Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Int J Radiat Oncol Biol Phys ; 95(3): 1075-1082, 2016 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-27130788

RESUMO

PURPOSE: To use 4-dimensional computed tomography (4D-CT) imaging to predict the level of uncertainty in cardiac dose estimates of the left anterior descending artery that arises due to breathing motion during radiation therapy for left-sided breast cancer. METHODS AND MATERIALS: The fast helical CT (FH-CT) and 4D-CT of 30 left-sided breast cancer patients were retrospectively analyzed. Treatment plans were created on the FH-CT. The original treatment plan was then superimposed onto all 10 phases of the 4D-CT to quantify the dosimetric impact of respiratory motion through 4D dose accumulation (4D-dose). Dose-volume histograms for the heart, left ventricle (LV), and left anterior descending (LAD) artery obtained from the FH-CT were compared with those obtained from the 4D-dose. RESULTS: The 95% confidence interval of 4D-dose and FH-CT differences in mean dose estimates for the heart, LV, and LAD were ±0.5 Gy, ±1.0 Gy, and ±8.7 Gy, respectively. CONCLUSION: Fast helical CT is a good approximation for doses to the heart and LV; however, dose estimates for the LAD are susceptible to uncertainties that arise due to intrafraction breathing motion that cannot be ascertained without the additional information obtained from 4D-CT and dose accumulation. For future clinical studies, we suggest the use of 4D-CT-derived dose-volume histograms for estimating the dose to the LAD.


Assuntos
Vasos Coronários/efeitos da radiação , Fracionamento da Dose de Radiação , Tomografia Computadorizada Quadridimensional/métodos , Órgãos em Risco/efeitos da radiação , Mecânica Respiratória , Neoplasias Unilaterais da Mama/radioterapia , Adulto , Feminino , Humanos , Masculino , Movimento (Física) , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento , Neoplasias Unilaterais da Mama/diagnóstico por imagem
2.
Artigo em Inglês | MEDLINE | ID: mdl-23831525

RESUMO

A sensitive high-performance reverse phase liquid chromatography-positive ion electrospray tandem mass spectrometry method was developed and validated for the quantification of telaprevir and its inactive R-diastereomer (VRT-127394) in human plasma. The analytes and the internal standard (telaprevir-d11) were extracted from plasma by liquid-liquid extraction using tert-Butyl methyl ether (TBME). Chromatographic separation was achieved on a reversed-phase Accucore C18 column with a gradient programme consisting of water:ammonia (25%), 100:0.01 (v/v) (mobile phase A) and ACN:MeOH:ammonia (25%), 15:85:0.01 (v/v/v) (mobile phase B). The MS acquisition was performed with selective reaction monitoring mode using the respective [M+H](+) ions, m/z 680.59→322.42 for telaprevir and VRT-127394, and 691.15→110.13 for telaprevir-d11. The assay exhibited a linear dynamic range of 5-5000ng/mL for telaprevir and VRT-127394. Acceptable precision (%RSD<6.5%) and accuracy (94-108%) were obtained for concentrations over the range of the standard curve. A procedure was established to stabilise the plasma to prevent ex vivo interconversion of the isomers.


Assuntos
Antivirais/sangue , Hepacivirus/enzimologia , Oligopeptídeos/sangue , Inibidores de Proteases/sangue , Espectrometria de Massas por Ionização por Electrospray/métodos , Antivirais/química , Cromatografia Líquida/métodos , Hepatite C/tratamento farmacológico , Humanos , Limite de Detecção , Oligopeptídeos/química , Inibidores de Proteases/química , Estereoisomerismo , Espectrometria de Massas em Tandem/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA