological assessment, diastolic flow predominance is seen in both left and right coronary arteries. Clinical interpretation of coronary physiological data should therefore not differ between the left and the right coronary systems.


Assuntos
Vasos Coronários , Hiperemia , Velocidade do Fluxo Sanguíneo/fisiologia , Constrição Patológica , Circulação Coronária/fisiologia , Vasos Coronários/diagnóstico por imagem , Diástole , Humanos
5.
Circ Cardiovasc Interv ; 13(1): e007893, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31870178

RESUMO

BACKGROUND: Intravenous infusion of adenosine is considered standard practice for fractional flow reserve (FFR) assessment but is associated with adverse side-effects and is time-consuming. Intracoronary bolus injection of adenosine is better tolerated by patients, cheaper, and less time-consuming. However, current literature remains fragmented and modestly sized regarding the equivalence of intracoronary versus intravenous adenosine. We aim to investigate the relationship between intracoronary adenosine and intravenous adenosine to determine FFR. METHODS: We performed a lesion-level meta-analysis to compare intracoronary adenosine with intravenous adenosine (140 µg/kg per minute) for FFR assessment. The search was conducted in accordance to the Preferred Reporting for Systematic Reviews and Meta-Analysis statement. Lesion-level data were obtained by contacting the respective authors or by digitization of scatterplots using custom-made software. Intracoronary adenosine dose was defined as; low: <40 µg, intermediate: 40 to 99 µg, and high: ≥100 µg. RESULTS: We collected 1972 FFR measurements (1413 lesions) comparing intracoronary with intravenous adenosine from 16 studies. There was a strong correlation (correlation coefficient =0.915; P<0.001) between intracoronary-FFR and intravenous-FFR. Mean FFR was 0.81±0.11 for intracoronary adenosine and 0.81±0.11 for intravenous adenosine (P<0.001). We documented a nonclinically relevant mean difference of 0.006 (limits of agreement: -0.066 to 0.078) between the methods. When stratified by the intracoronary adenosine dose, mean differences between intracoronary and intravenous-FFR amounted to 0.004, 0.011, or 0.000 FFR units for low-dose, intermediate-dose, and high-dose intracoronary adenosine, respectively. CONCLUSIONS: The present study documents clinically irrelevant differences in FFR values obtained with intracoronary versus intravenous adenosine. Intracoronary adenosine hence confers a practical and patient-friendly alternative for intravenous adenosine for FFR assessment.


Assuntos
Adenosina/administração & dosagem , Cateterismo Cardíaco , Doença da Artéria Coronariana/diagnóstico , Reserva Fracionada de Fluxo Miocárdico , Vasodilatadores/administração & dosagem , Adenosina/efeitos adversos , Doença da Artéria Coronariana/fisiopatologia , Humanos , Infusões Intravenosas , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Vasodilatadores/efeitos adversos
6.
EuroIntervention ; 13(6): 666-679, 2017 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-28844029

RESUMO

The pressure wire has revolutionised cardiology by moving the focus of revascularisation from anatomy to physiology. This review provides a comprehensive viewpoint on the foundations of the field of intracoronary physiology, with emphasis on the development and clinical evidence of fractional flow reserve (FFR). Additionally, we critically appraise clinical decision making based on the evolving area of resting coronary physiology. The emerging role of coronary flow reserve and its complementariness with FFR is also discussed, and the importance of the invasive assessment of the coronary microcirculation in outlining prognosis is put into perspective. Overall, this review summarises the capacity of invasive coronary physiology indices to guide revascularisation and to discriminate patients at high risk of an adverse cardiovascular outcome.


Assuntos
Angiografia Coronária , Estenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Cateterismo Cardíaco/métodos , Angiografia Coronária/métodos , Circulação Coronária/fisiologia , Estenose Coronária/diagnóstico por imagem , Humanos
7.
EuroIntervention ; 13(8): 944-952, 2017 10 20.
Artigo em Inglês | MEDLINE | ID: mdl-28485281

RESUMO

AIMS: The index of microcirculatory resistance (IMR) is increasingly used to quantify microcirculatory function. However, in normal coronary arteries, resistance increases with the branching structure of the coronary tree, which suggests that IMR could be influenced by the amount of downstream myocardial mass (MM). We aimed to evaluate the influence of the amount of MM subtended to an intermediate stenosis on the IMR. METHODS AND RESULTS: IMR, fractional flow reserve and coronary flow reserve (CFR) were measured in 123 coronary arteries (102 patients) with intermediate stenosis. Jeopardised MM was estimated with the Myocardial Jeopardy Index (MJI). MM was inversely associated with IMR (R.


Assuntos
Doença da Artéria Coronariana/fisiopatologia , Estenose Coronária/fisiopatologia , Microcirculação/fisiologia , Resistência Vascular/fisiologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Humanos , Masculino , Isquemia Miocárdica/fisiopatologia
8.
Rev Port Cardiol ; 36(4): 311.e1-311.e3, 2017 Apr.
Artigo em Inglês, Português | MEDLINE | ID: mdl-28342663

RESUMO

A 62-year-old woman was admitted with chest pain of two hours' duration, ECG changes in the precordial leads and left ventricular ejection fraction of 30% on the echocardiogram. Emergent catheterization demonstrated severe flow disturbance in the left coronary artery. An intra-aortic balloon pump and a drug-eluting stent were implanted. However, the flow disturbance persisted. Optical coherence tomography followed by intravascular ultrasound provided crucial data on the mechanism and helped to optimize treatment in this critical patient.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Hematoma/diagnóstico por imagem , Feminino , Humanos , Pessoa de Meia-Idade , Imagem Multimodal
9.
Eur Heart J ; 37(26): 2069-80, 2016 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-26612582

RESUMO

BACKGROUND: Our understanding of human coronary physiological behaviour is derived from animal models. We sought to describe physiological behaviour across a large collection of invasive pressure and flow velocity measurements, to provide a better understanding of the relationships between these physiological parameters and to evaluate the rationale for resting stenosis assessment. METHODS AND RESULTS: Five hundred and sixty-seven simultaneous intracoronary pressure and flow velocity assessments from 301 patients were analysed for coronary flow velocity, trans-stenotic pressure gradient (TG), and microvascular resistance (MVR). Measurements were made during baseline and hyperaemic conditions. The whole cardiac cycle and the diastolic wave-free period were assessed. Stenoses were assessed according to fractional flow reserve (FFR) and quantitative coronary angiography DS%. With progressive worsening of stenoses, from unobstructed angiographic normal vessels to those with FFR ≤ 0.50, hyperaemic flow falls significantly from 45 to 19 cm/s, Ptrend < 0.001 in a curvilinear pattern. Resting flow was unaffected by stenosis severity and was consistent across all strata of stenosis (Ptrend > 0.05 for all). Trans-stenotic pressure gradient rose with stenosis severity for both rest and hyperaemic measures (Ptrend < 0.001 for both). Microvascular resistance declines with stenosis severity under resting conditions (Ptrend < 0.001), but was unchanged at hyperaemia (2.3 ± 1.1 mmHg/cm/s; Ptrend = 0.19). CONCLUSIONS: With progressive stenosis severity, TG rises. However, while hyperaemic flow falls significantly, resting coronary flow is maintained by compensatory reduction of MVR, demonstrating coronary auto-regulation. These data support the translation of coronary physiological concepts derived from animals to patients with coronary artery disease and furthermore, suggest that resting pressure indices can be used to detect the haemodynamic significance of coronary artery stenoses.


Assuntos
Constrição Patológica , Velocidade do Fluxo Sanguíneo , Angiografia Coronária , Circulação Coronária , Estenose Coronária , Vasos Coronários , Reserva Fracionada de Fluxo Miocárdico , Humanos
10.
JACC Cardiovasc Interv ; 8(13): 1681-91, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26585618

RESUMO

OBJECTIVES: This study sought to understand the physiological basis of baseline distal-to-aortic pressure ratio (Pd/Pa) and fractional flow reserve (FFR) agreement and discordance, using coronary flow reserve (CFR), stenosis resistance, and microcirculatory resistance measurements, and form there, to investigate the potential value of combining Pd/Pa with FFR in the diagnostic rationale. BACKGROUND: Pd/Pa is always available before FFR assessment, and emerging data supports the notion that baseline indices can determine the ischemic potential of coronary stenosis in selected subsets. METHODS: A total of 467 stenosed vessels from 363 patients were investigated with pressure and flow sensors during baseline and hyperemia: 168 vessels (135 patients) with thermodilution-derived flow, and 299 vessels (228 patients) with Doppler-derived flow. RESULTS: Pd/Pa correlated more strongly with CFR than FFR (ρ difference = 0.129; p for ρ comparison <0.001). Although Pd/Pa and FFR were closely correlated (ρ = 0.798; 95% confidence interval: 0.767 to 0.828), categorical discordance was observed in 19.3% of total vessels. Such discordance was associated with the patients' clinical profile and was characterized by contrastive changes in stenosis resistance, microcirculatory resistance, and the underlying CFR. Notably, all stenosis with Pd/Pa ≤0.83 (n = 74, 15.8%) progressed to FFR ≤0.80, and although no Pd/Pa cutoff was able to exclude the development of FFR ≤0.80 in the high end of values, only 15 (10.1%) vessels with Pd/Pa ≥0.96 (n = 149, 31.9%) developed FFR ≤0.80, from which none had definite ischemia, as defined by CFR ≤1.74. CONCLUSIONS: Combining baseline Pd/Pa with FFR seems to provide a more comprehensive physiological examination of stenosed coronary arteries and a closer pressure-based appraisal of the flow reserve of the downstream myocardial bed.


Assuntos
Aorta/fisiopatologia , Pressão Arterial , Estenose Coronária/diagnóstico , Vasos Coronários/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico , Idoso , Aorta/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Angiografia Coronária , Estenose Coronária/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Ecocardiografia Doppler , Feminino , Humanos , Hiperemia/fisiopatologia , Masculino , Microcirculação , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Índice de Gravidade de Doença , Termodiluição , Transdutores de Pressão , Resistência Vascular
11.
Circ Cardiovasc Interv ; 8(11): e002857, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26499500

RESUMO

BACKGROUND: The index of microcirculatory resistance (IMR) is a quantitative and specific index for coronary microcirculation. However, the distribution and determinants of IMR have not been fully investigated in patients with ischemic heart disease (IHD). METHODS AND RESULTS: Consecutive patients who underwent elective measurement of both fractional flow reserve (FFR) and IMR were enrolled from 8 centers in 5 countries. Patients with acute myocardial infarction were excluded. To adjust for the influence of collateral flow, IMR values were corrected with Yong's formula (IMRcorr). High IMR was defined as greater than the 75th percentile in each of the major coronary arteries. FFR≤0.80 was defined as an ischemic value. 1096 patients with 1452 coronary arteries were analyzed (mean age 61.1, male 71.2%). Mean FFR was 0.84 and median IMRcorr was 16.6 U (Q1, Q3 12.4 U, 23.0 U). There was no correlation between IMRcorr and FFR values (r=0.01, P=0.62), and the categorical agreement of FFR and IMRcorr was low (kappa value=-0.04, P=0.10). There was no correlation between IMRcorr and angiographic % diameter stenosis (r=-0.03, P=0.25). Determinants of high IMR were previous myocardial infarction (odds ratio [OR] 2.16, 95% confidence interval [CI] 1.24-3.74, P=0.01), right coronary artery (OR 2.09, 95% CI 1.54-2.84, P<0.01), female (OR 1.67, 95% CI 1.18-2.38, P<0.01), and obesity (OR 1.80, 95% CI 1.31-2.49, P<0.01). Determinants of FFR ≤0.80 were left anterior descending coronary artery (OR 4.31, 95% CI 2.92-6.36, P<0.01), angiographic diameter stenosis ≥50% (OR 5.16, 95% CI 3.66-7.28, P<0.01), male (OR 2.15, 95% CI 1.38-3.35, P<0.01), and age (per 10 years, OR 1.21, 95% CI 1.01-1.46, P=0.04). CONCLUSIONS: IMR showed no correlation with FFR and angiographic lesion severity, and the predictors of high IMR value were different from those for ischemic FFR value. Therefore, integration of IMR into FFR measurement may provide additional insights regarding the relative contribution of macro- and microvascular disease in patients with ischemic heart disease. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT02186093.


Assuntos
Constrição Patológica/diagnóstico , Vasos Coronários/metabolismo , Microcirculação , Isquemia Miocárdica/diagnóstico , Resistência Vascular , Idoso , Circulação Colateral , Vasos Coronários/patologia , Feminino , Reserva Fracionada de Fluxo Miocárdico , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico
12.
JACC Cardiovasc Interv ; 8(6): 824-833, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25999106

RESUMO

OBJECTIVES: The purpose of this study was to assess the diagnostic accuracy of the instantaneous wave-free ratio (iFR) to characterize, outside of a pre-specified range of values, stenosis severity, as defined by fractional flow reserve (FFR) ≤0.80, in a prospective, independent, controlled, core laboratory-based environment. BACKGROUND: Studies with methodological heterogeneity have reported some discrepancies in the classification agreement between iFR and FFR. The ADVISE II (ADenosine Vasodilator Independent Stenosis Evaluation II) study was designed to overcome limitations of previous iFR versus FFR comparisons. METHODS: A total of 919 intermediate coronary stenoses were investigated during baseline and hyperemia. From these, 690 pressure recordings (n = 598 patients) met core laboratory physiology criteria and are included in this report. RESULTS: The pre-specified iFR cut-off of 0.89 was optimal for the study and correctly classified 82.5% of the stenoses, with a sensitivity of 73.0% and specificity of 87.8% (C statistic: 0.90 [95% confidence interval (CI): 0.88 to 0.92, p < 0.001]). The proportion of stenoses properly classified by iFR outside of the pre-specified treatment (≤0.85) and deferral (≥0.94) values was 91.6% (95% CI: 88.8% to 93.9%). When combined with FFR use within these cut-offs, the percent of stenoses properly classified by such a pre-specified hybrid iFR-FFR approach was 94.2% (95% CI: 92.2% to 95.8%). The hybrid iFR-FFR approach obviated vasodilators from 65.1% (95% CI: 61.1% to 68.9%) of patients and 69.1% (95% CI: 65.5% to 72.6%) of stenoses. CONCLUSIONS: The ADVISE II study supports, on the basis rigorous methodology, the diagnostic value of iFR in establishing the functional significance of coronary stenoses, and highlights its complementariness with FFR when used in a hybrid iFR-FFR approach. (ADenosine Vasodilator Independent Stenosis Evaluation II-ADVISE II; NCT01740895).


Assuntos
Adenosina/administração & dosagem , Cateterismo Cardíaco , Estenose Coronária/diagnóstico , Reserva Fracionada de Fluxo Miocárdico , Vasodilatadores/administração & dosagem , Idoso , Algoritmos , Angiografia Coronária , Estenose Coronária/classificação , Estenose Coronária/fisiopatologia , Eletrocardiografia , Feminino , Hemodinâmica , Humanos , Hiperemia/fisiopatologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Processamento de Sinais Assistido por Computador
14.
EuroIntervention ; 10(5): 574-83, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24988003

RESUMO

AIMS: To develop a simplified approach of virtual functional assessment of coronary stenosis from routine angiographic data and test it against fractional flow reserve using a pressure wire (wire-FFR). METHODS AND RESULTS: Three-dimensional quantitative coronary angiography (3D-QCA) was performed in 139 vessels (120 patients) with intermediate lesions assessed by wire-FFR (reference standard: ≤0.80). The 3D-QCA models were processed with computational fluid dynamics (CFD) to calculate the lesion-specific pressure gradient (ΔP) and construct the ΔP-flow curve, from which the virtual functional assessment index (vFAI) was derived. The discriminatory power of vFAI for ischaemia- producing lesions was high (area under the receiver operator characteristic curve [AUC]: 92% [95% CI: 86-96%]). Diagnostic accuracy, sensitivity and specificity for the optimal vFAI cut-point (≤0.82) were 88%, 90% and 86%, respectively. Virtual-FAI demonstrated superior discrimination against 3D-QCA-derived % area stenosis (AUC: 78% [95% CI: 70- 84%]; p<0.0001 compared to vFAI). There was a close correlation (r=0.78, p<0.0001) and agreement of vFAI compared to wire-FFR (mean difference: -0.0039±0.085, p=0.59). CONCLUSIONS: We developed a fast and simple CFD-powered virtual haemodynamic assessment model using only routine angiography and without requiring any invasive physiology measurements/hyperaemia induction. Virtual-FAI showed a high diagnostic performance and incremental value to QCA for predicting wire-FFR; this "less invasive" approach could have important implications for patient management and cost.


Assuntos
Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Modelos Cardiovasculares , Idoso , Simulação por Computador , Estenose Coronária/fisiopatologia , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
15.
Heart ; 100(12): 951-9, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24727867

RESUMO

BACKGROUND: Fractional flow reserve (FFR) aims to identify the extent of epicardial disease, but may be obscured by involvement of the coronary microvasculature. We documented the impact of hyperaemic stenosis resistance (HSR) and hyperaemic microvascular resistance (HMR) on FFR, and its relationship with myocardial ischaemia in patients with stable coronary artery disease. METHODS AND RESULTS: We evaluated 255 coronary arteries with stenoses of intermediate severity by means of intracoronary pressure and flow measurements to determine FFR, HSR and HMR. Myocardial perfusion scintigraphy (MPS) was performed to identify inducible myocardial ischaemia. In 178 patients, HMR was additionally determined in a reference coronary artery. Target vessel HMR was stratified according to reference vessel HMR tertiles. The diagnostic OR for inducible ischaemia on MPS of a positive compared with a negative FFR was significantly higher only in the presence of a high HMR (at the 0.75 and 0.80 FFR cut-off). Among stenoses with a positive FFR, the prevalence of ischaemia was significantly higher when HMR was high despite equivalent FFR across the HMR groups. This was paralleled by a concomitant significant increase in HSR with increasing HMR across groups. The relation between FFR and HSR (r(2)=0.54, p<0.001) was modulated by the magnitude of HMR, and improved substantially after adjustment for HMR (adjusted-r(2)=0.73, p<0.001), where, for epicardial disease of equivalent severity, FFR increased with increasing HMR. CONCLUSIONS: Identification of epicardial disease severity by FFR is partly obscured by the microvascular resistance, which illustrates the necessity of combined pressure and flow measurements in daily practice.


Assuntos
Doença da Artéria Coronariana/fisiopatologia , Estenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico , Hiperemia/fisiopatologia , Microcirculação , Resistência Vascular , Adenosina , Idoso , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Cateterismo Cardíaco , Distribuição de Qui-Quadrado , Doença da Artéria Coronariana/diagnóstico , Estenose Coronária/diagnóstico , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio , Valor Preditivo dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Vasodilatadores
16.
Circ Cardiovasc Interv ; 7(1): 35-42, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24399244

RESUMO

BACKGROUND: Intravenous adenosine infusion produces coronary and systemic vasodilatation, generally leading to systemic hypotension. However, adenosine-induced hypotension during stable hyperemia is heterogeneous, and its relevance to coronary stenoses assessment with fractional flow reserve (FFR) remains largely unknown. METHODS AND RESULTS: FFR, coronary flow reserve, and index of microcirculatory resistance were measured in 93 stenosed arteries (79 patients). Clinical and intracoronary measurements were analyzed among tertiles of the percentage degree of adenosine-induced hypotension, defined as follows: %ΔP(a)=-[100-(hyperemic aortic pressure×100/baseline aortic pressure)]. Overall, %ΔP(a) was -13.6±12.0%. Body mass index was associated with %ΔP(a) (r=0.258; P=0.025) and obesity, an independent predictor of profound adenosine-induced hypotension (tertile 3 of %ΔP(a); odds ratio, 3.95 [95% confidence interval, 1.48-10.54]; P=0.006). %ΔP(a) was associated with index of microcirculatory resistance (ρ=0.311; P=0.002), coronary flow reserve (r=-0.246; P=0.017), and marginally with FFR (r=0.203; P=0.051). However, index of microcirculatory resistance (ß=0.003; P<0.001) and not %ΔP(a) (ß=-0.001; P=0.564) was a predictor of FFR. Compared with tertiles 1 and 2 of %ΔP(a) (n=62 [66.6%]), stenoses assessed during profound adenosine-induced hypotension (n=31 [33.3%]) had lower index of microcirculatory resistance (12.4 [8.6-22.7] versus 20 [15.8-35.5]; P=0.001) and FFR values (0.77±0.13 versus 0.83±0.12; P=0.021), as well as a nonsignificant increase in coronary flow reserve (2.5±1.1 versus 2.2±0.87; P=0.170). CONCLUSIONS: The modification of systemic blood pressure during intravenous adenosine infusion is related to hyperemic microcirculatory resistance in the heart. Profound adenosine-induced hypotension is associated with obesity, lower coronary microcirculatory resistance, and lower FFR values.


Assuntos
Adenosina/administração & dosagem , Estenose Coronária/diagnóstico , Hipotensão/diagnóstico , Vasodilatadores/administração & dosagem , Adenosina/efeitos adversos , Idoso , Velocidade do Fluxo Sanguíneo/efeitos dos fármacos , Índice de Massa Corporal , Estenose Coronária/complicações , Reserva Fracionada de Fluxo Miocárdico/efeitos dos fármacos , Humanos , Hipotensão/etiologia , Infusões Intravenosas , Masculino , Microcirculação/efeitos dos fármacos , Pessoa de Meia-Idade , Fatores de Risco , Resistência Vascular/efeitos dos fármacos , Vasodilatadores/efeitos adversos
17.
Circ Cardiovasc Interv ; 6(6): 654-61, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24254709

RESUMO

BACKGROUND: We studied the hemodynamic response to intravenous adenosine on calculation of fractional flow reserve (FFR). Intravenous adenosine is widely used to achieve conditions of stable hyperemia for measurement of FFR. However, intravenous adenosine affects both systemic and coronary vascular beds differentially. METHODS AND RESULTS: A total of 283 patients (310 coronary stenoses) underwent coronary angiography with FFR using intravenous adenosine 140 mcg/kg per minute via a central femoral vein. Offline analysis was performed to calculate aortic (Pa), distal intracoronary (Pd), and reservoir (Pr) pressure at baseline, peak, and stable hyperemia. Seven different hemodynamic patterns were observed according to Pa and Pd change at peak and stable hyperemia. The average time from baseline to stable hyperemia was 68.2±38.5 seconds, when both ΔPa and ΔPd were decreased (ΔPa, -10.2±10.5 mm Hg; ΔPd, -18.2±10.8 mm Hg; P<0.001 for both). The fall in Pa closely correlated with the reduction in peripheral Pr (ΔPr, -12.9±15.7 mm Hg; P<0.001; r=0.9; P<0.001). ΔPa and ΔPd were closely related under conditions of peak (r=0.75; P<0.001) and stable hyperemia (r=0.83; P<0.001). On average, 56% (10.2 mm Hg) of the reduction in Pd was because of fall in Pa. FFR lesion classification changed in 9% using an FFR threshold of ≤0.80 and 5.2% with FFR threshold <0.75 when comparing Pd/Pa at peak and stable hyperemia. CONCLUSIONS: Intravenous adenosine results in variable changes in systemic blood pressure, which can lead to alterations in FFR lesion classification. Attention is required to ensure FFR is measured under conditions of stable hyperemia, although the FFR value at this point may be numerically higher.


Assuntos
Adenosina/administração & dosagem , Adenosina/farmacologia , Estenose Coronária/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico/efeitos dos fármacos , Hemodinâmica/efeitos dos fármacos , Índice de Gravidade de Doença , Administração Intravenosa , Idoso , Aorta/efeitos dos fármacos , Aorta/fisiologia , Pressão Sanguínea/efeitos dos fármacos , Pressão Sanguínea/fisiologia , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/efeitos dos fármacos , Vasos Coronários/fisiologia , Feminino , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA